Insufficient refrigerant in a refrigeration plant may result in ().
A

high discharge pressure

B

frosting of the crankcase

C

high temperature of the overboard water

D

low suction pressure of compressor


参考答案

参考解析
解析: 暂无解析
更多 “单选题Insufficient refrigerant in a refrigeration plant may result in ().A high discharge pressureB frosting of the crankcaseC high temperature of the overboard waterD low suction pressure of compressor” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 Sludge may be formed in the oil in the crankcase of a reciprocating air conditioning compressor as a result of ______.A.refrigerant bubbles in the lube oilB.refrigerant reducing the lube oil viscosityC.oxidation(氧化) of the lube oil from overheatingD.reducing the floc or cloud point of the oil

考题 A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题Excessive scale formation in a distilling plant may result from ().A poor distillate qualityB reduced evaporator capacityC low brine concentrationD improper vacuum regulation

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A compressorB condenserC receiverD evaporator

考题 单选题The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()A latent heat of expansionB sensible heat of condensationC heat of compressionD all of the above

考题 单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.A compressorB condenserC throttle valveD evaporator

考题 单选题Air that may enter a refrigeration plant tends to collect in the ().A upper part of the receiverB upper part of the condenserC down stream end of the cooling coilD outlet end of the condenser

考题 单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.A filterB filter drierC heat exchangerD air cooler

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题If a refrigeration compressor will not start, the reason may be ().A the pressure regulating valve is not closingB an excessive lack of refrigerant in the systemC badly leaking discharge valvesD worn piston rings

考题 单选题Before charging a refrigeration unit, the refrigerant charging lines should be()A flushed with clean refrigerant oilB purged with the refrigerantC washed with an ammonia and alcohol solutionD grounded to compressor

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题Refrigerant is circulated through a refrigeration system by the ().A compressorB condenserC expansion valveD evaporator

考题 单选题Saltwater is typically provided to a refrigeration system to ().A cool the expansion valveB prevent refrigerant superheatingC condense the refrigerant gasD prevent motor overheating

考题 单选题In a compression refrigeration plant the hot, high pressure refrigerant gas is cooled by the sea water and becomes liquid in the ().A compressorB condenserC throttle valveD evaporator

考题 单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA any of (1) and (3)B any of (1) and (2)C any of (2) and (3)D any of (1), (2) and (3)

考题 单选题In a refrigeration plant the () need defrosting.A fanB compressorC condenserD evaporator

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion