When two AC generators are being paralleled, the breaker should be closed with the synchroscope pointer mating in the ()
A

slow direction, just before the 12 o'clock position

B

fast direction, just after the 12 o'clock position

C

fast direction, just before the 12 o'clock position

D

slow direction, just after the 12 o'clock position


参考答案

参考解析
解析: 暂无解析
更多 “单选题When two AC generators are being paralleled, the breaker should be closed with the synchroscope pointer mating in the ()A slow direction, just before the 12 o'clock positionB fast direction, just after the 12 o'clock positionC fast direction, just before the 12 o'clock positionD slow direction, just after the 12 o'clock position” 相关考题
考题 ( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators

考题 You are attempting to parallel two AC.generators, and the synchroscope pointer revolving in the fast direction.This indicates that the frequency of the incoming machine is A.higher than the bus equencyB.lower than the bus equencyC.the same as the bus frequency but out of phase with itD.same as the bus frequency and the circuit breaker may be closed at

考题 When the prime movers of two paralleled generators are equipped with mechanical-hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will .A.pick up more of any increase in loadB.pick up less of any increase in loadC.share an equal amount of any increase in loadD.drop an equal amount of any decrease in load

考题 An alternator is being paralleled with one on the line At the instant the circuit breaker is close, the frequency of the incoming alternator will normallyA.increaseB.not changeC.decreaseD.be exactly 60 hertz

考题 You are attempting to parallel two AC generators and the synchroscope pointer is revolving in the slow direction. This indicates that the frequency of the incoming machine isA.higher than the bus frequencyB.lower than the bus frequencyC.file same as file bus frequency but out of phase with itD.the same as the bus frequency, and the circuit breaker may be closed at nay pointer position

考题 Equal power factors on paralleled AC generators are maintained by an automatic ________.A.governor control switchB.reverse power relayC.reverse current relayD.voltage regulator

考题 While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.A.running at the same speedB.groundedC.of the same polarityD.in phase

考题 In which two conditions are resumable statements suspended?()A、 when a user exceeds the space quotaB、 when a user session is terminatedC、 when a table that is being accessed by the current transaction is not foundD、 when a user manually suspends the statementE、 when the maximum extents of a segment is reached

考题 Which of the following multimeter settings should only be used when there is no electrical flow through the part being tested? ()(Select TWO).A、AmpereB、ContinuityC、VoltD、ResistanceE、Wattage

考题 单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().A voltage regulatorsB field rheostatsC reverse power relaysD prime mover governors

考题 单选题Which is a function of the voltage regulators used with AC generators?()A To cut out generators when they are no longer requiredB To cut in additional generators automatically as requiredC To divide the KW load equally between generators operating in parallelD To divide reactive current between generators operating in parallel

考题 单选题A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()A an electrical interlock systemB an automatic paralleling trip switchC the synchronizing oscilloscopeD the reverse current relay

考题 单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().A running at the same speedB groundedC of the same polarityD in phase

考题 单选题An alternator switchboard has a synchroscope and synchronizing lamps, if the synchroscope is broken, which of the steps listed is the most essential before an alternator can be paralleled with the bus ()A The breaker should be closed when one synchronizing lamp is dark and the other is brightB The breaker should be closed when both synchronizing lamps are brightC The frequency meter should be used to determine that the incoming alternator frequency is slightly higher than the busD A portable phase sequence indicator must be used to verify the information from the lamps

考题 单选题When the prime movers of two paralleled generators are equipped with mechanical- hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will ().A pick up more of any increase in loadB pick up less of any increase in loadC share an equal amount of any increase in loadD drop an equal amount of any decrease in load

考题 单选题Equal power factors on paralleled AC generators are maintained by an automatic ().A voltage regulatorB reverse power relayC reverse current relayD governor control switch

考题 单选题Why is it desirable to operate paralleled AC generators at the same power factor?()A Circulating currents are kept to a minimumB Field excitation losses are kept to a minimumC Generator rotors will have a lesser tendency to huntD Because a power factor increase will decrease kilowatt output

考题 多选题Which of the following multimeter settings should only be used when there is no electrical flow through the part being tested? ()(Select TWO).AAmpereBContinuityCVoltDResistanceEWattage

考题 单选题Which of the listed governor characteristics will greatly affect the load sharing relationship between paralleled diesel generators?()A SensitivityB PowerC Speed droopD Compensation

考题 单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()A an incorrect diesel generator governor speed droop adjustmentB a faulty reverse power relay within the main circuit breaker assemblyC unsynchronized isochronous load distribution adjustmentsD a different speed setting on each unit

考题 单选题When paralleled, AC generators must have the same ()A frequencyB number of phasesC phase rotationD All of the above

考题 单选题When two DC generators operate in parallel, they are protected against motorizing by()A blow out coilsB governor relayC under voltage tripsD reverse current trips

考题 单选题If two AC generators are to be operated in parallel, the load is distributed evenly by()A means of rheostat the governor settingsB a balance coil excitationC adjusting the governor settingsD changing excitation

考题 单选题You are attempting to parallel two AC generators, and the syncope pointer is revolving in the fast directionThis indicates that the frequency of the incoming machine is ().A higher than the bus frequencyB lower than the bus frequencyC the same as the bus frequency but out of phase with itD the same as the bus frequency and the circuit breaker may be closed at any pointer position

考题 单选题If two AC generators are operated in parallel, the load is distributed evenly by()A a rheostatB a balancing coilC changing field excitationD adjusting the governor settings

考题 单选题Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine ()A slightly less than the line frequencyB the same as the line frequencyC slightly greater than the line frequencyD All of the above

考题 单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()A slightly less than the oncoming generator frequencyB the same as the bus frequencyC slightly greater than the bus frequencyD the same as the bus voltage