When the refrigeration demand is small,_______.

A.the expansion valve will move toward the wide open position

B.the expansion valve will move toward the closing position

C.the feeler bulb will conveys the high temperature

D.the superheat degree will raise


参考答案

更多 “ When the refrigeration demand is small,_______.A.the expansion valve will move toward the wide open positionB.the expansion valve will move toward the closing positionC.the feeler bulb will conveys the high temperatureD.the superheat degree will raise ” 相关考题
考题 Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve

考题 The expansion valve used in a refrigeration system regulates theA.superheat of the gas leaving the compressorB.back pressure in the evaporatorC.temperature in the refrigerated spaceD.degree of superheat of the gas leaving the evaporator

考题 Which action must be taken when an individual cargo tank is closed off from the inert gas system by the tank isolation valve?A.The tank must be gas freedB.The tank must be ballastedC.The tank must be vented to the atmosphereD.The bypass valve must also be closed

考题 Hurricanes may move in any direction.However,it is rare and generally of short duration when a hurricane in the Northern Hemisphere moves toward the ______.A.West or northwestB.NortheastC.SoutheastD.North

考题 单选题If a refrigeration system compressor crankcase is sweating, you should ().A add refrigerant to the systemB adjust the thermal expansion valve to the proper settingC adjust the float valve to the proper holding pressureD open the hand expansion valve

考题 单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A Shortage of refrigerant oilB Slight shortage of refrigerantC Excessive condenser cooling water flowD Faulty expansion valve

考题 单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.A compressorB condenserC throttle valveD evaporator

考题 单选题The scale trap is located between the ()A king valve and the expansion valveB solenoid valve and expansion valveC evaporator and receiverD compressor and evaporator

考题 单选题What is the function of thermostatic expansion valve in a compression refrigeration system?()A nonexistentB for controlling pressureC for controlling superheatD for controlling the solenoid valve

考题 单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then close until the compressor restartsD always be completely closed until the compressor restarts

考题 单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()A The liquid receiver functions to collect and remove non-condensable gasesB A thermostatic expansion valve is used to control refrigerated space temperatureC Refrigerant temperature in an evaporator is directly related to refrigerant pressureD Dehydrators must be used continuously in a refrigeration system

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题Moisture in a refrigeration system can cause ().A freezing the expansion valve closedB corrosion of system pipingC improper temperature regulationD all of the above

考题 单选题When the heat load begins to increase, the needle valve of an expansion valve will()A move in an opening directionB move in a closing directionC either open or closeD not move at all

考题 单选题A solenoid valve used in a refrigeration system should be installed ().A with the axis of the solenoid horizontal, sensing temperature of the box, and upstream of the thermal expansion valveB upright, sensing temperature of the box, and upstream of the thermal expansion valveC upright, sensing temperature of the box, and downstream of the thermal expansion valveD upright, sensing heat of the tail coil, and upstream of the thermal expansion valve

考题 单选题Which of the listed statements is correct concerning refrigeration systems?()A Dehydrators must be used continuously in a refrigeration systemB A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursC A thermostatic expansion valve is used to control refrigerated space temperatureD The liquid receiver functions to collect and remove non- condensable gases

考题 单选题When the refrigeration demand is small,()A the expansion valve will move toward the wide open positionB the expansion valve will move toward the closing positionC the feeler bulb will conveys the high temperatureD the superheat degree will raise

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser

考题 单选题Constant superheat is maintained at the evaporator outlet of a refrigeration coil by a()A solenoid valveB low pressure cutout switchC king valveD thermal expansion valve

考题 单选题In a refrigeration system, if the cooling water to the condenser fails, the().A box temperature solenoid valve will closeB expansion valve will closeC compressor will shutdownD king valve will open

考题 单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().A re-adjust the discharge pressureB clean the expansion valve screenC add refrigerantD adjust the expansion valve

考题 单选题The low pressure side of a refrigeration system is considered to exist from the ().A expansion valve to the compressorB receiver to the expansion coilC expansion valve to the evaporatorD condenser to the expansion valve

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve

考题 单选题A pressure drop in the liquid line of a refrigeration system may cause()A the solenoid valve to seizeB the compressor to huntC flash gas to form in the liquid lineD the expansion valve to freeze open

考题 单选题When a refrigeration compressor motor fails to start, the FIRST thing that should be checked for is a ().A loose expansion valve control bulbB low differential setting on the H-PcutoutC blown fuse in the motor circuitD faulty suction pressure regulator

考题 单选题Hurricanes may move in any direction.However,it is rare and generally of short duration when a hurricane in the Northern Hemisphere moves toward the().A West or northwestB NortheastC SoutheastD North

考题 单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A Thermal expansion valve frozen openB Suction gas heat exchanger bypassedC Condenser clogged or fouledD High pressure cutout switch inoperative