网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().
A

swell

B

shrinkage

C

flash off

D

lack of water


参考答案

参考解析
解析: 暂无解析
更多 “单选题When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().A swellB shrinkageC flash offD lack of water” 相关考题
考题 The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure

考题 The water level showing in a boiler water gauge glass is usually ( ) duringworking.A.higher than the actual drum water levelB.equal to the actual drum water levelC.increasing due to steam condensation in the glassD.lower than actual drum wafer level

考题 When using a fuel with a higher than normal sulfur content in an auxiliary four stroke diesel engine, you mayA.maintain higher than normal jacket water temperatureB.change the lube oil more frequently than normalC.maintain a higher air-box temperature than normalD.maintain a higher air-box pressure than normal

考题 Which statement about the inert gas system is TRUE ________.A.Boiler soot blowers should never be used when the IG system is operatingB.The boiler will produce the best quality of flue gas for the IG system when the boiler load is very lightC.The boiler will produce the most quantity of flue gas for the IG system when the boiler load is very lightD.Flue gas with excessive oxygen content is de-oxygenated in the scrubber

考题 单选题Overheating of a hydraulic system may be a result of ().A changing pump discharge pressure in response to normal load variationsB a high oil levelC incorrect fluid viscosityD continued slow re-circulation of the oil

考题 单选题To avoid excessive surge pressure when bunkering, you should ()A bunker at a normal rateB check for kinks in hoseC close valves slowlyD shut valves before topping off

考题 单选题You should frequently compare drum-mounted and remote-reading water level indicators() between these have contributed to failures because of overheating through shortage of water, when a boiler was being oil-fired.A descriptionsB discrepanciesC differentD deflections

考题 单选题Late fuel injection timing is indicated by ()A lower than normal cylinder pressure and low exhaust temperatureB lower than normal cylinder pressure and high exhaust temperatureC higher than normal cylinder pressure and low exhaust temperatureD higher than normal cylinder pressure and high exhaust temperature

考题 单选题What is NOT a function of the steam drum of a marine water-tube boiler().A Receives saturated steam from the generating tubesB Serves as a reservoir of boiler feed waterC Holds internal fittings for separation of moisture from steamD Collects steam exhausted from the turbines

考题 单选题When a sudden increase in steam demand occurs from the boiler, the water level in the drum at the higher pressure will()A rise quicklyB rise slowlyC drop quicklyD drop slowly

考题 单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A relieve excess fuel oil pressure during the “off” fire cycleB admit water to the dry pipeC throttle the forced draft fan output for proper combustionD reduce excess steam pressure in the boiler

考题 单选题The diesel engine exhaust gas bypass, as fitted with some waste heat boilers, is installed to ()A prevent engine back pressure at heavy loadsB increase total engine efficiency at low loadsC prevent boiler corrosion at low engine loadsD improve engine fuel consumption at any load

考题 单选题When ship is fouled, increasing the fuel injection for keeping the normal speed will cause the main engine ()A to work as overload characteristicB overspeedC over mechanical load onlyD over thermal load only

考题 单选题When a sudden increase in steam demand comes to normal, the drum pressure will and water level in the drum will().A rise, rise alsoB rise, dropC drop, riseD drop, drop also

考题 单选题When a diesel engine is operate at partial load, as compared to full load ,a decrease will occur in the average ()A air quantity aspiratedB fuel injection pressureC combustion pressure on the power strokeD compression on the compression stroke

考题 单选题When normal operating pressure is applied to the hydraulic oil used in a high-pressure system, the oil ().A viscosity will decreaseB volume will increaseC volume will decreaseD pour point will be reduced

考题 单选题Which one is not the normal operation for boiler shutdown?()A Carry out soot blowing if permissibleB Change fuel supply to diesel oilC Close steam stop valves on boiler when pressure is reducedD Drain boiler empty when it has cooled down

考题 单选题Large, two-stroke/cycle, main propulsion, diesel engine cylinders can be successfully pressure charged during normal operation, by using the ().A exhaust gas temperature systemB exhaust load systemC constant or pulse pressure systemD constant volume system

考题 单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A ensure feed water flow into the boilerB keep the steam drum pressure highC prevent water hammer in the feed lineD help the feed water flash to steam

考题 单选题The water level in a steaming auxiliary boiler will always ()A rise when the steam pressure is increasedB remain constant as long as the feed pump operatesC fall when the steam pressure is decreasedD vary as the steam demand changes

考题 单选题The water level showing in a boiler water gauge glass is usually () during working.A higher than the actual drum water levelB equal to the actual drum water levelC increasing due to steam condensation in the glassD lower than actual drum water level

考题 单选题Which of the following statements is correct regarding a turbocharged four-stroke/cycle diesel generator?()A At zero load the intake manifold pressure is greater than the exhaust manifold pressureB At full load the intake manifold pressure and exhaust manifold pressure are equalC At full load the intake manifold pressure is less than the exhaust manifold pressureD At full load the intake manifold pressure is greater than the exhaust manifold pressure

考题 单选题Foaming in the steam drum may be caused by () in a boiler.A oxygen in the waterB poor boiler designC density too highD excessive steam demand

考题 单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A completely drain the boiler in an emergencyB prevent sludge from forming in the drumC remove floating impurities from the boiler water surfaceD remove settled solids from the water drum

考题 单选题When attempting to restart a warm high-speed engine, which of the following reactions can you expect?()A Excessive fuelB Higher than normal temperatures for star upC Longer starting periodsD Higher than normal lube oil pressure

考题 单选题When using a fuel with a higher than normal sulfur content in an auxiliary diesel engine, you should()A maintain higher than normal jacket water temperatureB change the lube oil more frequently than normalC maintain a higher air-box temperature than normalD maintain a higher air-box pressure than normal

考题 单选题The single acting cylinder is the simplest form where pressure is applied to the full area of the piston head to move the load through piston rod extensionThe load causes rod () when the drive pressure is released.A contractionB retractionC expansionD shrinkage