One cause of high head pressure occurring in a refrigeration system can be ().
A

insufficient cooling water flow to the condenser

B

a low refrigerant charge in the system

C

the liquid valve is open too much

D

high evaporator superheat


参考答案

参考解析
解析: 暂无解析
更多 “单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

考题 If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题Which of the following problems represent one possible cause of high lube oil consumption in a four stroke diesel engine?()A Worn intake valve guidesB Pitted pre-combustion chambersC Loose valve tappetsD High exhaust back pressure

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A purge the condenser if the waterside is dirtyB check for proper water flow through the condenserC increase the high pressure cutout settingD reduce the cooling water flow

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A A shortage of liquid refrigerantB Excessive frost on the evaporatorC Excessive condenser cooling waterD Insufficient condenser cooling water flow

考题 单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().A run continuouslyB not startC have high discharge pressureD short cycle on the high pressure switch

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A the compressor short cycling on high pressure cut out switchB high suction pressureC high head pressureD bubbles in the sight glass

考题 单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题Which cause of following will not lead to refrigeration plant short-cycle?()A lack of refrigerantB refrigerant with much waterC set defectively low pressure relayD no cooling water

考题 单选题If the head pressure is too high,()A the relief valve should open before the high-pressure cutoutB the relief valve should open and let excess refrigerant go to receiverC the high-pressure cutout switch should operate before the relief valve opensD close in on the suction valve

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题In a compression refrigeration plant the hot, high pressure refrigerant gas is cooled by the sea water and becomes liquid in the ().A compressorB condenserC throttle valveD evaporator

考题 单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA any of (1) and (3)B any of (1) and (2)C any of (2) and (3)D any of (1), (2) and (3)

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题In a refrigeration system, which of the following statements describes the actions occurring when a solenoid valves, used in conjunction with an unloader head is energized?()A The solenoid valves directs high pressure gas to the valve lifting device raising the suction valve off its seat and causing one specific cylinder to become unloadedB The solenoid valves directs high pressure gas to the underside of the unloading piston, causing it to rise and allowing the recirculating ports to be openedC When the solenoid valve becomes energized, the valve ports become closed, allowing discharge pressure to build up above the piston, shifting it and causing it to unloadD The solenoid valve allows the refrigerant to pass from the suction chamber to the top of the unloader piston, causing the piston to lift and unload the cylinder

考题 单选题If a compressor runs continuously, the cause might be a()A defective thermal bulbB clogged scale trapC stuck high-pressure switchD stuck low-pressure switch