网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Each fire pump on a ship must have a pressure gauge located at().
A

the pump discharge

B

the manifold connection

C

each fire station discharge

D

the pump station


参考答案

参考解析
解析: 暂无解析
更多 “单选题Each fire pump on a ship must have a pressure gauge located at().A the pump dischargeB the manifold connectionC each fire station dischargeD the pump station” 相关考题
考题 Which action is routinely performed at the annual servicing and inspection of a dry-chemical cartridge-operated portable fire extinguisher?A.Test the pressure gauge for correct readingB.Weigh the cartridgeC.Replace the dry chemicalD.Pressure test the discharge hose

考题 During a fire drill on a vessel, what action is required? ______.A.Start each fire pump.B.Launch and run a lifeboat.C.Inventory rescue and fire equipment.D.Inspect fire hoses

考题 Each ship having an inert gas system must have a portable instruments to measure concentrations of hydrocarbon vapor in inert atmospheres and also to measure ______.A.nitrogenB.oxygenC.carbon dioxideD.water vapor

考题 单选题Each inert gas system gas main must have an automatic shut down valve at the outlet of the gas production plant. This valve must close automatically upon().A cargo pump failureB blower failureC deck seal low water levelD low inert gas temperature

考题 单选题The signal for fire alarm on a ship must be indicated().A at each alarm bellB at each alarm actuatorC near all exitsD on the station bill

考题 单选题On a ship,a fire pump may be used for other purposes if().A the other services are run off a reducing station with a pressure gageB a separate fire pump is available for use on the fire mainC all other services are operated by a manifold near the pumpD All of the above

考题 单选题The discharge side of every fire pump must be equipped with a().A gate valveB pressure gaugeC check valveD strainer

考题 单选题Each hand portable,semi-portable and fixed fire extinguishing unit on a ship must be tested and inspected at least once every().A six weeksB six monthsC twelve monthsD two years

考题 单选题During a fire drill on a vessel, what action is required?()A Start each fire pumpB Launch and run a lifeboatC Inspect fire hosesD Close each fire pump

考题 单选题Before operating a non-oceangoing ship greater than 100 gross tons it must have a fixed piping system to discharge oily mixtures ashore. This system must include().A approved oily-water separating equipmentB a fixed or portable containment system at the shore connectionC a spare pump in case the main pump is inoperativeD at least one outlet accessible from the weather deck

考题 单选题A ship helicopter landing deck on which fueling operations are conducted must have a fire protection system that is capable of discharging at 100 psi pressure a foam spray of at least().A 30 gallons per minuteB 40 gallons per minuteC 50 gallons per minuteD 60 gallons per minute

考题 单选题Each fireman’s outfit and its spare equipment on a ship must be stowed().A in a locked cabinet in the machinery spaceB in an unlocked cabinet in the machinery spaceC in a separate and accessible locationD at a fire hydrant location

考题 单选题The pressure difference of the gauge on the oily water separator increases greatly, the reason is()A the filter is cloggedB bilge suction value is cloggedC suction value and discharge value of the pump do not open fullyD screw pump is worn seriously and volumetric efficiency is decreased

考题 单选题A pump is said to have "negative suction head" when the pump is located ().A between the suction and dischargeB below the liquid supplyC above the liquid supplyD any of the above

考题 单选题Each fire pump on a tanker must have a pressure gauge located at().A the pump dischargeB the manifold connectionC each fire station dischargeD the pump station

考题 单选题The air reservoirs must have () fitted to prevent rupture in the event of fire.A high pressure alarmB fire alarmC extinguishersD fusible plugs

考题 单选题During a fire drill on a ship,what action is required?()A Start each fire pumpB Launch and run a lifeboatC Inventory rescue and fire equipmentD Inspect fire hoses

考题 单选题Each part of the fire-main system located on an exposed deck must be().A protected against freezingB locked to prevent theftC numbered sequentiallyD pressurized at all times

考题 单选题Each fire hose coupling on a ship must have threads that meet the specifications of the().A American Petroleum InstituteB National Standard Fire hose CouplingC American Society of Mechanical EngineersD Underwriter's Laboratories,Inc

考题 单选题Each fire hose coupling on a ship must have threads that meet the specifications of the().A American Petroleum InstituteB National Standard Firehose CouplingC American Society of Mechanical EngineersD Underwriter's Laboratories,Inc

考题 单选题According to regulations,a cargo hose used for transferring liquefied gases must have a bursting pressure of().A 5 times the maximum working pressure on the hose during cargo transferB one half the designed working pressureC 4 times the pressure of the cargo pump used for transferringD 5 times the minimum working pressure on the hose during cargo transfer

考题 单选题Each fire hydrant must have at least one spanner and at least one().A hose rack or reelB all purpose nozzleC foam applicatorD pick axe

考题 单选题A fire main system must have enough fire hydrants so that each accessible space may be sprayed with().A a low velocity spray applicatorB a water spray or solid streamC at least two spray patterns of waterD at least 25 psi delivered pressure

考题 单选题A branch line valve of a fire extinguishing system on a ship must be marked with the().A maximum pressure allowed at that branchB name of the space or spaces which it servesC date of the last maintenance inspectionD pressure needed to maintain an effective stream at that point

考题 单选题Each hand portable fire extinguisher on a ship must be marked with().A the name of the unit on which it is locatedB the date that it was installed on the unitC the names of the individuals qualified to use itD an identification number different from other extinguishers on the unit

考题 单选题Each ship having an inert gas system must have a portable instruments to measure concentrations of hydrocarbon vapor in inert atmospheres and also to measure().A nitrogenB oxygenC carbon dioxideD water vapor

考题 单选题Where foam extinguishing systems are provided on a ship,each machinery flat in the protected space must have a(n)().A coamingB alarmC drainD fire sensor