网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()

  • A、Run cfgdev on the VIO server and re-run the mkvdev command.
  • B、Run chdev -a sea_enable=yes on the physical Ethernet adapter.
  • C、Remove and re-add the virtual Ethernet adapter.
  • D、Remove the IP address from the physical adapter and re-run the mkvdev command.

参考答案

更多 “ Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()A、Run cfgdev on the VIO server and re-run the mkvdev command.B、Run chdev -a sea_enable=yes on the physical Ethernet adapter.C、Remove and re-add the virtual Ethernet adapter.D、Remove the IP address from the physical adapter and re-run the mkvdev command.” 相关考题
考题 An administrator has decided to use a Shared Ethernet Adapter (SEA) as part of a virtualized environment. Due to the expected traffic across the SEA, the administrator has decided to use an aggregation of two physical Ethernet adapters, ent0 and ent1 as the backing device in the VIO server to increase the available network bandwidth.  Which of the following commands would successfully create an aggregation device within a VIO server? ()A、 mkvdev -lnagg ent0,ent1B、 mkdev -lnagg -d ent0,ent1C、 mkvdev -t etherchannel -a ent0,ent1D、 mkdev -c adapter -s pseudo -t etherchannel ent0,ent1

考题 Companycom has a p5 590 that has their production LPAR, their Tivoli Storage Manager (TSM) LPAR, and several other LPARs. What method would provide connectivity between the production LPAR, and the TSM LPAR, but be isolated from the other LPARs in the system without utilizing a Virtual IO Server or physical adapter resources?()A、Use shared memory and semaphores to transfer the data to the TSM LPARB、Provide gigabit Ethernet adapters in each LPAR and run a crossover cableC、Create a Virtual Ethernet between the production server and the TSM LPARsD、Create a Virtual Ethernet between the TSM server LPAR and the non-production LPARs

考题 Which of the following options applies to virtual Ethernet devices()A、A virtual Ethernet adapter can only connect to other partitions within the same system.B、A virtual Ethernet  adapter needs  to be connected to an external VLAN  capable switch to be able to communicate with other partitions on the same system.C、A partition can support an unlimited number of virtual Ethernet devices.D、A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the "trunk flag" set

考题 A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()A、Etherchannel and trunkingB、Network Interface Backup and EtherchannelC、Shared Ethernet Adapter (SEA) Failover and EtherchannelD、Network Interface Backup and Shared Ethernet Adapter failover

考题 Company.com has installed and configured a VIO server utilizing a Shared Ethernet Adapter and is investigating some network performance issues visible on the clients. The customer wants to understand the total network connectivity from the clients out to the data center routers.  Which of the following commands will identify the Shared Ethernet Adapter mapping?()A、ifconfig -aB、netstat -nrC、lsmap -all -netD、lsdev -Cc adapter

考题 When creating a virtual Ethernet adapter on the HMC for a VIO server, what is the advantage of checking the box to access external network (trunk)?()A、Allows the creation of a shared Ethernet adapterB、Allows the use of VLANsC、Allows the consolidation of multiple networks on one adapterD、Allows EtherChannel load balancing

考题 Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

考题 A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance. Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()A、Order a 2-port 1Gbps Ethernet LAN adapter.B、Order a 2-port 10Gbps Ethernet LAN adapter.C、Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.D、Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

考题 What type of configuration can provide the best availability in a Virtual IO Server environment?()A、Provide multiple paths to all resources through 2 or more Virtual IO ServersB、Mirror all disk resources on the Virtual IO Server to present to the client LPARC、Mirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerD、Trunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

考题 When using a mksysb and base media to clone a system, which of the following will cause the installation to fail()A、mksysb made on a single processor machine but is being installed on a multiple processor machine, no editing of the image.data fileB、mksysb made on machine with mirrored rootvg and new machine only has one disk in rootvg, no editing of the image.data fileC、mksysb made on a machine with 32GB of RAM but being installed on a machine with only 8GB of RAMD、mksysb made on a machine with virtual Ethernet adapter but being installed on a machine which only has a physical Ethernet adapter

考题 When creating a Virtual Ethernet adapter, which of the following steps is done FIRST?()A、Generate a unique MAC address.B、Run cfgmgr to create device special files.C、Create a virtual device with "smitty vlan".D、Add a virtual Ethernet adapter to the partition profile.

考题 Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()A、Configure a Shared Ethernet Adapter on the Virtual I/O Server.B、Use the same virtual LAN ID on each LPAR.C、Set up IP routing through an LPAR on each system.D、Set up an IP firewall through an LPAR on each system.

考题 A system administrator is monitoring a system that has recently shown a decrease in performance. The administrator suspects there is an overload of traffic on a single Ethernet adapter. Which of the following commands is best to identify a possible overload of the Ethernet adapter?()A、pingB、iostatC、netstatD、ifconfig

考题 A technical specialist defined a virtual Ethernet ent2 on the VIO server that has a physical  adapter, ent0. Which of the following commands should be used to configure the Shared Ethernet  Adapter?()A、mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1B、mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1C、mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1D、mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1

考题 Which of the following allows the user to have two separate Ethernet networks share the same network adapter?()A、VLAN tagsB、EtherChannelC、Virtual EthernetD、Shared Ethernet Adapter

考题 A user has an application server LPAR with a physical Ethernet adapter. They want to have a database LPAR also connected to the application LPAR via virtual Ethernet. Their security policies require a firewall between the application LPAR and database LPAR. Which of the following virtual Ethernet configurations satisfies the customer’s requirements?()A、The application server,firewall,and database server on the same VLANB、The application server and firewall on one VLAN,and the database server on a second VLANC、The application server on one VLAN,and the database server and firewall on a second VLAND、The application server and firewall on one VLAN,and the firewall and database server on a second VLAN

考题 When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers,  which of the following attributes must have a different value on both VIO servers?()A、 HA ModeB、 Trunk priorityC、 Control ChannelD、 Default VLAN ID

考题 Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()A、 The physical port can be used as part of a Shared Ethernet Adapter (SEA).B、 All physical ports on the Host Ethernet Adapter (HEA) default to promiscuous mode.C、 Multiple logical ports can be assigned to a physical port if that logical port is in promiscuous mode.D、 All physical ports that belong to the same port group will be set to promiscuous mode on the Host Ethernet Adapter (HEA).

考题 单选题When creating a Virtual Ethernet adapter, which of the following steps is done FIRST?()A Generate a unique MAC address.B Run cfgmgr to create device special files.C Create a virtual device with smitty vlan.D Add a virtual Ethernet adapter to the partition profile.

考题 单选题Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()A Run cfgdev on the VIO server and re-run the mkvdev command.B Run chdev -a sea_enable=yes on the physical Ethernet adapter.C Remove and re-add the virtual Ethernet adapter.D Remove the IP address from the physical adapter and re-run the mkvdev command.

考题 单选题A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance.  Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()A Order a 2-port 1Gbps Ethernet LAN adapter.B Order a 2-port 10Gbps Ethernet LAN adapter.C Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.D Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

考题 单选题An administrator has decided to use a Shared Ethernet Adapter (SEA) as part of a virtualized environment. Due to the expected traffic across the SEA, the administrator has decided to use an aggregation of two physical Ethernet adapters, ent0 and ent1 as the backing device in the VIO server to increase the available network bandwidth.  Which of the following commands would successfully create an aggregation device within a VIO server? ()A  mkvdev -lnagg ent0,ent1B  mkdev -lnagg -d ent0,ent1C  mkvdev -t etherchannel -a ent0,ent1D  mkdev -c adapter -s pseudo -t etherchannel ent0,ent1

考题 单选题Which of the following options applies to virtual Ethernet devices()A A virtual Ethernet adapter can only connect to other partitions within the same system.B A virtual Ethernet  adapter needs  to be connected to an external VLAN  capable switch to be able to communicate with other partitions on the same system.C A partition can support an unlimited number of virtual Ethernet devices.D A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the trunk flag set

考题 单选题A user has an application server LPAR with a physical Ethernet adapter. They want to have a database LPAR also connected to the application LPAR via virtual Ethernet. Their security policies require a firewall between the application LPAR and database LPAR. Which of the following virtual Ethernet configurations satisfies the customer’s requirements?()A The application server,firewall,and database server on the same VLANB The application server and firewall on one VLAN,and the database server on a second VLANC The application server on one VLAN,and the database server and firewall on a second VLAND The application server and firewall on one VLAN,and the firewall and database server on a second VLAN

考题 单选题A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()A Etherchannel and trunkingB Network Interface Backup and EtherchannelC Shared Ethernet Adapter (SEA) Failover and EtherchannelD Network Interface Backup and Shared Ethernet Adapter failover

考题 单选题Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()A Configure a Shared Ethernet Adapter on the Virtual I/O Server.B Use the same virtual LAN ID on each LPAR.C Set up IP routing through an LPAR on each system.D Set up an IP firewall through an LPAR on each system.

考题 单选题A technical specialist defined a virtual Ethernet ent2 on the VIO server that has a physical  adapter, ent0. Which of the following commands should be used to configure the Shared Ethernet  Adapter?()A mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1B mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1C mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1D mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1