The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()
A

system is overcharged with refrigerant

B

system is low on refrigerant

C

discharge valves are leaking excessively

D

discharge valves are leaking slightly


参考答案

参考解析
解析: 暂无解析
更多 “单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly” 相关考题
考题 Moisture is removed from a refrigeration system byA.bleeding refrigerant from the condenserB.opening a drain petcock on the oil separatorC.condensing the water in the heat exchangerD.using a dehydrator cartridge

考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling

考题 单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A increase the flow of the cooling water through the condenserB adjust the high pressure cutout to maintain the desired pressureC open the hot gas bypass temporarily to reduce capacityD purge non-condensable gases to reduce the excess pressure

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().A overheated compressor bearingsB excess lube oil viscosityC carbon deposits on the compressor piston ringsD wax crystals forming in the lubricant

考题 单选题Short cycling of a refrigeration compressor refers to ().A frequently grounding outB frequently starting and stoppingC running too fastD running too slow

考题 单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A a shortage of compressor oilB warm food in the refrigeratorC excessive condenser cooling waterD a shortage of refrigerant

考题 单选题Air entering an air-cooled refrigeration system is indicated by ().A frosting of the liquid lineB higher than normal head pressureC a clear sight glassD abnormally cold reefer boxes

考题 单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A increaseB reduceC maintain constantD None of the above is true

考题 单选题()are supplied by main switchboard directly.A Suez Canal searchlight, air compressor and air conditioning compressorB Air compressor, boiler blower and refrigeration plantC Boiler blower, Suez Canal searchlight and refrigeration plantD Suez canal searchlight, air compressor and boiler blower

考题 单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then close until the compressor restartsD always be completely closed until the compressor restarts

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题If the capacity of the refrigeration compressor is too large, the saturation temperature will ().A riseB fallC be maintained constantD None of the above

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题In the refrigeration compressor the temperature of the vapor is () by compression.A raisedB risenC reducedD maintained constant

考题 单选题It should be ensured that only () vapor is handled by the refrigeration compressor.A humidityB dryC steamD oil

考题 单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA any of (1) and (3)B any of (1) and (2)C any of (2) and (3)D any of (1), (2) and (3)

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.A has continuously for a long periodB suction pressure is below normalC oil level is below normalD starts after a long idle period

考题 单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion