网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

A large shipping company that is standardized on Fibre Channel storage has just acquired a regional shipping company that is using an IBM XIV system. The large company would like to integrate the XIV system into the environment and manage all data through a single management interface.Which product should be suggested so that all data can be managed?()

A. IBM DS8700

B. IBM XIV GUI

C. IBM System Storage N7600

D. IBM SAN Volume Controller (SVC)


参考答案

更多 “ A large shipping company that is standardized on Fibre Channel storage has just acquired a regional shipping company that is using an IBM XIV system. The large company would like to integrate the XIV system into the environment and manage all data through a single management interface.Which product should be suggested so that all data can be managed?()A. IBM DS8700B. IBM XIV GUIC. IBM System Storage N7600D. IBM SAN Volume Controller (SVC) ” 相关考题
考题 An administrator wants to have the flexibility to dynamically move a fibre channel PCI card between given LPARs.For each given LPAR how should they add the PCI card to the LPAR profile?() A.Add the fibre channel card as hared?Add the fibre channel card as ?hared?B.Add the fibre channel card as irtual?Add the fibre channel card as ?irtual?C.Add the fibre channel card as esired?Add the fibre channel card as ?esired?D.Add the fibre channel card as equired?Add the fibre channel card as ?equired?

考题 A customer has installed an IBM System Storage DS8700 with 20 TB of storage, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues since they have added new workloads. The customer asks the storage specialist for guidance.Which of the following actions should be recommended as a first step?()A. install the Performance Accelerator featureB. review the DS Storage Manager Major Event Log (MEL)C. add an expansion frame with additionalFibre Channel portsD. review the latest TPC for Disk study to identify the source of the performance issue

考题 Which IBM tape interface architecture has the best performance and distance characteristics? () A.SASB.SCSIC.ESCOND.Fibre Channel

考题 Fibre Channel, or FC, is a gigabit-speed network technology primarily used for storage networking.Fibre Channel is standardized in the T11 Technical Committee of the InterNational Committee for Information Technology Standards (INCITS), an American National Standards Institute (ANSI) Caccredited standards committee.Which two of these correctly describe Fibre Channel?()A. supports multiple protocolsB. works only in a shared or loop environmentC. allows addressing for up to 4 million nodesD. provides a high speed transport for SCSI payloads

考题 In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches

考题 A Fibre Channel fabric (or Fibre Channel switched fabric, FC-SW) is a switched fabric of FibreChannel devices enabled by a Fibre Channel switch. Fabrics are normally subdivided by Fibre Channel zoning. Each fabric has a name server and provides other services. Higher redundancy over FC-AL,P2P.Which path selection protocol is used by Fibre Channel fabrics?()A、 OSPFB、 RIPC、 FSPFD、 VSANs

考题 A Fibre Channel fabric (or Fibre Channel switched fabric, FC-SW) is a switched fabric of Fibre Channel devices enabled by a Fibre Channel switch. Fabrics are normally subdivided by Fibre Channel zoning.Each fabric has a name server and provides other services. Higher redundancy over FC-AL, P2P.Which path selection protocol is used by Fibre Channel fabrics?()A、OSPFB、RIPC、FSPFD、VSANs

考题 Which of the following describes the advantage of using Fibre Channel over Ethernet (FCoE) in POWER6 and POWER7 Blades?()A、The FCoE card provides both LAN and fibre channel function from a single card on the blade. B、The FCoE advanced technology removes the need for any BladeCenter switching to support this function.C、Component reliability on the fibre channel over Ethernet is higher than on regular Ethernet and fibre channel adapters.D、The AIX device driver for FCoE has been completely rewritten for the current adapter, eliminating errors and performance issues.

考题 Which interconnect is used on the storage side of the SONAS storage node to provide highperformance?()A、6 Gbps SAS B、Fibre Channel C、10 Gb Ethernet D、InfiniBand (IB)

考题 A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()A、Would 10/100 Ethernets work as well?B、Should there be eight fibre channel adapters?C、Should there be an async adapter for heartbeat?D、Will all LPARs need access to a common fibre channel tape drive?

考题 A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()A、LPAR-A with 1Gb FC HBA and SAN connectionB、LPAR-B with 2Gb FC HBA and SAN connectionC、LPAR-C with 4Gb FC HBA and SAN connectionD、LPAR-D with 8Gb FC HBA and SAN connection

考题 A customer has installed an IBM System Storage DS8700 with 20 TB of storage, two-way processor version, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues.  To address this performance consideration with minimal cost to the customer, which of the following should be the FIRST step to resolve the problem()A、add an expansion frame with additionalFibre Channel portsB、increase the amount of storage by 20 TBC、conduct a Disk Magic study to identify the source of the performance issueD、add additionalFibre Channel ports to the existing DS8700

考题 What types of host connectivity are available on the Storwize V7000?()A、Fibre Channel and SAS B、Fibre Channel and iSCSI C、Fibre Channel, iSCSI and SAS D、Fibre Channel, iSCSI and InfiniBand 

考题 Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()  A、 Disk heartbeatB、 Error notificationC、 Event notificationD、 Application monitor

考题 Company.com has a non-IBM disk storage unit connected by two Fibre channel connections. The  Nodes have multiple connections to the storage device that allow load balancing. A failure with one Fibre adapter or connection will not be noticed by the application, but it needs to be addressed.  How can HACMP help make this environment more robust?()  A、 Customize disk heartbeat methods to detect disk adapter failures.B、 Customize an error notification method that monitors for volume group quorum loss.C、 Customize an error notification facility to act on the event when reported to the error log.D、 Customize a HACMP event script to monitor the disk connections and cause a fallover if there is a failure.

考题 A company runs very large database applications on multiple HP-UX servers. They recently upgraded the device drivers for their fibre channel HBAs and have suffered numerous crashes on several systems. Which feature of Power Systems running AIX would help eliminate this problem during pre-release testing of a new device driver?()A、Redundant VIO serversB、Storage Protection KeysC、Electronic Service AgentD、NPIV support in the kernel

考题 A large shipping company that is standardized on Fibre Channel storage has just acquired a regional shipping company that is using an IBM XIV system. The large company would like to integrate the XIV system into the environment and manage all data through a single management interface. Which product should be suggested so that all data can be managed?()A、IBM DS8700B、IBM XIV GUIC、IBM System Storage N7600D、IBM SAN Volume Controller (SVC)

考题 A customer has installed an IBM System Storage DS8700 with 20 TB of storage, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues since they have added new workloads. The customer asks the storage specialist for guidance. Which of the following actions should be recommended as a first step?()A、install the Performance Accelerator featureB、review the DS Storage Manager Major Event Log (MEL)C、add an expansion frame with additionalFibre Channel portsD、review the latest TPC for Disk study to identify the source of the performance issue

考题 An administrator wants to have the flexibility to dynamically move a fibre channel PCI card between given LPARs. For each given LPAR how should they add the PCI card to the LPAR profile?()A、Add the fibre channel card as hared?Add the fibre channel card as ?hared?B、Add the fibre channel card as irtual?Add the fibre channel card as ?irtual?C、Add the fibre channel card as esired?Add the fibre channel card as ?esired?D、Add the fibre channel card as equired?Add the fibre channel card as ?equired?

考题 Which IBM tape interface architecture has the best performance and distance characteristics? ()A、SASB、SCSIC、ESCOND、Fibre Channel

考题 A manufacturing company has a large facility which has its offices at one end and a manufacturing floor at the other.  The company is looking to implement new equipment that requires access to the company’s SAN that is over 2.4 kilometers away in the office area. Which of the following solutions will satisfy this requirement?()A、Install a longwave GBIC in the office SAN switch and string a multimode fibre from the office to the manufacturing floorB、Install a longwave GBIC in the office SAN switch and string a singlemode fibre from the office to the manufacturing floorC、Install a shortwave GBIC in the office SAN switch and string a multimode fibre from the office to the manufacturing floorD、Install a shortwave GBIC in the office SAN switch and string a singlemode fibre from the office to the manufacturing floor

考题 单选题A Fibre Channel fabric (or Fibre Channel switched fabric, FC-SW) is a switched fabric of FibreChannel devices enabled by a Fibre Channel switch. Fabrics are normally subdivided by Fibre Channel zoning. Each fabric has a name server and provides other services. Higher redundancy over FC-AL,P2P.Which path selection protocol is used by Fibre Channel fabrics?()A  OSPFB  RIPC  FSPFD  VSANs

考题 单选题A virtual storage area network (VSAN) is a collection of ports from a set of connected Fibre Channel switches, that form a virtual fabric. Which technology allows centralized storage services to be shared across different VSANs?()A IVRB FSPFC FICOND SANTap

考题 单选题A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A One fibre channel switchB Two fibre channel switchesC Two Ethernet cardsD Nothing

考题 单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A  Only to Cisco Fibre Channel switchesB  Only to Cisco Fibre Channel switches in NPIV modeC  To any Fibre Channel switchD  Directly to storage arraysE  Only to Nexus Switches

考题 单选题Company.com has non-IBM fibre attached storage. The storage is connected to a node in the  cluster that has multiple adapters and virtual paths. There is a concern about detecting the loss of one of the fibre adapters since there is no indication to the administrator that one has failed.  What feature of HACMP can be sued to assist with this issue?()A  Disk heartbeatB  Error notificationC  Event notificationD  Application monitor

考题 多选题Fibre Channel, or FC, is a gigabit-speed network technology primarily used for storage networking.Fibre Channel is standardized in the T11 Technical Committee of the InterNational Committee for Information Technology Standards (INCITS), an American National Standards Institute (ANSI) Caccredited standards committee.Which two of these correctly describe Fibre Channel?()Asupports multiple protocolsBworks only in a shared or loop environmentCallows addressing for up to 4 million nodesDprovides a high speed transport for SCSI payloads