网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The() is a smaller valve fitted in the auxiliary steam supply line, and is usually of the non-return type.
A

main stem stop valve

B

auxiliary steam stop valve

C

feed check or control valve

D

blow down valve


参考答案

参考解析
解析: 暂无解析
更多 “单选题The() is a smaller valve fitted in the auxiliary steam supply line, and is usually of the non-return type.A main stem stop valveB auxiliary steam stop valveC feed check or control valveD blow down valve” 相关考题
考题 The deck control valve to be ______ after being repaired.A.returned and attached againB.moved and fitted againC.removed and refittedD.reproduced and put on again

考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

考题 A device fitted over the discharge opening on a relief valve consisting of one or two woven wire fabrics is called a flame ______.A.stopperB.screenC.filterD.restrictor

考题 Valves on steam-smothering lines to cargo tanks shall be set with ______.A.The master control valve shut and valves to individual cargo tanks shutB.The master control valve open and valves to individual cargo tanks shutC.The master control valve shut and valves to individual cargo tanks openD.All valves open

考题 If the hatch cover does not move, ()should be checked.A、the open valveB、the stop valveC、the steam valveD、the close valve

考题 单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()A cold fuel oilB low fuel oil pressureC low atomizing steam pressureD water in the fuel oil

考题 单选题A device fitted over the discharge opening on a relief valve consisting of one or two woven wire fabrics is called a().A flame stopperB flame screenC flame filterD flame restrictor

考题 单选题The deck control valve to be()after being repaired.A moved and fitted againB removed and refittedC reproduced and put on againD returned and attached again

考题 单选题The() is fitted in pair one is the main valve, the other the auxiliary or standby.A main stem stop valveB auxiliary steam stop valveC feed check or control valveD blow down valve

考题 单选题A gypsy or gypsyhead is a().A punt used for painting over the sideB small, reciprocating steam engineC spool-shaped drum fitted on a winchD swinging derrick

考题 单选题Between the steam dram and the smaller water dram below, large numbers of smaller diameter () tubes are fitted.A fireB water wallC generatingD down comer

考题 单选题If the hatch cover does not move, ()should be checked.A the open valveB the stop valveC the steam valveD the close valve

考题 单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().A steam stop valveB dry pipeC feedwater systemD generating tubes

考题 单选题To assist separation of low viscosity oils steam coils or electric heaters are fitted () of the oily water separator.A in entranceB in exitC in the upper partD on the outside

考题 单选题Fire protection regulations for towing vessels require any fuel line subject to internal head pressure from fuel in the tank to().A be fitted with a positive fuel shut-off valve located at the tankB have a shut-off valve at the top of the tankC have a gate valve easily accessible in the space where the tank is locatedD have a drain cock at the lowest point in the fuel line

考题 单选题Large pipes or () are fitted between the steam and water drums to ensure good natural circulation of water.A fire-tubesB furnacesC down-comersD soot-blowers

考题 单选题The()is fitted in the main steam supply line and is usually of the non-return type.A main steam stop valveB auxiliary steam stop valveC feed check or control valveD blow down valve

考题 单选题Excessive valve lash in an auxiliary diesel engine will cause the valves to open()A later and close soonerB sooner and close laterC sooner and close soonerD later and close later

考题 单选题The() is a smaller valve fitted in the auxiliary steam supply line, and is usually of the non-return type.A main stem stop valveB auxiliary steam stop valveC feed check or control valveD blow down valve

考题 单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A air supply is shut offB fuel supply is shut offC water supply is shut offD safety valve lifts

考题 单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A monkeyB donkeyC waste heatD main

考题 单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A carbon deposits on the flame scannerB high fuel oil temperatureC low fuel oil viscosityD high steam pressure

考题 单选题A feed pump for an auxiliary boiler might lose suction if the ().A boiler water level is lowB feedwater is too hotC boiler steam demand is lowD feedwater is too cold

考题 单选题The water level in a steaming auxiliary boiler will always ()A rise when the steam pressure is increasedB remain constant as long as the feed pump operatesC fall when the steam pressure is decreasedD vary as the steam demand changes

考题 单选题A butterfly valve consists basically of a disc pivoted across the bore of a ring body having the same radial dimensions as the pipe in which it is fitted.According to the above sentence, which of the following statements is not true?()A The diameter of a disc is the same as the outer diameter of the pipeB We can infer that the valve is opened or closed by rotating the spindleC A butterfly valve comprises a disc and a ring bodyD The profile of the butterfly valve is a ring body

考题 单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A check and regulate the water levelB close the air cock once fires are litC blowdown the gage glassD crack the steam stop to assure protective steam flow

考题 单选题A device fitted over the discharge opening on a relief valve consisting of one or two woven wire fabrics is called a flame().A stopperB screenC filterD restrictor