An increase in the heat load to a refrigeration system will cause ______.
A.the suction pressure to decrease
B.the suction temperature to increase
C.increased ice formation on the evaporator coil
D.excessive short cycling of the compressor
参考答案
更多 “ An increase in the heat load to a refrigeration system will cause ______.A.the suction pressure to decreaseB.the suction temperature to increaseC.increased ice formation on the evaporator coilD.excessive short cycling of the compressor ” 相关考题
考题
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
考题
If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress
考题
Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor
考题
The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor
考题
If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling
考题
Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems
考题
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
考题
WHEN CONTACT MADE WITH THE RADIO STATION OAS AT SAN JUAN,A PRE-STOWAGE HATCH LIST WITH SEQUENCE OF LOADING TO BE SENT TO LOAD PORT NOT LESS THAN 48 HRS IN ADVANCE.From this fax,the pre-stowage hatch list shall be sent to ______.A.THE RADIO STATIONB.SAN JUANC.OASD.LOAD PORT
考题
单选题The refrigeration system low pressure cutout switch is actuated by ().A
an electric system managerB
a sensing bulb at the tail coil of the evaporatorC
pressure changes in the suction lineD
failure of the king solenoid valve
考题
单选题The latent heat of evaporation is dissipated in the () in a compression refrigeration system.A
evaporatorB
condenserC
expansion valveD
compressor
考题
单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A
flooding backB
superheatingC
overflowingD
recycling
考题
单选题What is the purpose of sub cooling R-12 in the condenser?()A
to increase the system efficiency by sensible heat transferB
to stop the liquid from flashingC
to reduce the load on the compressorD
to remove latent heat of vaporization and the suction piping transfer
考题
单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A
compressorB
condenserC
receiverD
evaporator
考题
单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()A
Closing of the solenoid valveB
Closing of the expansion valveC
An increase in the suction pressureD
Decreasing the suction pressure
考题
单选题If a refrigeration system were short of refrigerant, the condition would result in ().A
continuous running of the compressorB
high suction pressureC
high discharge pressureD
short cycling of the compressor on the water failure switch
考题
单选题Which of the following terms represents the form of heat removed from the refrigerant in the condenser of a refrigeration system?()A
Latent heat of vaporizationB
Heat of compressionC
SuperheatD
All of the above
考题
单选题Moisture is removed from a refrigeration system by().A
bleeding refrigerant from the condenserB
opening a drain petcock on the oil separatorC
condensing the water in the heat exchangerD
using a dehydrator cartridge
考题
单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A
passing it through the expansion valveB
condensing refrigerant in the system condenserC
passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD
maintaining a high pressure on the systems receiver
考题
单选题What will NOT increase friction of a liquid flowing in a pipe and cause a loss of suction head?().A
Bends in the pipingB
Slowing the pumping rateC
Pipeline valvesD
Backing rings for pipe welds
考题
单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A
refrigerant overchargeB
overfeeding by the expansion valveC
a restricted suction strainerD
due to short cycling of the compressor
考题
单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A
oil foaming in the compressorB
higher than normal suction and discharge pressures with a higher box temperatureC
higher than normal discharge pressure with a normal box temperatureD
the compressor to run continuously
考题
单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A
compressor damage from improper lubricationB
refrigerant absorption by the lubricantC
increased viscosity in the lubricantD
carbon deposit on the compressor suction valves
考题
单选题Moisture in a refrigeration system can cause ().A
freezing the expansion valve closedB
corrosion of system pipingC
improper temperature regulationD
all of the above
考题
单选题When the heat load begins to increase, the needle valve of an expansion valve will()A
move in an opening directionB
move in a closing directionC
either open or closeD
not move at all
考题
单选题An increase in the heat load to a refrigeration system will cause ().A
the suction pressure to decreaseB
the suction temperature to increaseC
increased ice formation on the evaporator coilD
excessive short cycling of the compressor
考题
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A
in the chill boxB
before the receiverC
on the suction side of the compressorD
on the discharge side of the compressor
考题
单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().A
carbon deposits on the compressor suction valvesB
the evaporator temperature to increaseC
rapid corrosion of the thermal expansion valveD
no operating problems