网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The compressor suction line conveys the refrigerant vapor from () to ().
A

condenser;evaporator

B

evaporator;compressor

C

compressor;condenser

D

None of the above


参考答案

参考解析
解析: 暂无解析
更多 “单选题The compressor suction line conveys the refrigerant vapor from () to ().A condenser;evaporatorB evaporator;compressorC compressor;condenserD None of the above” 相关考题
考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

考题 If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

考题 If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 In a chilled(冷的) water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ______.A.increasing refrigerant pressure in the coilB.increasing chilled water flow through the coolerC.sub-cooling the refrigerant in the condenserD.superheating the refrigerant in the compressor

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line

考题 单选题The device, which is installed in the compressor suction line to prevent liquid from entering the compressor when hot gas defrosting, is called a()A re-evaporatorB receiverC dehydratorD solenoid

考题 单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling

考题 单选题Insufficient refrigerant in a refrigeration plant may result in ().A high discharge pressureB frosting of the crankcaseC high temperature of the overboard waterD low suction pressure of compressor

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().A liquid strainerB refrigerant inlet of the condenserC inlet side of the evaporatorD suction side of the compressor

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题A warmer than normal compressor suction line might be caused by ().A insufficient lubricationB insufficient refrigerantC excess refrigerantD excessive opening of the expansion valve

考题 单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A the relief valve should open before the high pressure cutoutB the relief valve should open and allow the excess refrigerant to flow to the receiverC the high pressure cutout switch should operate before the relief valve opensD you should close in on the suction valve

考题 单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A refrigerant boiling out of solution from the lube oilB liquid refrigerant flooding the compressor and systemC lube oil viscosity being reduced by refrigerant dilutionD compressor suction pressure suddenly increasing

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ().A increasing refrigerant pressure in the coilB increasing chilled water flow through the coolerC sub-cooling the refrigerant in the condenserD superheating the refrigerant in the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A liquidB dry saturated gasC wet saturated gasD superheated vapor

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题“Flooding back” is a condition where the liquid refrigerant ().A vaporizes in the condenserB reaches the compressor through the suction lineC flashes in the liquid lineD condenses in the receiver

考题 单选题The purpose of the low pressure cut-out switch is to ().A maintain liquid refrigerant at the suction of the compressorB maintain a preset suction pressure to the compressorC start and stop the compressor at preset operating pressuresD operate at minimum efficiency

考题 单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().A condition of the expansion valveB moisture in the systemC condition of the compressor suction valvesD condenser temperature

考题 单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().A carbon deposits on the compressor suction valvesB the evaporator temperature to increaseC rapid corrosion of the thermal expansion valveD no operating problems