“Flooding back” is a condition where the liquid refrigerant ().
A

vaporizes in the condenser

B

reaches the compressor through the suction line

C

flashes in the liquid line

D

condenses in the receiver


参考答案

参考解析
解析: 暂无解析
更多 “单选题“Flooding back” is a condition where the liquid refrigerant ().A vaporizes in the condenserB reaches the compressor through the suction lineC flashes in the liquid lineD condenses in the receiver” 相关考题
考题 To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the_______ .A.suction service valve as a vaporB.suction service valve as a liquidC.discharge service valve as a vaporD.charging valve as a liquid

考题 If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

考题 单选题A positive displacement pump is that where the volume of the pump chamber is alternately increased to () and then decreased to ().A draw the liquid in;force the liquid outB force the liquid out;draw the liquid inC suction;drawD deliver;outlet

考题 单选题Which of the problems listed could be indicated if a sight glass in the refrigerant liquid line is full of bubbles?()A Proper refrigerant chargeB Faulty expansion valveC Insufficient refrigerantD Solenoid valve stuck open

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A too much refrigerant in the systemB oil entrained in the refrigerantC less than a full charge of refrigerant in the systemD ice crystals forming in the refrigerant

考题 单选题A pressure drop through the refrigerant liquid line may cause ().A solenoid valve to seizeB compressor to huntC formation of flash gas in the liquid lineD expansion valve to freeze open

考题 单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A refrigerant boiling out of solution from the lube oilB liquid refrigerant flooding the compressor and systemC lube oil viscosity being reduced by refrigerant dilutionD compressor suction pressure suddenly increasing

考题 多选题Which three are true regarding the use of outer joins? ()AYou cannot use IN operator in a condition that involves an outerjoin.BYou use (+) on both sides of the WHERE condition to perform an outerjoin.CYou use (*) on both sides of the WHERE condition to perform an outerjoin.DYou use an outerjoin to see only the rows that do not meet the join condition.EIn the WHERE condition, you use (+) following the name of the column in the table without matching rows, to perform an outerjoin.FYou cannot link a condition that is involved in an outerjoin to another condition by using the OR operator.

考题 单选题In a compression refrigeration cycle, the temperature of the liquid refrigerant experiences its greatest decrease in the().A evaporatorB compressorC expansion valveD condenser

考题 单选题Moisture in the refrigerant may ().A freeze on the expansion valve seat and reduce the flow of liquid refrigerantB emulsify the oil in the condenserC freeze in the king valveD clog the oil trap

考题 单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()A suction service valve as a vaporB suction service valve as a liquidC discharge service valve as a vaporD charging valve as a liquid

考题 单选题Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()A At the designed operating temperature, the liquid refrigerant charge has changed to a vaporB The liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivityC The sensing bulb is empty of liquid refrigerant charge at the designed operating temperatureD The sensing bulb is never emptied of liquid refrigerant under normal operating conditions

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题The principal purpose of sub-cooling liquid refrigerant prior to its entering the expansion valve is to ().A increase the refrigerating effect, by decreasing the amount of flash gasB allow the refrigerant to enter the throttling device in a saturated conditionC increase the refrigerating effect by increasing the amount of flash gasD minimize the temperature drop of the liquid as it passes through the solenoid valve to the outlet side

考题 单选题Sub-cooling is a method of reducing the temperature of the liquid refrigerant below its ().A freezing pointB floc pointC condensing temperatureD compression temperature

考题 单选题Of a kind of liquid is used to cool the diesel engine, it is invariably called ()A lubricantB coolantC combustion productD second refrigerant

考题 单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().A re-adjust the discharge pressureB clean the expansion valve screenC add refrigerantD adjust the expansion valve

考题 单选题If liquid refrigerant accidentally comes in contact with the eyes, () immediately.A rub the eyesB irritate the eyesC wash the eyes with a heavy boric acid solutionD obtain medical help

考题 单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().A condition of the expansion valveB moisture in the systemC condition of the compressor suction valvesD condenser temperature