网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()
A

Run cfgdev on the VIO server and re-run the mkvdev command.

B

Run chdev -a sea_enable=yes on the physical Ethernet adapter.

C

Remove and re-add the virtual Ethernet adapter.

D

Remove the IP address from the physical adapter and re-run the mkvdev command.


参考答案

参考解析
解析: 暂无解析
更多 “单选题Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()A Run cfgdev on the VIO server and re-run the mkvdev command.B Run chdev -a sea_enable=yes on the physical Ethernet adapter.C Remove and re-add the virtual Ethernet adapter.D Remove the IP address from the physical adapter and re-run the mkvdev command.” 相关考题
考题 A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()A、NPIV and vSCSI both require multipathing in VIO Server only. B、NPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. C、NPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. D、NPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

考题 An administrator has recently added a VLAN to the VIO server and wants to update the documentation. Which command displays the current VIO server VLAN configuration?()A、lsmap -allB、lsmap -netC、lsmap -entD、lsmap -vlan

考题 After rebuilding the list of virtual devices used by the VIO server using the "cfgdev" command, which command would be run to verify that a newly configured virtual SCSI adapter is available?()A、lsdev -virtualB、lsdev -Cs scsiC、lscfg -vlD、lsdev -adapter

考题 Company.com has installed and configured a VIO server utilizing a Shared Ethernet Adapter and is investigating some network performance issues visible on the clients. The customer wants to understand the total network connectivity from the clients out to the data center routers.  Which of the following commands will identify the Shared Ethernet Adapter mapping?()A、ifconfig -aB、netstat -nrC、lsmap -all -netD、lsdev -Cc adapter

考题 An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()A、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#B、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameC、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameD、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#

考题 Which of the following has an integrated database?()A、AIXB、IBM iC、LinuxD、VIO Server

考题 Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()A、Allocate the CD to the VIO Server and NFS export the CD to the user LPARsB、Allocate the CD to one of the user LPARs and config the VIO Server to NFS import itC、Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI deviceD、Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs

考题 Best practices would have no single point of failure between mirrored resources. In setting up virtual, internal boot disks for two client LPARs, how would this be accomplished?()A、Have one VIO server with striped disks for all LPARsB、Have one VIO server with mirrored disks for all LPARsC、Have two VIO servers with each LPAR accessing both VIO serversD、Have two VIO servers with each LPAR accessing a different VIO server

考题 Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO  server. Which of the following procedures should be taken to maintain the integrity of the partitions?()A、Shut down all client partitions before updating the VIO server.B、Disconnect the client partitions from any IP networks before updating the VIO server.C、Update the client partitions to the latest OS maintenance level before updating the VIO Server.D、Update the VIO server while the partitions are running, but reboot each client partition at a convenient time after the update.

考题 Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()A、Use DLPAR to avoid an outage.B、Deploy a redundant VIO server in the POWER5 system.C、Add additional Host Bus Adapters and Network adapters to the VIO server.D、Implement a standby server and move all partitions to it before applying future updates.

考题 Companycom is using shared processor LPARs exclusively, including the Virtual IO Server. The users are complaining about response time. The application LPARs can be heavy processor users. The Virtual IO Server has been measured to be processor constrained. How should the Virtual IO Server's shared processor LPAR be configured?()A、Capped and with a lower shareB、Uncapped and with a lower shareC、Uncapped and with a higher shareD、Capped and with no change in share

考题 An administrator is trying to diagnose as to why a new VIO client (vio_client1) cannot see an allocated disk (hdisk4) from a VIO server (VIOS-A). The client virtual SCSI adapter has a slot ID of 5 and the corresponding VIO server virtual SCSI adapter has a slot ID of 3. The administrator checks the virtual SCSI configuration from the HMC using the following lshwres command.  lshwres –r virtualio --rsubtype scsi -m 9117-570*65ABCDE  --level lpar -F / lpar_name,slot_num,remote_lpar_name,remote_slot_num,backing_device VIOS A,5,vio_client2,2,hdisk3 VIOS-A,4,vio_client1,4,hdisk4 VIOS-A,3,vio_client1,6,hdisk5 VIOS-A,2,vio_client3,2,hdisk6 vio_client2,2,VIOS-A,5,hdisk0 vio_client1,4,VIOS-A,4,hdisk0  vio_client1,5,VIOS-A,3,null vio_client3,2,VIOS-A,2,hdisk0 From the output above,  what is the most likely reason why the client cannot see the mapped storage?()A、 The hard disk has been inccorectly mapped on the VIO server.B、 The hard disk has been incorrectly addressed on the VIO client.C、 The client SCSI adapter has been mapped to the incorrect server SCSI adapter.D、 The server SCSI adapter has been mapped to the incorrect client server adapter.

考题 A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()A、A VIO server requires a dedicated LHEA port.B、There is a limit of 32 LPARs per virtual LAN.C、Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D、Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

考题 Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()A、Run cfgdev on the VIO server and re-run the mkvdev command.B、Run chdev -a sea_enable=yes on the physical Ethernet adapter.C、Remove and re-add the virtual Ethernet adapter.D、Remove the IP address from the physical adapter and re-run the mkvdev command.

考题 Company.com has decided to implement virtual hosts in their web server. The current estimate is to create six virtual hosts with unique URL’s and IP addresses. The solution is going to use the IP aliasing faction in HACMP.  How many resource groups are required to support this configuration?()A、 1B、 2C、 6D、 7

考题 单选题A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A  Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B  Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C  Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D  Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 单选题Companycom has a p5 595 with no DVD configured on this server. How can they install the Virtual IO Server code?()A From the HMCB From a NFS mountC From a FTP serverD From any CD or DVD drive on another server

考题 单选题A technical specialist has installed a Host Bus Adapter (HBA) on a p5-550 server. The system has four AIX 5L V5.3 partitions and a Virtual I/O server. The HBA will be used to connect all four partitions to a DS8000 storage array. What else must be performed to make the storage available to the partitions?()A Allocate the HBA to a client partition.B Restart the Virtual I/O Server to detect the changes.C Install the device driver for the DS8000 in each of the four AIX partitions.D Allocate the HBA to the VIO server partition and install necessary drivers.

考题 单选题Upon announcement,the specific details surrounding the Virtual I/O Server requirements and performance are still being defined.  The customer has engaged IBM to provide a server consolidation solution and would like to take advantage of the VIO Server benefits. How should the pSeries technical specialist best address this?()A Design the solution and present it confidently so the customer does not question it.B Design the solution and ensure the customer understands the unknowns with the new technology.C Explain to the customer that the VIO Server does not benefit them when doing server consolidation so it has not been configured.D Explain to the customer that the details surrounding the VIO Server have not been clearly defined so designing a solution is premature.

考题 单选题Company.com network consists of a single Active Directory domain named Company.com.Company.com has an Exchange Server 2010 organization.The Company.com employees use Microsoft Office Outlook 2007 to connect to their mailboxes.RPC over HTTP and Auto discover are configured on Microsoft Office Outlook 2007. Company.com has acquired a new Exchange Server 2010 server and moved the mailboxes to it.However, the employees find a problem to access their mailboxes. What should you do?()A You should consider using Outlook Anywhere and configure it.B You should consider creating and set up a Client Access array.C You should consider renaming the OWA virtual directory to Exchange.D You should consider the Switchover Server option.

考题 单选题Company.com has an EMC disk array and would like to connect it to a Virtual I/O Server on a pSeries p5-520.  How can the EMC device drivers be installed?()A Use smitty install on the client partitions.B Use padmin command in the VIO Server.C Use the oem_setup_env environment in the VIO Server.D Use cfgmgr to detect/configure the devices within the client AIX partition.

考题 单选题A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()A A VIO server requires a dedicated LHEA port.B There is a limit of 32 LPARs per virtual LAN.C Two VIO servers will be required. A single VIO server can only provide virtual storage or Virtual Ethernet.D Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.