网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
When the refrigeration demand is small,_______.
A.the expansion valve will move toward the wide open position
B.the expansion valve will move toward the closing position
C.the feeler bulb will conveys the high temperature
D.the superheat degree will raise
参考答案
更多 “ When the refrigeration demand is small,_______.A.the expansion valve will move toward the wide open positionB.the expansion valve will move toward the closing positionC.the feeler bulb will conveys the high temperatureD.the superheat degree will raise ” 相关考题
考题
Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve
考题
The expansion valve used in a refrigeration system regulates theA.superheat of the gas leaving the compressorB.back pressure in the evaporatorC.temperature in the refrigerated spaceD.degree of superheat of the gas leaving the evaporator
考题
Which action must be taken when an individual cargo tank is closed off from the inert gas system by the tank isolation valve?A.The tank must be gas freedB.The tank must be ballastedC.The tank must be vented to the atmosphereD.The bypass valve must also be closed
考题
Hurricanes may move in any direction.However,it is rare and generally of short duration when a hurricane in the Northern Hemisphere moves toward the ______.A.West or northwestB.NortheastC.SoutheastD.North
考题
单选题If a refrigeration system compressor crankcase is sweating, you should ().A
add refrigerant to the systemB
adjust the thermal expansion valve to the proper settingC
adjust the float valve to the proper holding pressureD
open the hand expansion valve
考题
单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A
Shortage of refrigerant oilB
Slight shortage of refrigerantC
Excessive condenser cooling water flowD
Faulty expansion valve
考题
单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.A
compressorB
condenserC
throttle valveD
evaporator
考题
单选题The scale trap is located between the ()A
king valve and the expansion valveB
solenoid valve and expansion valveC
evaporator and receiverD
compressor and evaporator
考题
单选题What is the function of thermostatic expansion valve in a compression refrigeration system?()A
nonexistentB
for controlling pressureC
for controlling superheatD
for controlling the solenoid valve
考题
单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A
always be wide open when the compressor restartsB
continue to operate as if the system were in operationC
remain open until evaporator pressure equalizes, then close until the compressor restartsD
always be completely closed until the compressor restarts
考题
单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()A
The liquid receiver functions to collect and remove non-condensable gasesB
A thermostatic expansion valve is used to control refrigerated space temperatureC
Refrigerant temperature in an evaporator is directly related to refrigerant pressureD
Dehydrators must be used continuously in a refrigeration system
考题
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A
Condenser and thermal expansion valveB
King and solenoid valvesC
Compressor and thermal expansion valveD
Condenser and solenoid valve
考题
单选题Moisture in a refrigeration system can cause ().A
freezing the expansion valve closedB
corrosion of system pipingC
improper temperature regulationD
all of the above
考题
单选题When the heat load begins to increase, the needle valve of an expansion valve will()A
move in an opening directionB
move in a closing directionC
either open or closeD
not move at all
考题
单选题A solenoid valve used in a refrigeration system should be installed ().A
with the axis of the solenoid horizontal, sensing temperature of the box, and upstream of the thermal expansion valveB
upright, sensing temperature of the box, and upstream of the thermal expansion valveC
upright, sensing temperature of the box, and downstream of the thermal expansion valveD
upright, sensing heat of the tail coil, and upstream of the thermal expansion valve
考题
单选题Which of the listed statements is correct concerning refrigeration systems?()A
Dehydrators must be used continuously in a refrigeration systemB
A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursC
A thermostatic expansion valve is used to control refrigerated space temperatureD
The liquid receiver functions to collect and remove non- condensable gases
考题
单选题When the refrigeration demand is small,()A
the expansion valve will move toward the wide open positionB
the expansion valve will move toward the closing positionC
the feeler bulb will conveys the high temperatureD
the superheat degree will raise
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题Constant superheat is maintained at the evaporator outlet of a refrigeration coil by a()A
solenoid valveB
low pressure cutout switchC
king valveD
thermal expansion valve
考题
单选题In a refrigeration system, if the cooling water to the condenser fails, the().A
box temperature solenoid valve will closeB
expansion valve will closeC
compressor will shutdownD
king valve will open
考题
单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().A
re-adjust the discharge pressureB
clean the expansion valve screenC
add refrigerantD
adjust the expansion valve
考题
单选题The low pressure side of a refrigeration system is considered to exist from the ().A
expansion valve to the compressorB
receiver to the expansion coilC
expansion valve to the evaporatorD
condenser to the expansion valve
考题
单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A
The condenser and the expansion valveB
The king valve and the solenoid valveC
The compressor and the expansion valveD
The condenser and the solenoid valve
考题
单选题A pressure drop in the liquid line of a refrigeration system may cause()A
the solenoid valve to seizeB
the compressor to huntC
flash gas to form in the liquid lineD
the expansion valve to freeze open
考题
单选题When a refrigeration compressor motor fails to start, the FIRST thing that should be checked for is a ().A
loose expansion valve control bulbB
low differential setting on the H-PcutoutC
blown fuse in the motor circuitD
faulty suction pressure regulator
考题
单选题Hurricanes may move in any direction.However,it is rare and generally of short duration when a hurricane in the Northern Hemisphere moves toward the().A
West or northwestB
NortheastC
SoutheastD
North
考题
单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A
Thermal expansion valve frozen openB
Suction gas heat exchanger bypassedC
Condenser clogged or fouledD
High pressure cutout switch inoperative
热门标签