单选题
If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().
A

run continuously

B

not start

C

have high discharge pressure

D

short cycle on the high pressure switch


参考答案

参考解析
解析: 暂无解析
更多 “单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().A run continuouslyB not startC have high discharge pressureD short cycle on the high pressure switch” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 Badly leaking refrigeration compressor discharge valves will cause ______.A.overfeeding of the expansion valveB.damage to the condenserC.constant running of the compressorD.flooding of the receiver

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 单选题If a large difference exists between the compressor discharge pressure and the pressure corresponding to the existing condensing temperature in a refrigeration system, you should().A increase the flow of the cooling water through the condenserB adjust the high pressure cutout to maintain the desired pressureC open the hot gas bypass temporarily to reduce capacityD purge non-condensable gases to reduce the excess pressure

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().A overheated compressor bearingsB excess lube oil viscosityC carbon deposits on the compressor piston ringsD wax crystals forming in the lubricant

考题 单选题The unloading system on an air compressor will ().A increase compressor discharge pressure on demandB increase compressor operating speed as necessaryC allow the motor to turn the compressor opposed only by frictionD reduce the compressor frictional load when starting

考题 单选题Insufficient refrigerant in a refrigeration plant may result in ().A high discharge pressureB frosting of the crankcaseC high temperature of the overboard waterD low suction pressure of compressor

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题Badly leaking refrigeration compressor discharge valves will cause().A overfeeding of the expansion valveB damage to the condenserC constant running of the compressorD flooding of the receiver

考题 单选题()are supplied by main switchboard directly.A Suez Canal searchlight, air compressor and air conditioning compressorB Air compressor, boiler blower and refrigeration plantC Boiler blower, Suez Canal searchlight and refrigeration plantD Suez canal searchlight, air compressor and boiler blower

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题In the refrigeration compressor the temperature of the vapor is () by compression.A raisedB risenC reducedD maintained constant

考题 单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA any of (1) and (3)B any of (1) and (2)C any of (2) and (3)D any of (1), (2) and (3)

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题Excessively low air pressure occurring in the intercooler of a reciprocating air compressor is caused by().A leaky discharge valves on the LP cylinderB leaky discharge valves on the HP cylinderC insufficient intercooler coolingD low ambient air pressure

考题 单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A Thermal expansion valve frozen openB Suction gas heat exchanger bypassedC Condenser clogged or fouledD High pressure cutout switch inoperative