Excessive vibration of an automatically fired auxiliary boiler can be caused by ()
A

air or water in the furnace

B

combustion pulses

C

fuel oil pump failure

D

flame failure


参考答案

参考解析
解析: 暂无解析
更多 “单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()A air or water in the furnaceB combustion pulsesC fuel oil pump failureD flame failure” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 Which of the following problems is the main source of fuel pump and injection system malfunctions?A.Improper lubricationB.Air in the fuel systemC.Coated fuel linesD.Excessive vibration

考题 The major cause of fuel pump and injection system problems is _____.A.improper adjustmentsB.contaminated fuelC.kinked fuel linesD.excessive engine vibration

考题 A firebox explosion in an automatically fired auxiliary boiler may be the result of ______.A.excessive purging before lighting offB.insufficient trail for ignition periodC.a faulty transformer in the ignition circuitD.insufficient purging before lighting off

考题 温煮的英文是Boil。

考题 The Database Resource Manager is automatically enabled in the maintenance window that runs the Automated Maintenance Task. What is the reason for this?()  A、 to prevent the creation of an excessive number of scheduler job classesB、 to allow the Automated Maintenance Tasks to use system resources without any restrictionC、 to allow resource sharing only among the Automated Maintenance Tasks in the maintenance windowD、 to prevent the Automated Maintenance Tasks from consuming excessive amounts of system resources

考题 When youre performing a tablespace point-in-time recovery, which tablespaces will always be restored to the auxiliary instance?()A、 The SYSTEM tablespace.B、 The UNDO tablespace.C、 All tablespaces with tables.D、 All tablespaces with indexes.E、 No tablespaces are automatically restored.

考题 下面代码执行后,正确的输出结果是()。A、You are fired! You are hired!B、You are fired! You are fired!C、You are hired! You are hired!D、You are hired! Youarefired!

考题 焗的英文是()。A、RoastB、BakeC、StewD、Boil

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题Excessive vibration in an operating diesel generator may be caused by ()A electrical overloadB surging at governed RPMC loose engine mounting boltsD coolant leaking into the cylinder

考题 单选题In the event of failure of an auxiliary such as a lubricating pump, the standby pump is started and put on the line automatically“the line” in this sentence refers to()A fuel manifoldB lubricating pipe lineC auxiliary engine pipe lineD generator output line

考题 单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A firing for extended periods in the low fire modeB overheating, due to waterside depositsC varying the water level above the crown sheetD carrying excessive alkalinity in the boiler water

考题 单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()A cool the furnace to prevent pre-ignitionB remove explosive vapors from the furnaceC evaporate accumulated unburned fuel oilD provide sufficient air in the furnace to allow ignition of the fuel

考题 单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A salinity is abnormally highB steam demand is too highC water level is abnormally lowD feedwater flow is low

考题 单选题Excessive valve lash in an auxiliary diesel engine will cause the valves to open()A later and close soonerB sooner and close laterC sooner and close soonerD later and close later

考题 单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A excessive purging before lighting offB insufficient trail for ignition periodC a faulty transformer in the ignition circuitD insufficient purging before lighting off

考题 单选题Which of the terms listed below represents the operational speed at which excessive engine vibration is created?()A Non-harmonic speedB Critical speedC Maximum speedD Design maximum speed

考题 单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A air supply is shut offB fuel supply is shut offC water supply is shut offD safety valve lifts

考题 单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy

考题 单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A increased fuel consumptionB increased feed water consumptionC fuel pump failureD combustion control system failure

考题 多选题When youre performing a tablespace point-in-time recovery, which tablespaces will always be restored to the auxiliary instance?()AThe SYSTEM tablespace.BThe UNDO tablespace.CAll tablespaces with tables.DAll tablespaces with indexes.ENo tablespaces are automatically restored.

考题 单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().A caustic embrittlement of the boiler metalB acidic corrosion of the boiler metalC hard scale deposits on the boiler tubesD etching of the heat exchange surfaces

考题 单选题The Database Resource Manager is automatically enabled in the maintenance window that runs the Automated Maintenance Task. What is the reason for this?()A  to prevent the creation of an excessive number of scheduler job classesB  to allow the Automated Maintenance Tasks to use system resources without any restrictionC  to allow resource sharing only among the Automated Maintenance Tasks in the maintenance windowD  to prevent the Automated Maintenance Tasks from consuming excessive amounts of system resources

考题 单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A incorrect electrode settingB incorrect nozzle positionC clogged fuel nozzleD broken high tension lead

考题 单选题An electrically driven automatically operating auxiliary blower is provided for slow speed and () of a low speed diesel engine.A manoeuvring operationsB bad combustionC coolingD mooring trial

考题 单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A check and regulate the water levelB close the air cock once fires are litC blowdown the gage glassD crack the steam stop to assure protective steam flow