If the head pressure of a reciprocating refrigeration compressor is excessive, ().
A

the relief valve should open before the high pressure cutout

B

the relief valve should open and allow the excess refrigerant to flow to the receiver

C

the high pressure cutout switch should operate before the relief valve opens

D

you should close in on the suction valve


参考答案

参考解析
解析: 暂无解析
更多 “单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve” 相关考题
考题 If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

考题 If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A pressurestatB high pressure cutoutC solenoid valveD low pressure cutout switch

考题 单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A increase the flow of the cooling water through the condenserB adjust the high pressure cutout to maintain the desired pressureC open the hot gas bypass temporarily to reduce capacityD purge non-condensable gases to reduce the excess pressure

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题() provides the head or pressure to supply the domestic water where required.A The compressed airB The compressing airC The transfer pumpD The head tank

考题 单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A broken valve springsB tight drive beltsC high line voltageD air in the system

考题 单选题Which of the following statements represents the advantage of rotary pumps as compared to reciprocating pumps?()A The high discharge pressure of the rotary pumps permits a larger volume of fluid per unit time than the reciprocating pumpB Rotary pumps are capable of pumping more fluid than reciprocating pumps of the same weightC Rotary pumps occupy only one-half the space of reciprocating pumpsD Rotary pumps eliminate discharge slippage of the pumped liquid, while this does not hold true for a reciprocating pump

考题 单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A purge the condenser if the waterside is dirtyB check for proper water flow through the condenserC increase the high pressure cutout settingD reduce the cooling water flow

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A increaseB reduceC maintain constantD None of the above is true

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A the compressor short cycling on high pressure cut out switchB high suction pressureC high head pressureD bubbles in the sight glass

考题 单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().A high pressure liquid lineB low pressure liquid lineC high pressure vapor lineD low pressure vapor line

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题Constant superheat is maintained at the evaporator outlet of a refrigeration coil by a()A solenoid valveB low pressure cutout switchC king valveD thermal expansion valve

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题Bad valves operation of the reciprocating air compressors can be detected by observation of ().A the discharge temperature lowB the discharge temperature highC the discharge pressure riseD the inter-stage pressure low

考题 单选题The amount of fluid delivered by a reciprocating pump can be regulated by ().A throttling the pressure lineB changing the speed of the pistonC either A or BD None of the above is tree

考题 单选题The volute of centrifugal pump also acts as a diffuser converting ()into pressure head.A mechanical energyB heat energyC potential energyD kinetic head