单选题
Moisture in a refrigeration system can cause ().
A
freezing the expansion valve closed
B
corrosion of system piping
C
improper temperature regulation
D
all of the above
参考答案
参考解析
解析:
暂无解析
更多 “单选题Moisture in a refrigeration system can cause ().A freezing the expansion valve closedB corrosion of system pipingC improper temperature regulationD all of the above” 相关考题
考题
Ventilation ().A、is a system for moving fresh airB、can cut indoor pollution to a safe levelC、can cause some diseasesD、is better done through air-conditioning
考题
Moisture is removed from a refrigeration system byA.bleeding refrigerant from the condenserB.opening a drain petcock on the oil separatorC.condensing the water in the heat exchangerD.using a dehydrator cartridge
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid line If excess moisture is present in the system, the indicator willA.activate the driersB.change colorC.secure the compressorD.add a predetermined amount of liquid drier
考题
If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress
考题
An increase in the heat load to a refrigeration system will cause ______.A.the suction pressure to decreaseB.the suction temperature to increaseC.increased ice formation on the evaporator coilD.excessive short cycling of the compressor
考题
Restrictions occurring in the small orifices(孔) of pneumatic control system components can be caused by ______.A.moisture in the compressed air supplyB.excessive dryness in the compressed air supplyC.pressure surging in the compressed air receiverD.insufficient lubrication of the system components
考题
Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems
考题
A server is having problems booting into the operating system. Which of the following can provide important information to begin to troubleshoot the cause?()A、System logsB、Firmware updatesC、POST messagesD、Application logs
考题
A server is having problems booting into the operating system. Which of the following can provide important information to begin to trouble shoot the cause?()A、 System logsB、 Firmware updatesC、 POST messagesD、 Application logs
考题
单选题Dirt in a fuel oil system of a diesel engine can cause ()A
damage to strainersB
over-speeding of the engineC
excessive cooling of the engineD
injector damage
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题A refrigeration system contaminated with moisture can be affected by ().A
acid formationB
sludge formationC
ice in the expansion valveD
All of the above
考题
单选题Some refrigeration systems have chemical moisture indicators installed in conjunction with the sight glass in the liquid lineIf excess moisture is present in the system, the indicator will ()A
activate the driersB
change colorC
secure the compressorD
add a predetermined amount of liquid drier
考题
单选题Moisture should be kept out of an R-12 system because it tends to cause ().A
icing of the automatic controlsB
embrittlement of some parts of the automatic controlsC
sludge in the lubricating oilD
all of the above
考题
单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.A
filterB
filter drierC
heat exchangerD
air cooler
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题Moisture is removed from a refrigeration system by().A
bleeding refrigerant from the condenserB
opening a drain petcock on the oil separatorC
condensing the water in the heat exchangerD
using a dehydrator cartridge
考题
单选题In a refrigeration system, foaming of the crankcase oil may cause the ().A
expansion valve to overfeedB
compressor to knockC
water regulating valve to failD
crankcase drains to plug
考题
单选题A server is having problems booting into the operating system. Which of the following can provide important information to begin to trouble shoot the cause?()A
System logsB
Firmware updatesC
POST messagesD
Application logs
考题
单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A
refrigerant overchargeB
overfeeding by the expansion valveC
a restricted suction strainerD
due to short cycling of the compressor
考题
单选题Dirt in the fuel oil system of a diesel engine can cause ().A
clogged filtersB
poor combustionC
overloading of the dieselD
shock of fuel lines
考题
单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A
oil foaming in the compressorB
higher than normal suction and discharge pressures with a higher box temperatureC
higher than normal discharge pressure with a normal box temperatureD
the compressor to run continuously
考题
单选题One cause of high head pressure occurring in a refrigeration system can be ().A
insufficient cooling water flow to the condenserB
a low refrigerant charge in the systemC
the liquid valve is open too muchD
high evaporator superheat
考题
单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A
compressor damage from improper lubricationB
refrigerant absorption by the lubricantC
increased viscosity in the lubricantD
carbon deposit on the compressor suction valves
考题
单选题An increase in the heat load to a refrigeration system will cause ().A
the suction pressure to decreaseB
the suction temperature to increaseC
increased ice formation on the evaporator coilD
excessive short cycling of the compressor
考题
单选题Adequate attention must be given to the water cooling system of the air compressors, for () can cause condensation on the cylinder walls.A
overcoolingB
poor coolingC
overloadingD
unloading