网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every ()
A

week

B

2 weeks

C

month

D

3 months


参考答案

参考解析
解析: 暂无解析
更多 “单选题An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every ()A weekB 2 weeksC monthD 3 months” 相关考题
考题 describe the procedure to start an emergency generator ?

考题 The emergency generator or emergency battery is connected to _______on most large ships.A.distribution boardsB.section boardsC.emergency switch boardsD.main switch boards

考题 It ______ for an emergency generator to require paralleling.A.is not usualB.is usualC.is necessaryD.is not impossible

考题 Prior to getting underway,the Master or person in charge of a vessel must ______.A.conduct a fire drillB.conduct a boat drillC.log the fore and aft draft marksD.test the emergency generator

考题 Most pedestal crane power is provided by ______.A.Electro-hydraulic unitsB.Steam unitsC.Independent internal combustion power unitsD.All of the above

考题 What is a requirement for remote manual shutdown stations for internal combustion engine driven cargo pumps on tank barges ________.A.They must be conspicuously markedB.They must be located at least 10 feet from the engineC.There must be at least two such shutdown devicesD.The valve rods shall be fitted with stuffing boxes

考题 单选题Each emergency generator on a mobile offshore drilling unit,when tested,must be run under a full load for at least().A one hourB two hoursC ten hoursD four hours

考题 单选题For most diesel propulsion and generator engines, the over-speed trip device will stop the engine by ()A moving the governor control to stopB shutting off the lubricating oil supplyC tripping the governor emergency stop leverD shutting off the fuel supply

考题 单选题Prior to getting underway,the Master or person in charge of a vessel must().A conduct a fire drillB conduct a boat drillC log the fore and aft draft marksD test the emergency generator

考题 单选题A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()A an electrical interlock systemB an automatic paralleling trip switchC the synchronizing oscilloscopeD the reverse current relay

考题 单选题An emergency diesel generator should automatically shut down in the event of ()A dangerous over-speedingB a loss of lube oil pressureC activation of the fixed CO2 system for the emergency generator spaceD all of the above

考题 单选题Gas exchange, which is a basic part of the cycle of an internal combustion engine, is()A the supply of normal air and removal of compressed airB the supply of fuel oil and combustion of the atomized oilC the supply of fresh air and removal of exhaust gasesD the supply of fresh air and removal of the extra heat

考题 单选题Which()need NOT be entered in the Official Logbook?A The testing of the internal combustion engine driven emergency generators at least once each month the vessel is navigatedB The testing of storage batteries for emergency lighting and power systems once each 6 months the vessel is navigatedC The actual draft when the vessel arrives in salt water after departing a portD The testing of the line-throwing appliance once every 3 months

考题 单选题()of the following need not be entered in the official logbook?A The testing of the internal combustion engine driven emergency generator at least once each month the vessel is navigatedB The testing of storage betteries for emergency lighting and systems once each 6 months the vessels is navigatedC The actual draft when the vessel arrives in salt water after department a portD The testing of the line-throwing appliance once every 3 months

考题 单选题In a modern internal combustion diesel engine, the load carrying part of the engine is referred to as the()A bedplate or baseB sump or oil panC cylinder blockD frame

考题 单选题Internal combustion engine crankcase vent outlets must be equipped with ()A hinged rain guardsB corrosion resistant flame screensC dipsticks for measuring oil levelsD crankcase ventilation fans

考题 单选题Which of the listed sections of an emergency switchboard is used to supply power for alarm signals under emergency conditions?()A The generator and bus transfer sectionB The 450 volt, 60 cycle, 3 phase busC The 120 volt, 3 phase, 60 cycle busD The 24 volt DC bus

考题 单选题The booster pump, which supplies diesel oil to() , should have a possibility of being powered by compressed air or by emergency power.A the main enginesB the auxiliary enginesC the emergency generator engineD the auxiliary engines and the main engine(s)

考题 单选题Standby or emergency diesel generator day tanks should always be kept full to reduce the possibility of()A sediment contaminationB fuel filter cloggingC moisture formationD inadequate transfer pump suction head

考题 单选题Since the burning or combustion takes place within the engine itself, the engine is known as ().A a fire -tube boilerB an internal combustion engineC an external combustion engineD an internal combustion generator

考题 单选题()is not a part of the main switch board.A Control panel of main generatorB Control panel of emergency generatorC Paralleling panelD Load panel of main generator

考题 单选题The emergency generator or emergency battery is connected to() on most large ships.A distribution boardsB section boardsC emergency switch boardsD main switch boards

考题 单选题During the watch keeping at sea, at appropriate intervals inspection should be made of (), auxiliary machinery and steering gear spaces by the duty engineer.A the main propulsion plantB lifesaving jacketsC lifeboat engineD state of emergency generator

考题 单选题The main operating characteristic of diesel engines which distinguishes them from other internal combustion engines is the ()A method of supplying airB cooling systemC method of igniting fuelD valve operating mechanism

考题 单选题It () for an emergency generator to require paralleling.A is usualB is not usualC is necessaryD is not impossible

考题 单选题On a ship,each emergency generator must be tested at least once each().A weekB monthC three monthsD six months

考题 单选题The exhaust ports are located around the lower part of the cylinder liner, ()the products of combustion are driven by scavenging air.A in whichB by whichC through whichD from which