The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().
A

voltage regulators

B

field rheostats

C

reverse power relays

D

prime mover governors


参考答案

参考解析
解析: 暂无解析
更多 “单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().A voltage regulatorsB field rheostatsC reverse power relaysD prime mover governors” 相关考题
考题 ( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators

考题 When the prime movers of two paralleled generators are equipped with mechanical-hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will .A.pick up more of any increase in loadB.pick up less of any increase in loadC.share an equal amount of any increase in loadD.drop an equal amount of any decrease in load

考题 The division of kilowatt load between two paralleled alternators is determined by theA.amount of field excitation of the leading machineB.load-speed characteristics of the governorsC.amount of field excitation to the lagging machineD.type of alternator

考题 While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.A.running at the same speedB.groundedC.of the same polarityD.in phase

考题 The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.A.load limit settingsB.idle speed settingsC.speed limit settingsD.speed droop settings

考题 Which three statements about anycast RP are true? ()A、MSDP is running between anycast RPsB、Anycast RP provides redundancy and load-sharing capabilitiesC、Multicast BGP is running between anycast RPsD、In anycast RP,two or more RPs are configured with the same multicast IP address on loopback interfacesE、In anycast RP,two or more RPs are configured with the same unicast IP address on loopback interfaces

考题 When load balancing traffic between two web servers, which of the following technologies provides the LOWEST cost solution?()A、 Active/passive clusterB、 Active/active clusterC、 Log shippingD、 DNS round robin

考题 Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()A、MulticastB、Active/passive clusterC、Active/active clusterD、DNS round robin

考题 单选题Which is a function of the voltage regulators used with AC generators?()A To cut out generators when they are no longer requiredB To cut in additional generators automatically as requiredC To divide the KW load equally between generators operating in parallelD To divide reactive current between generators operating in parallel

考题 单选题Generators should have an excitation/voltage regulation system which will enable them to share the steady state reactive load () no machine exceeds its proportional share of reactive load by more than 10% of the rated reactive load of the largest generator.A whenB so asC such thatD though

考题 单选题What letter is two to the right of the letter immediately to the left of the letter that comes mid-way between the letter immediately to the left of the letter H and the letter two to the right of the letter A?A C.B D.C E.D F.

考题 单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().A running at the same speedB groundedC of the same polarityD in phase

考题 单选题When the prime movers of two paralleled generators are equipped with mechanical- hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will ().A pick up more of any increase in loadB pick up less of any increase in loadC share an equal amount of any increase in loadD drop an equal amount of any decrease in load

考题 单选题Why is it desirable to operate paralleled AC generators at the same power factor?()A Circulating currents are kept to a minimumB Field excitation losses are kept to a minimumC Generator rotors will have a lesser tendency to huntD Because a power factor increase will decrease kilowatt output

考题 单选题Which of the listed governor characteristics will greatly affect the load sharing relationship between paralleled diesel generators?()A SensitivityB PowerC Speed droopD Compensation

考题 单选题When load balancing traffic between two web servers, which of the following technologies provides the LOWEST cost solution?()A  Active/passive clusterB  Active/active clusterC  Log shippingD  DNS round robin

考题 多选题What are two functions that the parameter max-session performs? ()(Choose two.)ADefines the session limit for the domain.BDefines the session limit for the tunnel instance.CUsed to control load balancing between multiple domains.DUsed to control load balancing between multiple tunnels for a domain.

考题 单选题If two AC generators are to be operated in parallel, the load is distributed evenly by()A means of rheostat the governor settingsB a balance coil excitationC adjusting the governor settingsD changing excitation

考题 单选题You are attempting to parallel two AC generators, and the syncope pointer is revolving in the fast directionThis indicates that the frequency of the incoming machine is ().A higher than the bus frequencyB lower than the bus frequencyC the same as the bus frequency but out of phase with itD the same as the bus frequency and the circuit breaker may be closed at any pointer position

考题 单选题If two AC generators are operated in parallel, the load is distributed evenly by()A a rheostatB a balancing coilC changing field excitationD adjusting the governor settings

考题 单选题You have two EBGP peers connected via two parallel serial lines. What should you do to be able to load-balance between two EBGP speakers over the parallel serial lines in both directions? ()A nothing,BGP automatically load-balances the traffic between different autonomous systems on all available linksB peer between the eBGP speaker’s loopbacks, configuring eBGP multihop as required, and use an IGP to load-share between the two equal-cost paths between the loopback addressesC configure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the EBGP peer loopback address;it is also necessary to use the next-hop-self commandD use the ebgp-load-balance command on the neighbor statement on both sidesE configure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the peer loopback address;it is also necessary to use the ebgp-multihop and next-hop-self commands

考题 单选题AC and DC generators are similar in that they ()A both generate alternating voltagesB both rectify the voltage before deliveryC are constructed at the same physical size for the same kilowatt ratingD both supply three-phase power

考题 单选题Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()A  MulticastB  Active/passive clusterC  Active/active clusterD  DNS round robin

考题 单选题If two A.C.generators are to be operated in parallel, the load is distributed evenly by()A means of rheostat the governor settingsB a balance coil excitationC adjusting the governor settingsD changing excitation

考题 单选题Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine ()A slightly less than the line frequencyB the same as the line frequencyC slightly greater than the line frequencyD All of the above

考题 单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()A slightly less than the oncoming generator frequencyB the same as the bus frequencyC slightly greater than the bus frequencyD the same as the bus voltage

考题 单选题The division of kilowatt load between two paralleled alternators is determined by the ()A amount of field excitation of the leading machineB load-speed characteristics of the governorsC amount of field excitation to the lagging machineD type of alternator