网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()
A

An HMC is required for dual VIO servers.

B

Dual VIO servers require a split backplane.

C

A dual VIO enablement code must be entered from the ASMI interface.

D

The second VIO server must be created using the IVM command line interface.


参考答案

参考解析
解析: 暂无解析
更多 “单选题A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A An HMC is required for dual VIO servers.B Dual VIO servers require a split backplane.C A dual VIO enablement code must be entered from the ASMI interface.D The second VIO server must be created using the IVM command line interface.” 相关考题
考题 A customer has many RS/6000s and POWER4 systems running different AIX applications.  What should the customer do to best position themselves for the migration to POWER5?()A、Upgrade OS to AIX 5.2.B、Implement Micro-Partitioning.C、Upgrade HMC to support POWER5.D、Install Partition Load Manager.

考题 A customer has a mixed environment of AIX on POWER4 and POWER5, and x86 based systems running a supported distribution of Linux. There is a total of 7 partitions and three standalone x86 servers. The customer wants to consolidate their applications using a single 4-core POWER6 server.  What is the minimum PowerVM edition that supports the customer requirement?()A、 PowerVM Lx86B、 PowerVM Express EditionC、 PowerVM Standard EditionD、 PowerVM Enterprise Edition

考题 A customer with a well-known brand wants to make sure they have a Green decision in their next IT infrastructure investment.   How can IBM Cool Blue help this customer? ()A、Providing tools to plan, monitor, manage, and reduce power consumption.B、Reducing cooling requirements by running CPUs at lower speeds.C、Using smart system design to create high-power servers.D、Adapting existing solutions like the Rear Door eXpander.

考题 A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 What restrictions apply to using virtual Ethernet within a cluster containing VIO clients?()A、IPAT via Aliasing must be usedB、IPAT via Replacement must be usedC、Resilience must be provided by the use of dual VIO serversD、Hardware Address Takeover (HWAT) must be used to ensure a consistent virtual MAC address

考题 A p5 570 customer is currently running AIX 5.3. The customer now wants to add Virtual Ethernet to two of the LPARs. This will enable the application tier can communicate to the database tier without using an external Ethernet card. What is the best way to accomplish this task?()A、Create a VIO serverB、Modify the LPAR profiles to add a Virtual Ethernet adapterC、Buy the Advanced Power Virtualization feature and enter a authorization code at the HMCD、Buy the Advanced Power Virtualization feature and enter a authorization code at the service processor menu

考题 A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()A、Two dual-port PCIe adaptersB、A four-port PCIe Ethernet adapterC、Four separate PCIe Ethernet adaptersD、Two embedded Integrated Virtual Ethernet adapters (IVE)

考题 Following an unscheduled power outage, theadministrator needs to power up an IVM-managed system. For the given system,what is the first step in this process?()A、Physically press the appropriate button on the system.B、Physically disconnect and reconnect the power cable on the system.C、Log into the IVM using a Web Browser, select the managed-system and select the Power on option from the Operations menu.D、Log into the HMC using a Web Browser, select the managed-system and select the Power on option from the Operations menu.

考题 A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers.   Which technology is recommended for this proposal?()A、NPIVB、vSCSIC、Arbitrated loopD、Converged adapter

考题 A customer is consolidating seven IBM i partitions onto a POWER7 system, using VIO Server to virtualize resources.Which of the following PowerVM editions is appropriate for this customer?()A、IBM i EditionB、Express EditionC、Standard EditionD、Enterprise Edition

考题 A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

考题 A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A、Dual power supplies.B、Twice the amount of disk.C、Two dual-port LHEA adapters.D、Two dual-port fibre channel adapters.

考题 A company wants a solution to consolidate their storage using the DS4000 series and implement a disaster recovery solution across two data centers linked by fibre to duplicate the production environment.The customer requires a solution with the least amount of system administration.  Which configuration would provide the best solution?()A、Implement one DS4400 at each location connected to the fibre link and use Remote Volume Mirror (RVM).B、Implement a DS4400 at each location using FlashCopy option and use host based replication to synchronize the sites.C、Implement a switched fabric using redundant SAN switches with a DS4300 using RVM option at each location.D、Implement a switched fabric using SAN switches connected via ISL with a DS4300 using RVM option at each location.

考题 A customer has a key application running in a logical partition on a POWER5 system. The customer wants the ability to run the application with minimal down time using Live Partition Mobility.  Which of the following is the minimum PowerVM edition and hardware configuration that will support the customer requirement?()A、 PowerVM Standard Edition on POWER6 hardwareB、 PowerVM Standard Edition with POWER5 hardware C、 PowerVM Enterprise Edition with POWER6 hardwareD、 PowerVM Enterprise Edition with POWER5 hardware

考题 A customer has a new Power 720 with PowerVM Standard Edition.  They plan to migrate their single-partition POWER5 550 to the new Power 720.   How can the customer migrate from the POWER5 550 to the Power 720 with minimal effort and down time?()A、Perform Live Partition Mobility between the two systems.B、Move the boot disks from the old system to the new system.C、Use Tivoli Storage Manager to back up the POWER5 550 and restore on the Power 720.D、Upgrade AIX to the latest level on the POWER5 550 and clone using the mksysb command.

考题 A customer is buying 10 new Power 720 servers and will integrate them into their existing data center which also has two Power 595s and five Power 750s, taking the total number of systems to 17. All currently installed systems are managed by a single HMC.All the machines will have dual VIO Servers for redundancy, and 10 client LPARs. How can they manage the new machines for the least cost?()A、Purchase a second HMC and use this to manage the new servers.B、Connect all of the new servers to the existing private HMC network.C、Configure a second private network on their existing HMC for the new servers.D、Connect 9 of the new servers to the existing HMC and use Integrated Virtualization Manager on the 10th.

考题 A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A、Implement PowerHA SystemMirror on both VIO servers.B、Configure Etherchannel between the client LPARs and the two VIO servers.C、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()A、VIO ServerB、AIX 5.2 ML4C、Shared Ethernet AdapterD、AIX 5.3 with Advanced Power Virtualization

考题 What is an advantage of using an HMC rather than IVM for system management?()A、Support for a single VIO Server environmentB、Adapters can be dedicated or virtual for each LPAR environmentC、Interfaces with Systems Director to manage the Power Systems serversD、Supports multiple Power Systems servers from a single point of control

考题 A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A、An HMC is required for dual VIO servers.B、Dual VIO servers require a split backplane.C、A dual VIO enablement code must be entered from the ASMI interface.D、The second VIO server must be created using the IVM command line interface.

考题 An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()A、Power 770 serversB、Power 750 serversC、Power 755 serversD、Power 720 servers

考题 单选题A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A  Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B  Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C  Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D  Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 单选题A customer is interested in using two Power 550 servers to implement a new two node cluster. The cluster willbe using SAN attached disk for shared storage and will be attached to one IP network. Which of the followingadapter configurations will meet the customer requirements while reducing single points of failure?()A AB BC CD D

考题 单选题Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()A VIO ServerB AIX 5.2 ML4C Shared Ethernet AdapterD AIX 5.3 with Advanced Power Virtualization

考题 单选题A customer has a mixed environment of AIX on POWER4 and POWER5, and x86 based systems running a supported distribution of Linux. There is a total of 7 partitions and three standalone x86 servers. The customer wants to consolidate their applications using a single 4-core POWER6 server.  What is the minimum PowerVM edition that supports the customer requirement?()A  PowerVM Lx86B  PowerVM Express EditionC  PowerVM Standard EditionD  PowerVM Enterprise Edition

考题 单选题A customer wants to implement the Software Inventory capabilities of IBM Director in their environment of 50 servers, 500 laptops and 150 desktops.Which of the following would represent a minimum valid configuration to support this solution?()A Windows 2000 server with 2GB free space, 2GB RAM and dual 1 GHz proc, using Access 2003B Linux with 2.6 kernel and 2GB free space, 2GB RAM and dual 1 GHz proc, using MySQLC Windows 2000 server with 2GB free space, 2GB RAM, dual 1 GHz proc with SMBIOS using MS Jet databaseD Windows 2003 server with 2GB free space, 2GB RAM, dual 1 GHz proc with SMBIOS using MS SQL database

考题 单选题A new customer wants to install a Power 750 in a warehouse location that has no local staff to support it. They are concerned about hardware support and would like to have the system notify IBM service if there is an issue.Which actions will address the customer concern?()A Enable automatic problem reporting from smitB Use IVM to enable console mirroring to IBM Remote Support.C Use the HMC to enable reporting through Electronic Service Agent.D Enable Automatic Problem Reporting in ASMI using he embedded modem on the FSP.

考题 单选题A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A An HMC is required for dual VIO servers.B Dual VIO servers require a split backplane.C A dual VIO enablement code must be entered from the ASMI interface.D The second VIO server must be created using the IVM command line interface.