网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
A warmer than normal compressor suction line might be caused by ().
A
insufficient lubrication
B
insufficient refrigerant
C
excess refrigerant
D
excessive opening of the expansion valve
参考答案
参考解析
解析:
暂无解析
更多 “单选题A warmer than normal compressor suction line might be caused by ().A insufficient lubricationB insufficient refrigerantC excess refrigerantD excessive opening of the expansion valve” 相关考题
考题
If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress
考题
Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor
考题
The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor
考题
If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling
考题
An increase in the heat load to a refrigeration system will cause ______.A.the suction pressure to decreaseB.the suction temperature to increaseC.increased ice formation on the evaporator coilD.excessive short cycling of the compressor
考题
Which of the problems listed could cause erosion of the expansion valve disks and seats?A.Overcharging the system with refrigerantB.Faulty compressor suction valveC.Failure of the high pressure cutoutD.Flash gas formed in the liquid line
考题
单选题Excessive lube oil consumption by a reciprocating air compressor can be caused by ().A
using a slightly dirty air filterB
using oil having an excessive viscosityC
intercooler or after-cooler leaksD
carrying the oil level higher than normal
考题
单选题The device, which is installed in the compressor suction line to prevent liquid from entering the compressor when hot gas defrosting, is called a()A
re-evaporatorB
receiverC
dehydratorD
solenoid
考题
单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A
flooding backB
superheatingC
overflowingD
recycling
考题
单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A
Closing of the solenoid valveB
Closing of the expansion valveC
An increase in the suction pressureD
Decreasing the suction pressure
考题
单选题Which statement is TRUE about nylon line?()A
Manila line will usually last longer than nylon lineB
Nylon line is excellent for use in alongside towingC
A normal safe working load will stretch nylon line 50%D
Nylon stoppers should be used with nylon line
考题
单选题Higher than normal jacket water temperatures occurring in all cylinders of a diesel engine can result from a/an ().A
oil suction line restrictionB
correct amount of coolantC
cavitation erosion in the water jacketsD
clogged sea suction strainer
考题
单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A
refrigerant boiling out of solution from the lube oilB
liquid refrigerant flooding the compressor and systemC
lube oil viscosity being reduced by refrigerant dilutionD
compressor suction pressure suddenly increasing
考题
单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A
refrigerant overchargeB
overfeeding by the expansion valveC
a restricted suction strainerD
due to short cycling of the compressor
考题
单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A
oil foaming in the compressorB
higher than normal suction and discharge pressures with a higher box temperatureC
higher than normal discharge pressure with a normal box temperatureD
the compressor to run continuously
考题
单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A
compressor damage from improper lubricationB
refrigerant absorption by the lubricantC
increased viscosity in the lubricantD
carbon deposit on the compressor suction valves
考题
单选题A dirty intercooler on the ship service air compressor will result in ().A
decreased compression ratioB
higher than normal power consumptionC
un-loader malfunctionD
water in the lubricating oil
考题
单选题The static suction head of is the ()A
distance of the suction liquid level above the line of the pumpB
distance the suction liquid level is below the center line of the pumpC
force necessary to overcome frictional losses in the pump and pipingD
amount in inches of mercury the total suction head is below atmospheric pressure
考题
单选题Most pump manufacturers recommend that the suction piping dimension for centrifugal pumps be ().A
one size smaller than the pump suction nozzleB
the same size as the pump suction nozzleC
one size larger than the pump suction nozzleD
installed with a short radius elbow at the pump
考题
单选题An increase in the heat load to a refrigeration system will cause ().A
the suction pressure to decreaseB
the suction temperature to increaseC
increased ice formation on the evaporator coilD
excessive short cycling of the compressor
考题
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A
in the chill boxB
before the receiverC
on the suction side of the compressorD
on the discharge side of the compressor
考题
单选题The compressor suction line conveys the refrigerant vapor from () to ().A
condenser;evaporatorB
evaporator;compressorC
compressor;condenserD
None of the above
考题
单选题Sweating of the refrigeration system compressor crankcase is caused by ().A
too much superheatB
insufficient superheatC
suction pressure too lowD
excessive refrigerant returning to the compressor
考题
单选题The major difference between the discharge and suction valves installed in most low pressure, reciprocating air compressors is that()A
one valve seats upwards, while the other seats downwardsB
the reed valves used on the discharge are made substantially thicker and heavier than the suction valvesC
the suction valve springs exert a greater tension than the discharge valve springsD
the discharge valve springs exert a greater tension than the suction valve springs
考题
单选题The purpose of the low pressure cut-out switch is to ().A
maintain liquid refrigerant at the suction of the compressorB
maintain a preset suction pressure to the compressorC
start and stop the compressor at preset operating pressuresD
operate at minimum efficiency
考题
单选题A bilge suction line,in a fishing vessel with more than 16 individuals aboard,must have a strainer with an open area not less than how many times the open area of the suction line?()A
oneB
twoC
threeD
four
考题
单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().A
condition of the expansion valveB
moisture in the systemC
condition of the compressor suction valvesD
condenser temperature