网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
When does auxiliary burner of incinerator put into operation? () Ⅰ. start incinerator when it is cold Ⅱ. the sludge for dealing with is little Ⅲ. the sludge for dealing with is large Ⅳ. the water and impurity in sludge are too much Ⅴ. the temperature in incinerator is low Ⅵ. dealing with little solid rubbish
A

Ⅰ+Ⅱ+Ⅲ+Ⅴ

B

Ⅰ+Ⅱ+Ⅲ+Ⅳ

C

Ⅰ+Ⅳ+Ⅴ+Ⅵ

D

Ⅰ+Ⅱ+Ⅲ+Ⅵ


参考答案

参考解析
解析: 暂无解析
更多 “单选题When does auxiliary burner of incinerator put into operation? () Ⅰ. start incinerator when it is cold Ⅱ. the sludge for dealing with is little Ⅲ. the sludge for dealing with is large Ⅳ. the water and impurity in sludge are too much Ⅴ. the temperature in incinerator is low Ⅵ. dealing with little solid rubbishA Ⅰ+Ⅱ+Ⅲ+ⅤB Ⅰ+Ⅱ+Ⅲ+ⅣC Ⅰ+Ⅳ+Ⅴ+ⅥD Ⅰ+Ⅱ+Ⅲ+Ⅵ” 相关考题
考题 When an incinerator goes out suddenly, theosupply should be shut off quickly A.fuelB.sludgeC.airD.fuel and sludge

考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 The oil sludge is burnt in the ______onboard.I’ll show you the ashes.A.boilerB.main engineC.auxiliary engineD.incinerator

考题 In most cases,the mere reception or dumping down of the cargo on the ship ______ involve completion of loading,because the operation of loading involves all that is required to put the cargo in a condition in which it can be carried.A.is notB.has notC.do notD.does not

考题 The oil sludge is burnt in the ______onboarA.I’ll show you the ashes.B.boilerC.main engineD.auxiliary engineE.incinerator

考题 The “cure rate”of many diseases increased dramatically after penicillin was ______ by more doctors.A.put into practice B.put into effect C.put into use D.put into operation

考题 When using IP SLA FTP operation, which two FTP modes are supported? ()A、Only the FTP PUT operation type is supported.B、Active mode is supported.C、Passive FTP transfer modes are supported.D、FTP URL specified for the FTP GET operation is not supported.

考题 A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A、check for a faulty IDE cableB、be sure that the DVD+R is formatted before using itC、check for incompatible mediaD、re-install the DVD burning software

考题 单选题A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A check for a faulty IDE cableB be sure that the DVD+R is formatted before using itC check for incompatible mediaD re-install the DVD burning software

考题 单选题When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incineratorA Ⅰ+ⅡB Ⅰ+ⅢC Ⅱ+ⅢD Ⅰ+Ⅱ+Ⅲ

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A fuel pump failureB fan motor failureC increased feedwater consumptionD decreased boiler efficiency

考题 单选题During waste clothes being charged into an incinerator, the auxiliary burner().A should be stopped manuallyB keeps the combustion as usualC would be cut off by an interlockD would replace the waste oil burner and keep going on

考题 单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A water in the fuel oilB broken high tension leadsC incorrect electrode settingD full fuel pressure at the nozzle

考题 单选题When does auxiliary burner of incinerator put into operation? () Ⅰ.tart incinerator when it is cold Ⅱ.he sludge for dealing with is little Ⅲ.he sludge for dealing with is large Ⅳ.he water and impurity in sludge are too much Ⅴ.he temperature in incinerator is low Ⅵ.ealing with little solid rubbishA Ⅰ+Ⅱ+Ⅲ+ⅤB Ⅰ+Ⅱ+Ⅲ+ⅣC Ⅰ+Ⅳ+Ⅴ+ⅥD Ⅰ+Ⅱ+Ⅲ+Ⅵ

考题 单选题When the ship is in restricted visibility, the officer in charge of the engineering watch shall ensure that () Ⅰ.Bridge order relating to changes in speed or direction of operation areimmediately implemented Ⅱ.auxiliary machinery used for maneuvering is readily available Ⅲ.permanent air or steam pressure is available for sound signalsA Ⅰ+ⅡB Ⅰ+ⅢC Ⅱ+ⅢD Ⅰ+Ⅱ+Ⅲ

考题 多选题Which operation requires that you create an auxiliary instance manually before executing the operation?()ABackup-based database duplication.BActive database duplication.CTablespace point-in-time recovery.DNo operation requires the creation of an auxiliary instance.

考题 单选题Emergency generator is installed on board mainly to ()A connect to the busbar when the load increasingB supply power specially to charging panelC be put into operation during the ship arriving at or leaving portD ensure the power supply to critical equipment after the main switchboard out of power

考题 单选题Which of the following actions should normally be taken during each watch when the auxiliary boilers is in operation?()A clean the flame scanner photocell windowB Inspect and clean all solenoid valvesC lift the safety valves by handD Inspect for oil or water leaks

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD drum level to stabilize

考题 单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A defective solenoid valveB dirty fuel nozzleC grounded high tension leadD faulty ignition cable connector

考题 单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy

考题 单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A water in the fuel oilB excessive cyclingC high fuel oil pressureD improper burner maintenance

考题 单选题Concerning the incinerator’s operation, which of the following is not correct?()A Scavenging time should be more 30 seconds before ignitingB The temperature of sludge tank is 80~100℃C First igniting the incinerator with diesel oil, when the temperature of health is about 600℃, the sludge oil drawn inD The ash can be dumped into sea when the distance is more than 3 miles from land

考题 单选题When the incinerator is stopped, which of the following is wrong?()A After stopping supplying sludge oil, the value and pipe should be flushed by flushed by diesel oil and the incinerator continue burning for 10 minutesB Close auxiliary burner firstly and then close main burnerC After stopping fuel, restoring the position of main fuel supply valveD Stop blower as soon as stopping supplying fuel oil

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD dram level to stabilize

考题 单选题Which action should be taken when an auxiliary boiler in is operation?()A Clean all electrical connectionsB Lift the relief valves by handC Inspect and clean all solenoid valvesD Inspect for oil and water leaks