网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The boiler is fired () the demand for steam exceeds that available from exhaust gas heating.
A

whenever

B

however

C

wherever

D

whether


参考答案

参考解析
解析: 暂无解析
更多 “单选题The boiler is fired () the demand for steam exceeds that available from exhaust gas heating.A wheneverB howeverC whereverD whether” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

考题 On traffic lanes where demand is strong and plane capacity is limited, the air rates will be ()and vice versa for traffic lanes where supply exceeds demand.A、lowB、highC、normalD、average

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().A yellowish flameB golden yellow flameC white flameD brilliant white flame

考题 单选题The steam boiler is part of a closed loop steam, whereby, after the energy of the steam is used up and it becomes water again, () is collected and returned back to the boiler for heating up again to steam.A the formerB the firstC the latterD the last

考题 单选题What is NOT a function of the steam drum of a marine water-tube boiler().A Receives saturated steam from the generating tubesB Serves as a reservoir of boiler feed waterC Holds internal fittings for separation of moisture from steamD Collects steam exhausted from the turbines

考题 单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().A steam stop valveB dry pipeC feedwater systemD generating tubes

考题 单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A salinity is abnormally highB steam demand is too highC water level is abnormally lowD feedwater flow is low

考题 单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished

考题 单选题Which one is not the normal operation for boiler shutdown?()A Carry out soot blowing if permissibleB Change fuel supply to diesel oilC Close steam stop valves on boiler when pressure is reducedD Drain boiler empty when it has cooled down

考题 单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A monkeyB donkeyC waste heatD main

考题 单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()A air or water in the furnaceB combustion pulsesC fuel oil pump failureD flame failure

考题 单选题A feed pump for an auxiliary boiler might lose suction if the ().A boiler water level is lowB feedwater is too hotC boiler steam demand is lowD feedwater is too cold

考题 单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A ensure feed water flow into the boilerB keep the steam drum pressure highC prevent water hammer in the feed lineD help the feed water flash to steam

考题 单选题The water level in a steaming auxiliary boiler will always ()A rise when the steam pressure is increasedB remain constant as long as the feed pump operatesC fall when the steam pressure is decreasedD vary as the steam demand changes

考题 单选题() should be tested and adjusted when the boiler survey is carried out.A The boiler oil tankB The steam pipeC The fire sideD The safety valves

考题 单选题(), iea steam cooler, may be filled in the boiler system to control the superheated steam temperature.A An economizerB An attemperatorC A water dramD A down-comer tube

考题 单选题Foaming in the steam drum may be caused by () in a boiler.A oxygen in the waterB poor boiler designC density too highD excessive steam demand

考题 单选题When steam is being raised on a boiler, the water level will normally ().A drop as the boiler warms upB rise as the boiler warms upC remain unchanged until the boiler is hot enoughD rise and fall with the steam demand

考题 单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A incorrect electrode settingB incorrect nozzle positionC clogged fuel nozzleD broken high tension lead

考题 单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A high steam pressure in the boilerB abnormally high feed water temperatureC abnormally high boiler water temperatureD steam demand exceeding feed pump capacity

考题 单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A check and regulate the water levelB close the air cock once fires are litC blowdown the gage glassD crack the steam stop to assure protective steam flow

考题 单选题The furnace of an oil fired boiler should be () before the operating burner is lit.A filled with waterB purgedC cleared of airD None of the above is true