Badly leaking refrigeration compressor discharge valves will cause ______.

A.overfeeding of the expansion valve

B.damage to the condenser

C.constant running of the compressor

D.flooding of the receiver


参考答案

更多 “ Badly leaking refrigeration compressor discharge valves will cause ______.A.overfeeding of the expansion valveB.damage to the condenserC.constant running of the compressorD.flooding of the receiver ” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems

考题 What is the most probable cause of reduced capacity in a reciprocating air compressor ________.A.Carbon on cylinder headsB.Faulty unloaderC.Leaking air valvesD.Plugged air cooler

考题 单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A Closing of the solenoid valveB Closing of the expansion valveC An increase in the suction pressureD Decreasing the suction pressure

考题 单选题Insufficient refrigerant in a refrigeration plant may result in ().A high discharge pressureB frosting of the crankcaseC high temperature of the overboard waterD low suction pressure of compressor

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题Badly leaking refrigeration compressor discharge valves will cause().A overfeeding of the expansion valveB damage to the condenserC constant running of the compressorD flooding of the receiver

考题 单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().A run continuouslyB not startC have high discharge pressureD short cycle on the high pressure switch

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题If a refrigeration compressor will not start, the reason may be ().A the pressure regulating valve is not closingB an excessive lack of refrigerant in the systemC badly leaking discharge valvesD worn piston rings

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA any of (1) and (3)B any of (1) and (2)C any of (2) and (3)D any of (1), (2) and (3)

考题 单选题The purpose of the refrigeration system low pressure cutout switch is to ()A protect the compressor from liquid flood backB protect the compressor from low discharge pressureC start and stop the compressor upon system demandD start the compressor after a drop in the evaporator pressure

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题Excessively low air pressure occurring in the intercooler of a reciprocating air compressor is caused by().A leaky discharge valves on the LP cylinderB leaky discharge valves on the HP cylinderC insufficient intercooler coolingD low ambient air pressure

考题 单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A Thermal expansion valve frozen openB Suction gas heat exchanger bypassedC Condenser clogged or fouledD High pressure cutout switch inoperative