网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()
A

4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server 

B

Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module 

C

Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module 

D

Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A 4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server B Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module C Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module D Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server” 相关考题
考题 An administrator wants to host several LPARs on a JS23 Blade server.To achieve this what additional management software is required?() A.HMCB.IVMC.VIOSD.IBM Director

考题 A manufacturing customer has an IBM BladeCenter H chassis with four, HX5 with MAX5 4-socket blades installed. Each blade has the optional Fibre Channel Expansion card. The customer wants redundancy and is going to install the following configuration:  (1)two Brocade 20-Port SAN Switch Modules  (2)two Nortel Networks 1/10 GB Uplink ESM  (3)a redundant AMM  What is the minimum number of power supplies needed for this configuration to have full redundancy?()A、4B、3C、2D、8

考题 A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A、4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server B、Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module C、Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module D、Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

考题 A customer needs to add three JS22 blade servers. The customer currently has three HS21 Blade servers and one LS41 4-socket Blade Server. Based upon this information,  what additional items does the customer need to purchase? ()A、An IBM BladeCenter H chassis for the JS22 Blade serversB、A concurrent KVM daughter cardC、A pair of IBM BladeCenter Power SuppliesD、A second Management Module

考题 An administrator wants to host several LPARs on a JS23 Blade server.  To achieve this what additional management software is required?()  A、HMCB、IVMC、VIOSD、IBM Director

考题 A customer wants to boot from an iSCSI SAN with their IBM BladeCenter infrastructure running Microsoft Windows Server 2000.  What is required for the customer to be able to perform this?()A、Fibre Channel Expansion Card for each Blade ServerB、cKVM Card for each Blade ServerC、iSCSI Expansion Card for each Blade ServerD、4Gb Modular Flash Drive

考题 A customer has purchased an IBM BladeCenter H chassis and needs the following servers:  --Two HS21 blade servers each with 8GB memory and 2 drives   --Two HS21 blade servers each with 24GB memory and 2 drives   --Two LS21 blade servers each with 2GB memory and 2 Hot-Swap SCSI drives   How many total server bays will be required for this configuration?()A、6B、8C、10D、12

考题 A Sales Specialist receives an email from a customer, requesting information on IBM’s best Server Consolidation solution. How should the Sales Specialist proceed? ()A、Send the customer information on VMwareB、Send the customer information on IBM BladeCenter C、Call the customer to ask why they are consolidatingD、Send the customer information on IBM System P

考题 A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()A、You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.B、Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.C、The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.D、The blade servers do not work with the Optical Pass-Thru Module.

考题 A media customer has an IBM BladeCenter E with ten HS22 Blade server installed. Currently only one Ethernet port is available for each server. What is required to enable the second port on eachserver?()A、Fiber Channel Switch ModuleB、Gb Ethernet expansion cardC、Myrinet Cluster expansion cardD、Ethernet Switch Module

考题 A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A、An HMC is required for dual VIO servers.B、Dual VIO servers require a split backplane.C、A dual VIO enablement code must be entered from the ASMI interface.D、The second VIO server must be created using the IVM command line interface.

考题 You need to design a strategy for identifying the number of instances that any one SQL Server 2005 computer will support. What should you do?()A、Specify that each server must have one instance for each customer.B、Specify that each server must each have only one instance.C、Specify that each server must have one instance for each database that is hosted on that server.D、Specify that each server must have one instance for each customer who has one or more databases that are hosted on that server.

考题 A medical customer has an installed HS21 blade with no local disk. They are attempting to set up boot from SAN using a Windows 2003 CD. Which sequence is correct for this procedure? ()A、Install Windows from the CD using the QLogic driver provided on the CD, configure the LUN and zone for the target server, and then configure the blade UEFI to boot from SAN.B、Configure the LUN and zone for the target server, install Windows from the CD and press F6 when prompted to supply the driver, and then configure the QLogic adapter BIOS to boot from SAN. C、Configure the LUN and zone for the target server, configure the QLogic adapter BIOS to boot from SAN, install Windows from the CD, and then press F6 when prompted to supply the driver. D、Configure the blade UEFI to boot from SAN, configure the LUN and zone for the target server, and then install Windows from the CD using the QLogic driver provided on the CD

考题 单选题A customer needs to add three JS22 blade servers. The customer currently has three HS21 Blade servers and one LS41 4-socket Blade Server. Based upon this information,  what additional items does the customer need to purchase? ()A An IBM BladeCenter H chassis for the JS22 Blade serversB A concurrent KVM daughter cardC A pair of IBM BladeCenter Power SuppliesD A second Management Module

考题 单选题You need to design a strategy for identifying the number of instances that any one SQL Server 2005 computer will support. What should you do?()A Specify that each server must have one instance for each customer.B Specify that each server must each have only one instance.C Specify that each server must have one instance for each database that is hosted on that server.D Specify that each server must have one instance for each customer who has one or more databases that are hosted on that server.

考题 单选题A blade server has been configured to boot from SAN.  After an HBA firmware upgrade the blade was rebooted and cannot find the operating system.  Which of the following should the administrator do NEXT to troubleshoot the issue?()A Verify all HBA settings.B Upgrade the blade firmware.C Upgrade the OS level HBA drivers.D Set the system to boot from the local disk.

考题 单选题A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

考题 单选题A media customer has an IBM BladeCenter E with ten HS22 Blade server installed. Currently only one Ethernet port is available for each server. What is required to enable the second port on eachserver?()A Fiber Channel Switch ModuleB Gb Ethernet expansion cardC Myrinet Cluster expansion cardD Ethernet Switch Module

考题 单选题A customer has purchased an IBM BladeCenter H chassis and needs the following servers:  --Two HS21 blade servers each with 8GB memory and 2 drives   --Two HS21 blade servers each with 24GB memory and 2 drives   --Two LS21 blade servers each with 2GB memory and 2 Hot-Swap SCSI drives   How many total server bays will be required for this configuration?()A 6B 8C 10D 12

考题 单选题A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A 4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server B Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module C Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module D Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

考题 单选题You need to design a hosting service option for customers who want to access their databases by using their own Active Directory domain accounts. What should you do?()A Design a hosting service option that duplicates each customer’s domain user account as SQL Serverlogin account.B Design a hosting service option that provides VPN-based connectivity from each customer’s network tothe SQL Server computer that hosts that customer’s daabase or databases.C Design a hosting service option that provides a dedicated server to each customer.Join that server to that customer’s Active Directory domainD Design a hosting service option that configures a unique instance of SQL Server 2005 for each customer.Configure that instance to use Integrated Windows authentication.

考题 单选题A Sales Specialist receives an email from a customer, requesting information on IBM’s best Server Consolidation solution. How should the Sales Specialist proceed? ()A Send the customer information on VMwareB Send the customer information on IBM BladeCenter C Call the customer to ask why they are consolidatingD Send the customer information on IBM System P

考题 单选题A medical customer has an installed HS21 blade with no local disk. They are attempting to set up boot from SAN using a Windows 2003 CD. Which sequence is correct for this procedure? ()A Install Windows from the CD using the QLogic driver provided on the CD, configure the LUN and zone for the target server, and then configure the blade UEFI to boot from SAN.B Configure the LUN and zone for the target server, install Windows from the CD and press F6 when prompted to supply the driver, and then configure the QLogic adapter BIOS to boot from SAN. C Configure the LUN and zone for the target server, configure the QLogic adapter BIOS to boot from SAN, install Windows from the CD, and then press F6 when prompted to supply the driver. D Configure the blade UEFI to boot from SAN, configure the LUN and zone for the target server, and then install Windows from the CD using the QLogic driver provided on the CD

考题 单选题An administrator wants to host several LPARs on a JS23 Blade server. To achieve this, what additional management software is required?()A HMCB IVMC VIOSD IBM Director

考题 单选题A manufacturing customer has an IBM BladeCenter H chassis with four, HX5 with MAX5 4-socket blades installed. Each blade has the optional Fibre Channel Expansion card. The customer wants redundancy and is going to install the following configuration:  (1)two Brocade 20-Port SAN Switch Modules  (2)two Nortel Networks 1/10 GB Uplink ESM  (3)a redundant AMM  What is the minimum number of power supplies needed for this configuration to have full redundancy?()A 4B 3C 2D 8

考题 单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()A You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.B Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.C The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.D The blade servers do not work with the Optical Pass-Thru Module.

考题 单选题A customer wants to boot from an iSCSI SAN with their IBM BladeCenter infrastructure running Microsoft Windows Server 2000.  What is required for the customer to be able to perform this?()A Fibre Channel Expansion Card for each Blade ServerB cKVM Card for each Blade ServerC iSCSI Expansion Card for each Blade ServerD 4Gb Modular Flash Drive

考题 单选题A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A An HMC is required for dual VIO servers.B Dual VIO servers require a split backplane.C A dual VIO enablement code must be entered from the ASMI interface.D The second VIO server must be created using the IVM command line interface.