The refrigeration system low pressure cutout switch is actuated by ().
A

an electric system manager

B

a sensing bulb at the tail coil of the evaporator

C

pressure changes in the suction line

D

failure of the king solenoid valve


参考答案

参考解析
解析: 暂无解析
更多 “单选题The refrigeration system low pressure cutout switch is actuated by ().A an electric system managerB a sensing bulb at the tail coil of the evaporatorC pressure changes in the suction lineD failure of the king solenoid valve” 相关考题
考题 If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

考题 When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A pressurestatB high pressure cutoutC solenoid valveD low pressure cutout switch

考题 单选题The device used for low-pressure control and high-pressure cutout on a compressor is called a()A cutoutB pressure controllerC controller switchD cutout switch

考题 单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A increase the flow of the cooling water through the condenserB adjust the high pressure cutout to maintain the desired pressureC open the hot gas bypass temporarily to reduce capacityD purge non-condensable gases to reduce the excess pressure

考题 单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().A the compressor suction pressure is not too highB all air is purged from the pump and charging fittingsC the high pressure cutout switch is held open to prevent accidental startingD the condenser is completely shutdown first

考题 单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A purge the condenser if the waterside is dirtyB check for proper water flow through the condenserC increase the high pressure cutout settingD reduce the cooling water flow

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题If the compressor runs continually, the cause might be the()A high-pressure cutout switch is jammed openB low-pressure switch is jammed shutC thermal bulb is not operating properlyD scale trap is clogged

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().A sub-cooled liquidB high temperature liquidC oil saturated liquidD superheated vapor

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题Constant superheat is maintained at the evaporator outlet of a refrigeration coil by a()A solenoid valveB low pressure cutout switchC king valveD thermal expansion valve

考题 单选题The low pressure side of a refrigeration system is considered to exist from the ().A expansion valve to the compressorB receiver to the expansion coilC expansion valve to the evaporatorD condenser to the expansion valve

考题 单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A Thermal expansion valve frozen openB Suction gas heat exchanger bypassedC Condenser clogged or fouledD High pressure cutout switch inoperative