网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive.  Which of the following is the MOST likely cause of the failures?()
A

 The backplane has failed and needs to be replaced.

B

 The array must be disbanded and recreated from a backup source to recognize the replacement drive.

C

 There is a conflict with the optical drive on the server.

D

 The server power supply is failing and not providing enough power for all the drives.


参考答案

参考解析
解析: 暂无解析
更多 “单选题A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive.  Which of the following is the MOST likely cause of the failures?()A  The backplane has failed and needs to be replaced.B  The array must be disbanded and recreated from a backup source to recognize the replacement drive.C  There is a conflict with the optical drive on the server.D  The server power supply is failing and not providing enough power for all the drives.” 相关考题
考题 There is a power outage and all servers are shut down properly by the uninterruptible power supply (UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors, 16GB of memory, and a RAID 5 array with 10 drives.Which of the following is the MOST likely cause?()A. A failed RAID controllerB. Two failed processorsC. Two failed sticks of memoryD. Two failed drives

考题 Which of the following storage tools could be used to initiate the rebuilding of a failed hard drive?() A. RAID array managementB. CHKDSKC. Monitoring agentsD. Partitioning management

考题 After performing the initial steps in installing the server OS from a DVD-ROM, the server reboots and goes back into the setup wizard. Which of the following is the MOST likely cause for this problem?()A、The DVD-ROM drive has failed.B、An installation file copied from the DVD to the hard drive is corrupt.C、Faulty OS installation DVDD、Incorrect boot sequence in the BIOS

考题 A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive.  Which of the following is the MOST likely cause of the failures?()A、 The backplane has failed and needs to be replaced.B、 The array must be disbanded and recreated from a backup source to recognize the replacement drive.C、 There is a conflict with the optical drive on the server.D、 The server power supply is failing and not providing enough power for all the drives.

考题 A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()A、 Edit the boot.ini file.B、 Change to a hardware RAID solution.C、 Recreate the array.D、 Edit the active drive in the array.

考题 An administrator has removed a SATA hard drive from a failed server. Which of the following adapters would MOST likely be used by the administrator to transfer files from the drive to a laptop?()A、SATA to SCSIB、SATA to HBAC、SATA to USBD、SATA to SAS

考题 Which of the following storage tools could be used to initiate the rebuilding of a failed hard drive?()A、RAID array managementB、CHKDSKC、Monitoring agentsD、Partitioning management

考题 Upgrading which of the following components in a server has the GREATEST affect on virtualization?()A、Amount of MemoryB、Number of HBAsC、Hard drive cache sizeD、ECC ability in memory

考题 A disk drive failed in a RAID 5 array.  After replacing the disk drive, users are still reporting that access to the server is very slow.  Which of the following BEST explains the problem?()A、The array is rebuilding.B、The array must be reconfigured.C、The array is corrupt.D、The disk drive is not compatible.

考题 A user reports that their hard drive has failed and needs to be replaced. Which of the following should the technician do FIRST?()A、Run the hard disk manufacturer’s diagnostic programB、Re-image the driveC、Replace the hard drive and load WindowsD、Ask the user diagnostic questions

考题 Which of the following MOST correctly describes a hot spare?()A、A drive assigned to an array that will only hold parity information used for rebuilding a failedarray drive.B、An external hard drive to which all data is replicated to for recovery in the event of a failure.C、A drive assigned to an array that will automatically be used to rebuild a failed array drive.D、An extra drive purchased and stored in the parts cabinet to replace failed drives.

考题 The technician is working on a system and has determined that the hard drive must be reimaged. However, the customer wants to retain all the data. Which of the following would take the LEAST amount of time to implement?()A、Create a new partition on the hard drive, copy all data to the new partition, reimage the drive, and the old data will be on the new partition and accessible.B、Install a new hard drive, slave the old drive, image the new drive, and show the customer how to access their data on the old drive.C、Upload the data to an external FTP server, reimage the drive, and then restore the data to the newly imaged drive.D、Copy data to a USB connected hard drive, reimage the drive, and then restore the data to the newly imaged drive.

考题 There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives.  Which of the following is the MOST likely cause?()A、 A failed RAID controllerB、 Two failed processorsC、 Two failed sticks of memoryD、 Two failed drives

考题 A SAN attached production file server is required to be backed up nightly according to company  policy.Recently the data to be backed up has increased to approximately 4TB. Currently, the server has a single attached LTO2 tape drive.  Which of the following should the server administrator do to provide enough backup capacity for the nightly job? ()A、 Replace the backup software with a more efficient application.B、 Reduce the amount of data to be backed up.C、 Replace the LTO2 tape drive with an LTO3 tape drive.D、 Replace the single tape drive with a tape library.

考题 An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed.  Which of the following is the MOST likely cause?()A、 Corrupt file system tableB、 Backplane failureC、 Multiple drive failureD、 Bad cable

考题 An administrator has replaced a faulty drive in a server using software RAID. The drive needs to now be partitioned before being added back to the array. Which of the following tools should the administrator use to accomplish this?()A、chkdskB、mountC、fsckD、diskpart

考题 单选题Which of the following MOST correctly describes a hot spare?()A A drive assigned to an array that will only hold parity information used for rebuilding a failedarray drive.B An external hard drive to which all data is replicated to for recovery in the event of a failure.C A drive assigned to an array that will automatically be used to rebuild a failed array drive.D An extra drive purchased and stored in the parts cabinet to replace failed drives.

考题 单选题You need to improve the speed of backups on SQL1. Management has approved the purchase of additional hard disks for this server. What should you do?()A Configure the hard disks as a RAID-0 array, and store the backups on this new array.B Configure the hard disks as a RAID-5 array, and store the backups on this new array.C Configure the hard disks as a RAID-10 array, and store the backups on this new array.D Configure the hard disks as a spanned volume, and store the backups on this new volume.E Use the hard disks to extend the volume that currently holds SQL Server backups.

考题 单选题Which of the following storage tools could be used to initiate the rebuilding of a failed hard drive?()A  RAID array managementB  CHKDSKC  Monitoring agentsD  Partitioning management

考题 单选题An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed.  Which of the following is the MOST likely cause?()A  Corrupt file system tableB  Backplane failureC  Multiple drive failureD  Bad cable

考题 单选题A SAN attached production file server is required to be backed up nightly according to company  policy.Recently the data to be backed up has increased to approximately 4TB. Currently, the server has a single attached LTO2 tape drive.  Which of the following should the server administrator do to provide enough backup capacity for the nightly job? ()A  Replace the backup software with a more efficient application.B  Reduce the amount of data to be backed up.C  Replace the LTO2 tape drive with an LTO3 tape drive.D  Replace the single tape drive with a tape library.

考题 单选题After performing the initial steps in installing the server OS from a DVD-ROM, the server reboots and goes back into the setup wizard. Which of the following is the MOST likely cause for this problem?()A The DVD-ROM drive has failed.B An installation file copied from the DVD to the hard drive is corrupt.C Faulty OS installation DVDD Incorrect boot sequence in the BIOS

考题 单选题After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()A Replace the second drive with a hot swappable one.B Swap the drive boot order in the BIOSC Make the second disk active under the disk management tool.D Rebuild the array using the hardware RAID tool at boot.

考题 单选题After a server inspection, an administrator notices a single drive failure on a server configured with RAID 5. Which of the following is the NEXT step to start rebuilding the array?()A Reestablish the mirror array.B Perform online volume expansion.C Insert hot plug drive.D Move data to another volume.

考题 单选题A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()A  Edit the boot.ini file.B  Change to a hardware RAID solution.C  Recreate the array.D  Edit the active drive in the array.

考题 单选题A system administrator has a failed disk drive that is mirrored to another disk drive. They successfully removed the logical volume copies off of the failed disk drive. Which of the following commands should be used to remove the failed disk drive from the volume group?()A chvgB rmdevC reducevgD exportvg

考题 单选题A disk drive failed in a RAID 5 array.  After replacing the disk drive, users are still reporting that access to the server is very slow.  Which of the following BEST explains the problem?()A The array is rebuilding.B The array must be reconfigured.C The array is corrupt.D The disk drive is not compatible.