网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The brickwork surrounding the firebox of a boiler is known as().
A

refractory

B

the screen wall

C

the water wall

D

fire plate


参考答案

参考解析
解析: 暂无解析
更多 “单选题The brickwork surrounding the firebox of a boiler is known as().A refractoryB the screen wallC the water wallD fire plate” 相关考题
考题 The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure

考题 The water level in the gauge glass when a boiler is operating is _____ when the boiler is shut down.A.lower thanB.higher thanC.belowD.equal to

考题 How to operate boiler?

考题 what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .

考题 If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

考题 The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness

考题 A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

考题 Which statement about the inert gas system is TRUE ________.A.Boiler soot blowers should never be used when the IG system is operatingB.The boiler will produce the best quality of flue gas for the IG system when the boiler load is very lightC.The boiler will produce the most quantity of flue gas for the IG system when the boiler load is very lightD.Flue gas with excessive oxygen content is de-oxygenated in the scrubber

考题 The brickwork surrounding the firebox of a boiler is known as ______.A.RefractoryB.The screen wallC.The water wallD.Fire plate

考题 单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC the water tube boiler will cost shorter time for steam raisingD the water tube boiler require lower skill in operating and maintaining

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A operating the boiler at less than normal water levelB installing fins on the firesides of water-tubesC increasing the amount of excess air to the burnersD treating the boiler water with chemical oxygen scavengers

考题 单选题The correct procedure for giving an auxiliary boiler a bottom blow, is to begin()A when the boiler has been secured long enough for most solids to settleB when the boiler has been cooled to ambient temperatureC only after raising the water level to within 0~5 inch of the high water cutout onlyD after bypassing the low pressure

考题 单选题When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().A swellB shrinkageC flash offD lack of water

考题 单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A salinity is abnormally highB steam demand is too highC water level is abnormally lowD feedwater flow is low

考题 单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished

考题 单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A excessive purging before lighting offB insufficient trail for ignition periodC a faulty transformer in the ignition circuitD insufficient purging before lighting off

考题 单选题The moisture equilibrium chart can be used to determine the().A Absolute moisture content of the air surrounding a hygroscopic cargo when moisture equilibrium existsB Dew point temperature that the air surrounding a hygroscopic commodity will have when in moisture equilibrium with that commodityC Enthalpy of the air surrounding a hydroscopic cargo which is in moisture equilibrium with the cargoD Temperature at which moisture equilibrium will occur in a cargo hold containing a hygroscopic cargo

考题 单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A monkeyB donkeyC waste heatD main

考题 单选题A stream of water immediately surrounding a moving vessel’s hull,flowing in the same direction as the vessel is known as().A directional currentB forward currentC propeller currentD wake current

考题 单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()A precipitate silica from solutionB reduce corrosion in the heating coilC prevent clogging and erosion in the coilD maintain zero water hardness

考题 单选题() should be tested and adjusted when the boiler survey is carried out.A The boiler oil tankB The steam pipeC The fire sideD The safety valves

考题 单选题Foaming in the steam drum may be caused by () in a boiler.A oxygen in the waterB poor boiler designC density too highD excessive steam demand

考题 单选题When steam is being raised on a boiler, the water level will normally ().A drop as the boiler warms upB rise as the boiler warms upC remain unchanged until the boiler is hot enoughD rise and fall with the steam demand

考题 单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().A caustic embrittlement of the boiler metalB acidic corrosion of the boiler metalC hard scale deposits on the boiler tubesD etching of the heat exchange surfaces

考题 单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A high steam pressure in the boilerB abnormally high feed water temperatureC abnormally high boiler water temperatureD steam demand exceeding feed pump capacity

考题 单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A 10B 7C 4D 1