Burner ignition failure in an automatically fired auxiliary boiler would be caused by()
A

a burned out solenoid in the oil supply valve

B

high temperature excess air

C

incorrectly setting the hot-well dump valve

D

an incorrectly positioned burner snubber realy


参考答案

参考解析
解析: 暂无解析
更多 “单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy” 相关考题
考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

考题 All of the followings are the detainable deficiencies under the SOLAS Convention except ______.A.failure of proper operation of propulsion and other essential machinery, as well as electrical installationB.failure of the proper operation of the main and auxiliary steering gearC.failure of engineering watch arrangements to conform to the requirements specified for the ship by AdministrationD.failure of the proper operation of emergency generator, lighting, batteries and switches

考题 How does foam extinguish an oil fire ?______.A.By cooling the oil below the ignition temperatureB.By removing the fuel souce from the fireC.By excluding the oxygen from the fireD.By increasing the weight of the oil

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incineratorA Ⅰ+ⅡB Ⅰ+ⅢC Ⅱ+ⅢD Ⅰ+Ⅱ+Ⅲ

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()A fuel oil supply temperature is normalB burner electrode is incorrectly positionedC fuel/air ratio is incorrectD ignition current is too low

考题 单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A fuel pump failureB fan motor failureC increased feedwater consumptionD decreased boiler efficiency

考题 单选题During waste clothes being charged into an incinerator, the auxiliary burner().A should be stopped manuallyB keeps the combustion as usualC would be cut off by an interlockD would replace the waste oil burner and keep going on

考题 单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A water in the fuel oilB broken high tension leadsC incorrect electrode settingD full fuel pressure at the nozzle

考题 单选题When does auxiliary burner of incinerator put into operation? () Ⅰ. start incinerator when it is cold Ⅱ. the sludge for dealing with is little Ⅲ. the sludge for dealing with is large Ⅳ. the water and impurity in sludge are too much Ⅴ. the temperature in incinerator is low Ⅵ. dealing with little solid rubbishA Ⅰ+Ⅱ+Ⅲ+ⅤB Ⅰ+Ⅱ+Ⅲ+ⅣC Ⅰ+Ⅳ+Ⅴ+ⅥD Ⅰ+Ⅱ+Ⅲ+Ⅵ

考题 单选题In the event of failure of an auxiliary such as a lubricating pump, the standby pump is started and put on the line automatically“the line” in this sentence refers to()A fuel manifoldB lubricating pipe lineC auxiliary engine pipe lineD generator output line

考题 单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()A cool the furnace to prevent pre-ignitionB remove explosive vapors from the furnaceC evaporate accumulated unburned fuel oilD provide sufficient air in the furnace to allow ignition of the fuel

考题 单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A excessive purging before lighting offB insufficient trail for ignition periodC a faulty transformer in the ignition circuitD insufficient purging before lighting off

考题 单选题Failure to provide _____ explanations for his frequent blunders, this young man was fired.A rationalB sentimentalC eccentricD skeptical

考题 单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A air supply is shut offB fuel supply is shut offC water supply is shut offD safety valve lifts

考题 单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()A air or water in the furnaceB combustion pulsesC fuel oil pump failureD flame failure

考题 单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A carbon deposits on the flame scannerB high fuel oil temperatureC low fuel oil viscosityD high steam pressure

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD drum level to stabilize

考题 单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A defective solenoid valveB dirty fuel nozzleC grounded high tension leadD faulty ignition cable connector

考题 单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A increased fuel consumptionB increased feed water consumptionC fuel pump failureD combustion control system failure

考题 单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A water in the fuel oilB excessive cyclingC high fuel oil pressureD improper burner maintenance

考题 单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A incorrect electrode settingB incorrect nozzle positionC clogged fuel nozzleD broken high tension lead

考题 单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A check and regulate the water levelB close the air cock once fires are litC blowdown the gage glassD crack the steam stop to assure protective steam flow

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD dram level to stabilize

考题 单选题The furnace of an oil fired boiler should be () before the operating burner is lit.A filled with waterB purgedC cleared of airD None of the above is true