An increase in the heat load to a refrigeration system will cause ______.

A.the suction pressure to decrease

B.the suction temperature to increase

C.increased ice formation on the evaporator coil

D.excessive short cycling of the compressor


参考答案

更多 “ An increase in the heat load to a refrigeration system will cause ______.A.the suction pressure to decreaseB.the suction temperature to increaseC.increased ice formation on the evaporator coilD.excessive short cycling of the compressor ” 相关考题
考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems

考题 The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

考题 WHEN CONTACT MADE WITH THE RADIO STATION OAS AT SAN JUAN,A PRE-STOWAGE HATCH LIST WITH SEQUENCE OF LOADING TO BE SENT TO LOAD PORT NOT LESS THAN 48 HRS IN ADVANCE.From this fax,the pre-stowage hatch list shall be sent to ______.A.THE RADIO STATIONB.SAN JUANC.OASD.LOAD PORT

考题 单选题The refrigeration system low pressure cutout switch is actuated by ().A an electric system managerB a sensing bulb at the tail coil of the evaporatorC pressure changes in the suction lineD failure of the king solenoid valve

考题 单选题The latent heat of evaporation is dissipated in the () in a compression refrigeration system.A evaporatorB condenserC expansion valveD compressor

考题 单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A flooding backB superheatingC overflowingD recycling

考题 单选题What is the purpose of sub cooling R-12 in the condenser?()A to increase the system efficiency by sensible heat transferB to stop the liquid from flashingC to reduce the load on the compressorD to remove latent heat of vaporization and the suction piping transfer

考题 单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A compressorB condenserC receiverD evaporator

考题 单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A Closing of the solenoid valveB Closing of the expansion valveC An increase in the suction pressureD Decreasing the suction pressure

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题Which of the following terms represents the form of heat removed from the refrigerant in the condenser of a refrigeration system?()A Latent heat of vaporizationB Heat of compressionC SuperheatD All of the above

考题 单选题Moisture is removed from a refrigeration system by().A bleeding refrigerant from the condenserB opening a drain petcock on the oil separatorC condensing the water in the heat exchangerD using a dehydrator cartridge

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题What will NOT increase friction of a liquid flowing in a pipe and cause a loss of suction head?().A Bends in the pipingB Slowing the pumping rateC Pipeline valvesD Backing rings for pipe welds

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题Moisture in a refrigeration system can cause ().A freezing the expansion valve closedB corrosion of system pipingC improper temperature regulationD all of the above

考题 单选题When the heat load begins to increase, the needle valve of an expansion valve will()A move in an opening directionB move in a closing directionC either open or closeD not move at all

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A in the chill boxB before the receiverC on the suction side of the compressorD on the discharge side of the compressor

考题 单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().A carbon deposits on the compressor suction valvesB the evaporator temperature to increaseC rapid corrosion of the thermal expansion valveD no operating problems