An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().
A
restriction in refrigerant piping
B
air and non-condensable gases in the condenser
C
water in the refrigerant
D
flooding back of liquid refrigerant from the evaporator
参考答案
参考解析
解析:
暂无解析
更多 “单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator” 相关考题
考题
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
考题
If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
考题
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A
pressurestatB
high pressure cutoutC
solenoid valveD
low pressure cutout switch
考题
单选题The refrigeration system low pressure cutout switch is actuated by ().A
an electric system managerB
a sensing bulb at the tail coil of the evaporatorC
pressure changes in the suction lineD
failure of the king solenoid valve
考题
单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A
increase the flow of the cooling water through the condenserB
adjust the high pressure cutout to maintain the desired pressureC
open the hot gas bypass temporarily to reduce capacityD
purge non-condensable gases to reduce the excess pressure
考题
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A
broken valve springsB
tight drive beltsC
high line voltageD
air in the system
考题
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A
purge the condenser if the waterside is dirtyB
check for proper water flow through the condenserC
increase the high pressure cutout settingD
reduce the cooling water flow
考题
单选题Air entering an air-cooled refrigeration system is indicated by ().A
frosting of the liquid lineB
higher than normal head pressureC
a clear sight glassD
abnormally cold reefer boxes
考题
单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A
increaseB
reduceC
maintain constantD
None of the above is true
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A
the compressor short cycling on high pressure cut out switchB
high suction pressureC
high head pressureD
bubbles in the sight glass
考题
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A
the relief valve should open before the high pressure cutoutB
the relief valve should open and allow the excess refrigerant to flow to the receiverC
the high pressure cutout switch should operate before the relief valve opensD
you should close in on the suction valve
考题
单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A
refrigerant boiling out of solution from the lube oilB
liquid refrigerant flooding the compressor and systemC
lube oil viscosity being reduced by refrigerant dilutionD
compressor suction pressure suddenly increasing
考题
单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A
high pressure liquid lineB
low pressure liquid lineC
high pressure vapor lineD
low pressure vapor line
考题
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A
Condenser and thermal expansion valveB
King and solenoid valvesC
Compressor and thermal expansion valveD
Condenser and solenoid valve
考题
单选题One cause of high head pressure occurring in a refrigeration system can be ().A
insufficient cooling water flow to the condenserB
a low refrigerant charge in the systemC
the liquid valve is open too muchD
high evaporator superheat
考题
单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().A
sub-cooled liquidB
high temperature liquidC
oil saturated liquidD
superheated vapor
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
单选题An increase in the heat load to a refrigeration system will cause ().A
the suction pressure to decreaseB
the suction temperature to increaseC
increased ice formation on the evaporator coilD
excessive short cycling of the compressor
考题
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A
in the chill boxB
before the receiverC
on the suction side of the compressorD
on the discharge side of the compressor
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some refrigerant from the system
考题
单选题The low pressure side of a refrigeration system is considered to exist from the ().A
expansion valve to the compressorB
receiver to the expansion coilC
expansion valve to the evaporatorD
condenser to the expansion valve