网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
C3I system for Air Defense 即为防空C3I系统,下列哪一项不是其中之一:()
- A、指挥
- B、控制
- C、通信
- D、侦察
参考答案
更多 “C3I system for Air Defense 即为防空C3I系统,下列哪一项不是其中之一:()A、指挥B、控制C、通信D、侦察” 相关考题
考题
What is the function of the after-coolers installed in the diesel engine air intake system?A.Decrease the air densityB.Increase the exhaust temperatureC.Decrease the lube oil temperatureD.Increase the air density
考题
第二组Under normal operation, some lubrication oil mist may be discharged from the air compressor to the air start system. This oil may be from excess compressor cylinder lubrication, from faulty oil scraper rings, or may even be suspended oil vapor contaminating the engine room atmosphere and drawn in at the compressor suction. Oil discharge is kept to a minimum by draining the after cooler, air receiver and starting system. If small quantities of lubrication oil do get passed into the starting air system, they will deposit as thin moist film over internal pipe surfaces but are not readily combustible. If a cylinder non-return valve leak while the engine is in operation, some hot gas, possibly with unburned fuel and cylinder lubrication oil, may be blown through the valve to the adjacent air manifold. With further heating from the leaky valve, this, together with the already deposited oil film, will carbonize and form. incandescent carbon. If starting air is applied to the system while still hot, the high pressure air coming into contact with the burning carbon may cause an explosion. Such an explosion will cause a flame to pass back through the air start pipe system, evaporating the deposited oil film and igniting it in the presence of air. Very high velocities and shockwaves are generated which may rupture pipes and fittings.Alternatively, if excessive oil has entered the air start system, a mixture of air and oil droplets may be discharged through the open cylinder non-return valve during starting. This spray may ignite due to high temperatures in the cylinder, causing a flame through the still open valve to the air manifold.To prevent an explosion, air start valves must be correctly maintained and lubricated to ensure correct timing and free movement with positive closing. Oil in the system must be kept to a minimum, pipe lines must be drained and cleaned internally when necessary and oil discharge from air compressors must be kept to a minimum by good maintenance.The passage is mainly aboutA.crankcase explosionB.scavenge box fireC.starting air pipeD.the danger of explosion in the starting air system
考题
Air cocks, usually positioned at the_______in a circulating system, is used to get rid of the air in the system.A.bending jointB.expansion tankC.weldD.the highest point
考题
Restrictions occurring in the small orifices(孔) of pneumatic control system components can be caused by ______.A.moisture in the compressed air supplyB.excessive dryness in the compressed air supplyC.pressure surging in the compressed air receiverD.insufficient lubrication of the system components
考题
In an air conditioning system, moisture is removed from the air by ______.A.filtersB.separatorsC.ducted trapsD.dehumidifiers
考题
The“three arms of government” of Australia refers to the Parliament,the Executive Government and( ) A.the Judiciary
B.the High Court
C.the Defense Force
D.the Air Force
考题
单选题Air blowing from the intake air filter of an operating air compressor indicates ().A
broken inlet valvesB
broken discharge valvesC
pulsations in the air distribution systemD
overloading of the air distribution system
考题
单选题What is the function of an air receiver in the compressed air system on a ship? ()A
Condenses moistureB
Provides overpressure protectionC
Purifies the airD
Acts as an accumulator
考题
单选题In an air conditioning system, moisture is removed from the air by()A
filersB
separatorsC
ducted trapsD
dehumidifiers
考题
单选题A re-heater in an air conditioning system functions to ().A
control inlet air temperatureB
control inlet air volumeC
maintain relative humidity at 15%D
restore conditioned air temperature to a comfortable level
考题
单选题For the proper control of the air temperature in an air conditioning system using chilled water circulation, which of the listed conditions should remain constant regardless of load changes?()A
Chilled water system supply temperatureB
Chilled water system return temperatureC
Compressor discharge temperatureD
Compressor suction pressure
考题
单选题Restrictions occurring in the small orifices of pneumatic control system components can be used by ()A
moisture in the compressed air supplyB
excessive dryness in the compressed air supplyC
pressure surging in the compressed air receiverD
insufficient lubrication of the system components
考题
单选题Air cocks, usually positioned at the () in a circulating system, is used to get rid of the air in the system.A
bending jointB
expansion tankC
weldD
the highest point
考题
单选题Diesel engine air start system check valves are opened by ()A
an air start camB
cylinder compression pressureC
starting air pressureD
valve springs
考题
单选题In the starting system, the automatic valve is controlled by(), and the cylinder start valves are controlled by()A
pilot air;pilot airB
handle;solenoidC
handle;pilot air coming through the distributorD
solenoid;pilot air coming through the distributor
考题
单选题The primary task of the compressed air system is to deliver the starting air necessary for ()A
starting the MEB
starting the emergency electric alternatorC
driving the main turbineD
driving the turbocharger
考题
判断题To keep the prosperity of the air industry, the Department of Defense has invested a lot of money to develop an innovative type of aircraft which does not need a runway.A
对B
错
考题
单选题If an air compressor is used to supply compressed air to outlets throughout the engine room and on deck of a vessel, the system is known as the ().A
combustion control air systemB
supply air systemC
ships service air systemD
low pressure deck air system
考题
单选题Which of the following methods is normally used to control the temperature of air distributed from individual cooling coils in an air conditioning system using a chilled water circulation system?()A
A room thermostat activates an electric heater at each individual chilled air outlet when necessaryB
Varying the number of passes the air makes across the coilsC
Varying the temperature of the water through the coilsD
Varying the quantity of water flowing through the coils
考题
单选题To prevent the unnecessary loading of an air conditioning system while maintaining the designed dry bulb temperature and relative humidity in an air conditioning system, you should ()A
admit only enough fresh outside air to provide proper ventilationB
reduce the air reheating system loadC
lower the compressor head pressureD
operate the purge recovery unit continuously
考题
单选题As a defense against air-pollution damage, many plants and animals _____ a substance to absorb harmful chemicals.A
relieveB
releaseC
dismissD
discard
考题
单选题Pump up the starting air reservoirs to their maximum pressure and ()the air reservoirs and air system.A
openB
closeC
drainD
vent
考题
单选题If an air compressor is used to supply air primarily to the combustion control system and other pneumatic controllers, the entire system is known as the ().A
control air systemB
forced draft air systemC
supply air systemD
ships service air system
考题
单选题What is the function of the after-cooler installed in the diesel engine air intakes system?()A
Decrease the air densityB
Increase the exhaust temperatureC
Decrease the lube oil temperatureD
Increase the air density
热门标签
最新试卷