Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().
A

10

B

7

C

4

D

1


参考答案

参考解析
解析: 暂无解析
更多 “单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A 10B 7C 4D 1” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

考题 The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.A.precipitate(使沉淀) silica (硅石)from solutionB.reduce corrosion in the heating coilC.prevent clogging and erosion in the coilD.maintain zero water hardness

考题 Before the seas get rough, it is a good safety practice to ______.A.secure loose gearB.move quickly about the shipC.increase lightingD.shutdown auxiliary equipment

考题 A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

考题 单选题The most common cause of scale formation in an auxiliary boiler is ()A concentrations of calcium sulfate in the boiler waterB fuel oil in the feed waterC improper treatment of the feed water with calcium sulfateD excessive feed water alkalinity

考题 单选题The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()A will be modulated in proportionB will be modulated in proportion and integralC will be modulated in proportion and differentialD will not be modulated at all

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A operating the boiler at less than normal water levelB installing fins on the firesides of water-tubesC increasing the amount of excess air to the burnersD treating the boiler water with chemical oxygen scavengers

考题 单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().A steam stop valveB dry pipeC feedwater systemD generating tubes

考题 单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A fuel pump failureB fan motor failureC increased feedwater consumptionD decreased boiler efficiency

考题 单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A firing for extended periods in the low fire modeB overheating, due to waterside depositsC varying the water level above the crown sheetD carrying excessive alkalinity in the boiler water

考题 单选题The water in an auxiliary boiler should be tested daily for ().A dissolved oxygenB chloridesC sludgeD dissolved nitrogen

考题 单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A salinity is abnormally highB steam demand is too highC water level is abnormally lowD feedwater flow is low

考题 单选题The water in an auxiliary boiler should be chemically tested daily for alkalinity and()A soap hardnessB nitrog encontentC chloride contentD dissolved CO2

考题 单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished

考题 单选题Which one is not the normal operation for boiler shutdown?()A Carry out soot blowing if permissibleB Change fuel supply to diesel oilC Close steam stop valves on boiler when pressure is reducedD Drain boiler empty when it has cooled down

考题 单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A excessive purging before lighting offB insufficient trail for ignition periodC a faulty transformer in the ignition circuitD insufficient purging before lighting off

考题 单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A monkeyB donkeyC waste heatD main

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD drum level to stabilize

考题 单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()A precipitate silica from solutionB reduce corrosion in the heating coilC prevent clogging and erosion in the coilD maintain zero water hardness

考题 单选题The water in an auxiliary boiler should be tested for chloride content to determine ().A total dissolved solidsB salt contaminationC water hardnessD chlorine contamination

考题 单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().A caustic embrittlement of the boiler metalB acidic corrosion of the boiler metalC hard scale deposits on the boiler tubesD etching of the heat exchange surfaces

考题 单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A completely drain the boiler in an emergencyB prevent sludge from forming in the drumC remove floating impurities from the boiler water surfaceD remove settled solids from the water drum

考题 单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A high steam pressure in the boilerB abnormally high feed water temperatureC abnormally high boiler water temperatureD steam demand exceeding feed pump capacity

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD dram level to stabilize

考题 单选题The water in an operating auxiliary boiler should be tested for alkalinity and chloride content each().A hourB dayC weekD month