网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
In an operating refrigeration system low on refrigerant, a liquid line sight glass will()
A

be clear

B

be blue

C

be light green

D

show bubbles


参考答案

参考解析
解析: 暂无解析
更多 “单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles” 相关考题
考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题A refrigerant boils and vaporizes in the () in a compression refrigeration system.A liquid receiverB compressorC condenserD cooling coil

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A be clearB be blueC be light greenD show bubbles

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A compressorB condenserC receiverD evaporator

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A too much refrigerant in the systemB oil entrained in the refrigerantC less than a full charge of refrigerant in the systemD ice crystals forming in the refrigerant

考题 单选题Moisture is removed from a refrigeration system by().A bleeding refrigerant from the condenserB opening a drain petcock on the oil separatorC condensing the water in the heat exchangerD using a dehydrator cartridge

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题In which of the listed refrigeration system components does superheating of the refrigerant take place?()A Expansion valveB EvaporatorC DrierD Receiver

考题 单选题Refrigerant is circulated through a refrigeration system by the ().A compressorB condenserC expansion valveD evaporator

考题 单选题Saltwater is typically provided to a refrigeration system to ().A cool the expansion valveB prevent refrigerant superheatingC condense the refrigerant gasD prevent motor overheating

考题 单选题One cause of high head pressure occurring in a refrigeration system can be ().A insufficient cooling water flow to the condenserB a low refrigerant charge in the systemC the liquid valve is open too muchD high evaporator superheat

考题 单选题Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()A Sub-cooled liquidB Sub-cooled vaporC Superheated vaporD Liquid

考题 单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().A sub-cooled liquidB high temperature liquidC oil saturated liquidD superheated vapor

考题 单选题To add refrigerant to the low side of an air conditioning system, the refrigerant should be introduced through the ()A suction service valve as a vaporB suction service valve as a liquidC discharge service valve as a vaporD charging valve as a liquid

考题 单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A liquidB dry saturated gasC wet saturated gasD superheated vapor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()A Expansion valveB CondenserC EvaporatorD Compressor

考题 单选题The presence of bubbles in a refrigeration system liquid line may ().A promote refrigerant dehydrationB be absorbed in the receiverC cause low condensing pressureD carry moisture and lead to corrosion

考题 单选题Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause ().A carbon deposits on the compressor suction valvesB the evaporator temperature to increaseC rapid corrosion of the thermal expansion valveD no operating problems