A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()
A

Dual power supplies.

B

Twice the amount of disk.

C

Two dual-port LHEA adapters.

D

Two dual-port fibre channel adapters.


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A Dual power supplies.B Twice the amount of disk.C Two dual-port LHEA adapters.D Two dual-port fibre channel adapters.” 相关考题
考题 A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system.Which would be the most critical option to mitigate AIX availability?()A.Dual power supplies.B.Twice the amount of disk.C.Two dual-port LHEA adapters.D.Two dual-port fibre channel adapters.

考题 Your customer wants to build a network for a financial trading floor that has a requirement for multiple high-value transactions, which are also vital to the customer. What are the two most critical requirements? ()(Choose two.)A. no single point of failureB. trading database server locationC. redundant application servers locationD. deterministic response to all failuresE. determine which protocol to use

考题 A customer has a mixed environment of AIX on POWER4 and POWER5, and x86 based systems running a supported distribution of Linux. There is a total of 7 partitions and three standalone x86 servers. The customer wants to consolidate their applications using a single 4-core POWER6 server.  What is the minimum PowerVM edition that supports the customer requirement?()A、 PowerVM Lx86B、 PowerVM Express EditionC、 PowerVM Standard EditionD、 PowerVM Enterprise Edition

考题 During consultation, you find that a customer has only a single asset closet and is looking for asolution that is easy to deploy. Which NAS physical deployment model would you suggest to this customer?()A、 edgeB、 centralC、 Layer 2D、 Layer 3

考题 Your customer wants to build a network for a financial trading floor that has a requirement for multiple high-value transactions, which are also vital to the customer. What are the two most critical requirements? ()(Choose two.)A、no single point of failureB、trading database server locationC、redundant application servers locationD、deterministic response to all failuresE、determine which protocol to use

考题 A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()A、Etherchannel and trunkingB、Network Interface Backup and EtherchannelC、Shared Ethernet Adapter (SEA) Failover and EtherchannelD、Network Interface Backup and Shared Ethernet Adapter failover

考题 Companycom has just purchased a p5 570 with AIX 5.3. The customer would like to add a training LPAR to the system, but no processors are available. All of the partitions are using dedicated resources. The test LPAR is using one processor and has a 90% CPU idle rate. What can be done to setup this training LPAR quickly without disabling their current environment?()A、Use AIX 5.3 which supports micro-partitioning for both the test and training LPARSB、Use DLPAR to move resources from the test LPAR to training when training is activeC、Install Partition Load Manager to share resources between the test and training environmentsD、Install Advanced Power Virtualization and then use micro-partitioning for both the test and training LPARs

考题 During consultation, you find that a customer has only a single asset closet and is looking for a solution that is easy to deploy. Which NAS physical deployment model would you suggest to this customer?()A、edgeB、centralC、Layer2D、Layer3

考题 A customer has purchased a triple channel memory kit containing three DDR3 RAM modules. Theserver the RAM is intended for only has a dual channel capable motherboard. Which of the following is the BEST action to perform?()A、Install only two modules as the RAM has to be installed in pairsB、Purchase one additional RAM module to make it even. Three modules will function as triplechannel and the additional module will be for parityC、Purchase dual channel memory. The triple channel memory may be incompatible with theserver motherboardD、Install the RAM.Two modules will perform as dual channel and one as single channel

考题 A customer has a Power 770 running an SAP ERP workload on AIX 7. It has a single partition with 12 cores and 48GB of memory and the CPU is underutilized at 46% with 1000 users. Memory utilization is at 80%. The number of users will increase to 1700, increasing memory utilization by 37%. Which of the following supports this requirement?()A、Active Memory ServerB、Active Memory SharingC、Active Memory PoolingD、Active Memory Expansion

考题 A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A、Dual power supplies.B、Twice the amount of disk.C、Two dual-port LHEA adapters.D、Two dual-port fibre channel adapters.

考题 Company.com has a new computer room that will be used to house a new HACMP cluster. Onceof the outstanding features of the new computer room was the new large air conditioner. This unit has enough excess capacity for more than double the planned amount of equipment. Another feature of this computer room was the dual electric supplies to the room housed in two separate power panels.  How would this impact the overall availability of the environment?()A、 Dual power feeds will make the installation difficult to manage and less high available.B、 The single air conditioner is a single point of failure and the customer should be made aware of the issue.C、 The single air conditioner is a single point of failure and HACMP should be customized to compensate for the issue.D、 A single power feed should be used to avoid ground loops in the computer room causing premature failure of the systems.

考题 Which of the following environments is most closely addressed by the N series N3600?()A、a customer that requires block level storage B、a customer that requires CIFS and AIX NFS environments C、a customer that requires good scalability and performance D、a customer that needs to consolidate multiple storage controllers under a single interface

考题 A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A、Dual power supplies.B、Twice the amount of disk.C、Two dual-port LHEA adapters.D、Two dual-port fibre channel adapters.

考题 A large customer is consolidating their pSeries systems onto a p5 590. They will have a requirement for a single device (disk, lun) to have multiple paths through different  adapters in a single LPAR. The primary applications were written for AIX 5.2. Which of the following would be the recommended solution to satisfy this requirement?()A、Assign the adapters to a Virtual IO partitionB、Use the MPIO function included in AIX 5.2C、Migrate the application to AIX 5.3 and use the MPIO functionD、Set up two Virtual IO partitions and attach both partitions to the device

考题 单选题A large customer is consolidating their pSeries systems onto a p5 590. They will have a requirement for a single device (disk, lun) to have multiple paths through different  adapters in a single LPAR. The primary applications were written for AIX 5.2. Which of the following would be the recommended solution to satisfy this requirement?()A Assign the adapters to a Virtual IO partitionB Use the MPIO function included in AIX 5.2C Migrate the application to AIX 5.3 and use the MPIO functionD Set up two Virtual IO partitions and attach both partitions to the device

考题 单选题A customer has a Power 770 running an SAP ERP workload on AIX 7. It has a single partition with 12 cores and 48GB of memory and the CPU is underutilized at 46% with 1000 users. Memory utilization is at 80%. The number of users will increase to 1700, increasing memory utilization by 37%. Which of the following supports this requirement?()A Active Memory ServerB Active Memory SharingC Active Memory PoolingD Active Memory Expansion

考题 单选题Company.com has a new computer room that will be used to house a new HACMP cluster. Onceof the outstanding features of the new computer room was the new large air conditioner. This unit has enough excess capacity for more than double the planned amount of equipment. Another feature of this computer room was the dual electric supplies to the room housed in two separate power panels.  How would this impact the overall availability of the environment?()A  Dual power feeds will make the installation difficult to manage and less high available.B  The single air conditioner is a single point of failure and the customer should be made aware of the issue.C  The single air conditioner is a single point of failure and HACMP should be customized to compensate for the issue.D  A single power feed should be used to avoid ground loops in the computer room causing premature failure of the systems.

考题 单选题Which of the following environments is most closely addressed by the N series N3600?()A a customer that requires block level storage B a customer that requires CIFS and AIX NFS environments C a customer that requires good scalability and performance D a customer that needs to consolidate multiple storage controllers under a single interface

考题 单选题During consultation, you find that a customer has only a single asset closet and is looking for asolution that is easy to deploy. Which NAS physical deployment model would you suggest to this customer?()A  edgeB  centralC  Layer 2D  Layer 3

考题 单选题A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A Dual power supplies.B Twice the amount of disk.C Two dual-port LHEA adapters.D Two dual-port fibre channel adapters.

考题 单选题A customer has a requirement for a single AIX LPAR to be highly available. The customer only has enough funding to purchase a single system. Which would be the most critical option to mitigate AIX availability?()A Dual power supplies.B Twice the amount of disk.C Two dual-port LHEA adapters.D Two dual-port fibre channel adapters.

考题 单选题A customer has a mixed environment of AIX on POWER4 and POWER5, and x86 based systems running a supported distribution of Linux. There is a total of 7 partitions and three standalone x86 servers. The customer wants to consolidate their applications using a single 4-core POWER6 server.  What is the minimum PowerVM edition that supports the customer requirement?()A  PowerVM Lx86B  PowerVM Express EditionC  PowerVM Standard EditionD  PowerVM Enterprise Edition

考题 单选题Companycom wants to reduce the number of copper, Ethernet adapters on their 4 way p5 570 running AIX 5.3 used in each of the four LPARs. Companycom has one database LPAR, two application LPARs, and one web LPAR. Only the Web LPAR needs to communicate with the outside world. What is the minimum number of Ethernet adapters that should be provided to ensure redundancy and no single point of failure?()A One single port Ethernet adapterB Four dual port Ethernet adaptersC Two single port Ethernet adaptersD Eight single port Ethernet adapters

考题 单选题During consultation, you find that a customer has only a single asset closet and is looking for a solution that is easy to deploy. Which NAS physical deployment model would you suggest to this customer?()A edgeB centralC Layer2D Layer3

考题 单选题A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()A Etherchannel and trunkingB Network Interface Backup and EtherchannelC Shared Ethernet Adapter (SEA) Failover and EtherchannelD Network Interface Backup and Shared Ethernet Adapter failover

考题 单选题A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()A Etherchannel and trunkingB Network Interface Backup and EtherchannelC Shared Ethernet Adapter (SEA) Failover and EtherchannelD Network Interface Backup and Shared Ethernet Adapter failover

考题 单选题Companycom has just purchased a p5 570 with AIX 5.3. The customer would like to add a training LPAR to the system, but no processors are available. All of the partitions are using dedicated resources. The test LPAR is using one processor and has a 90% CPU idle rate. What can be done to setup this training LPAR quickly without disabling their current environment?()A Use AIX 5.3 which supports micro-partitioning for both the test and training LPARSB Use DLPAR to move resources from the test LPAR to training when training is activeC Install Partition Load Manager to share resources between the test and training environmentsD Install Advanced Power Virtualization and then use micro-partitioning for both the test and training LPARs