The low pressure side of a refrigeration system is considered to exist from the ().
A

expansion valve to the compressor

B

receiver to the expansion coil

C

expansion valve to the evaporator

D

condenser to the expansion valve


参考答案

参考解析
解析: 暂无解析
更多 “单选题The low pressure side of a refrigeration system is considered to exist from the ().A expansion valve to the compressorB receiver to the expansion coilC expansion valve to the evaporatorD condenser to the expansion valve” 相关考题
考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

考题 What alarm is NOT found on an inert gas system ________.A.Low oxygen alarmB.Low pressure alarmC.Scrubber high water level alarmD.Deck seal low water alarm

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A pressurestatB high pressure cutoutC solenoid valveD low pressure cutout switch

考题 单选题The refrigeration system low pressure cutout switch is actuated by ().A an electric system managerB a sensing bulb at the tail coil of the evaporatorC pressure changes in the suction lineD failure of the king solenoid valve

考题 单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A increaseB reduceC maintain constantD None of the above is true

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A high pressure liquid lineB low pressure liquid lineC high pressure vapor lineD low pressure vapor line

考题 单选题Which cause of following will not lead to refrigeration plant short-cycle?()A lack of refrigerantB refrigerant with much waterC set defectively low pressure relayD no cooling water

考题 单选题Which instrument is used to predict the approach of a low pressure system().A AnemometerB FathometerC BarometerD Thermometer

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().A sub-cooled liquidB high temperature liquidC oil saturated liquidD superheated vapor

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve

考题 单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion