单选题
When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().
A

flooding back

B

superheating

C

overflowing

D

recycling


参考答案

参考解析
解析: 暂无解析
更多 “单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid lineIf excess moisture is present in the system, the indicator will ()A activate the driersB change colorC secure the compressorD add a predetermined amount of liquid drier

考题 单选题The device, which is installed in the compressor suction line to prevent liquid from entering the compressor when hot gas defrosting, is called a()A re-evaporatorB receiverC dehydratorD solenoid

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles

考题 单选题The unloading system on an air compressor will ().A increase compressor discharge pressure on demandB increase compressor operating speed as necessaryC allow the motor to turn the compressor opposed only by frictionD reduce the compressor frictional load when starting

考题 单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().A the compressor suction pressure is not too highB all air is purged from the pump and charging fittingsC the high pressure cutout switch is held open to prevent accidental startingD the condenser is completely shutdown first

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then close until the compressor restartsD always be completely closed until the compressor restarts

考题 单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A high pressure liquid lineB low pressure liquid lineC high pressure vapor lineD low pressure vapor line

考题 单选题Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()A Sub-cooled liquidB Sub-cooled vaporC Superheated vaporD Liquid

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题The accumulation of air and other non-condensable gases in a refrigeration system will ().A cause a loss of the liquid sealB create a vapor lock in the liquid receiverC collect in the condenserD cause foaming of the oil in the crankcase

考题 单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A liquidB dry saturated gasC wet saturated gasD superheated vapor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.A has continuously for a long periodB suction pressure is below normalC oil level is below normalD starts after a long idle period

考题 单选题The receiver used in a refrigeration system()A stores liquid refrigerantB collects non-condensable gasesC allows refrigerant sub-coolingD prevents compressor surging

考题 单选题A pressure drop in the liquid line of a refrigeration system may cause()A the solenoid valve to seizeB the compressor to huntC flash gas to form in the liquid lineD the expansion valve to freeze open