网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The presence of bubbles in a refrigeration system liquid line may ().
A

promote refrigerant dehydration

B

be absorbed in the receiver

C

cause low condensing pressure

D

carry moisture and lead to corrosion


参考答案

参考解析
解析: 暂无解析
更多 “单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion” 相关考题
考题 Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid line If excess moisture is present in the system, the indicator willA.activate the driersB.change colorC.secure the compressorD.add a predetermined amount of liquid drier

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid lineIf excess moisture is present in the system, the indicator will ()A activate the driersB change colorC secure the compressorD add a predetermined amount of liquid drier

考题 单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()A Proper refrigerant chargeB Faulty expansion valveC Insufficient refrigerantD Solenoid valve stuck open

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling

考题 单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A too much refrigerant in the systemB oil entrained in the refrigerantC less than a full charge of refrigerant in the systemD ice crystals forming in the refrigerant

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题Air entering an air-cooled refrigeration system is indicated by ().A frosting of the liquid lineB higher than normal head pressureC a clear sight glassD abnormally cold reefer boxes

考题 单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A increaseB reduceC maintain constantD None of the above is true

考题 单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A high pressure liquid lineB low pressure liquid lineC high pressure vapor lineD low pressure vapor line

考题 单选题A liquid sight flow indicator in a refrigeration system is examined and gas bubbles are noted in motion with the fluid flowThis means ().A the system is fully chargedB there is air leaking in from the condenserC ice crystals are forming in the refrigerantD the system contains less than a full charge of refrigerant

考题 单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()A The liquid receiver functions to collect and remove non-condensable gasesB A thermostatic expansion valve is used to control refrigerated space temperatureC Refrigerant temperature in an evaporator is directly related to refrigerant pressureD Dehydrators must be used continuously in a refrigeration system

考题 单选题In a compression refrigeration cycle, the temperature of the liquid refrigerant experiences its greatest decrease in the().A evaporatorB compressorC expansion valveD condenser

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题The accumulation of air and other non-condensable gases in a refrigeration system will ().A cause a loss of the liquid sealB create a vapor lock in the liquid receiverC collect in the condenserD cause foaming of the oil in the crankcase

考题 单选题Which of the listed statements is correct concerning refrigeration systems?()A Dehydrators must be used continuously in a refrigeration systemB A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursC A thermostatic expansion valve is used to control refrigerated space temperatureD The liquid receiver functions to collect and remove non- condensable gases

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题A purge recovery system is used in a centrifugal air conditioning or refrigeration system to ()A purge lube oil from the liquid refrigerantB recover water purged from the systemC separate foul gases from the receiverD purge non-condensable gases without losing refrigerant

考题 单选题The closed-loop system differs from the open-loop system by()A the lack of a feedbackB the presence of a feed backC the lack of a computerD the presence of a computer

考题 单选题The receiver used in a refrigeration system()A stores liquid refrigerantB collects non-condensable gasesC allows refrigerant sub-coolingD prevents compressor surging

考题 单选题A pressure drop in the liquid line of a refrigeration system may cause()A the solenoid valve to seizeB the compressor to huntC flash gas to form in the liquid lineD the expansion valve to freeze open