A refrigeration unit will tend to short cycle when operating ().
A

under heavy loads

B

during hot gas defrost

C

under light loads

D

during starting conditions


参考答案

参考解析
解析: 暂无解析
更多 “单选题A refrigeration unit will tend to short cycle when operating ().A under heavy loadsB during hot gas defrostC under light loadsD during starting conditions” 相关考题
考题 (c) State one advantage to a business of keeping its working capital cycle as short as possible.(2 Marks)

考题 When the prime movers of two paralleled generators are equipped with mechanical-hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will .A.pick up more of any increase in loadB.pick up less of any increase in loadC.share an equal amount of any increase in loadD.drop an equal amount of any decrease in load

考题 If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

考题 When Bob, a technician, powers up a desktop PC, the unit will repeat three short beeps and will not POST. Which of the following is MOST likely the problem?() A. The memory is failing.B. The CPU is overheating.C. The hard drive is not attached properly.D. The operating system is not installed.

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 In previous times,when fresh meat was inadequate,pigeons were kept by many households as a source of food.A:in short store B:in short provision C:in short reserve D:in short supply

考题 Syllables are short when they are stressed.()

考题 When Bob, a technician, powers up a desktop PC, the unit will repeat three short beeps and will not POST. Which of the following is MOST likely the problem?()A、The memory is failing.B、The CPU is overheating.C、The hard drive is not attached properly.D、The operating system is not installed.

考题 短生活史型(short life-cycle)

考题 单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()A pressurestatB high pressure cutoutC solenoid valveD low pressure cutout switch

考题 单选题Short cycling of a refrigeration compressor refers to ().A frequently grounding outB frequently starting and stoppingC running too fastD running too slow

考题 名词解释题短生活史型(short life-cycle)

考题 单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().A run continuouslyB not startC have high discharge pressureD short cycle on the high pressure switch

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then close until the compressor restartsD always be completely closed until the compressor restarts

考题 单选题Before charging a refrigeration unit, the refrigerant charging lines should be()A flushed with clean refrigerant oilB purged with the refrigerantC washed with an ammonia and alcohol solutionD grounded to compressor

考题 单选题Which cause of following will not lead to refrigeration plant short-cycle?()A lack of refrigerantB refrigerant with much waterC set defectively low pressure relayD no cooling water

考题 单选题In a compression refrigeration cycle, the temperature of the liquid refrigerant experiences its greatest decrease in the().A evaporatorB compressorC expansion valveD condenser

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题When the prime movers of two paralleled generators are equipped with mechanical- hydraulic governors, and are operating within their designed range, the unit with the least amount of speed droop will ().A pick up more of any increase in loadB pick up less of any increase in loadC share an equal amount of any increase in loadD drop an equal amount of any decrease in load

考题 单选题When Bob, a technician, powers up a desktop PC, the unit will repeat three short beeps and will not POST. Which of the following is MOST likely the problem?()A The memory is failing.B The CPU is overheating.C The hard drive is not attached properly.D The operating system is not installed.

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A liquidB dry saturated gasC wet saturated gasD superheated vapor

考题 单选题The pressure range between the system cut in and cut out pressures in a refrigeration unit is known as()A opposing operational dragB pressure distributionC differentialD system purge

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve

考题 单选题For use as protection from gas leaking from a refrigeration unit,each ship must be equipped with a().A portable ventilation systemB flame safety lampC self-contained breathing apparatusD gas mask

考题 单选题Three SHORT BLASTS mean().A I am altering my course to starboardB I am altering my course to portC I am operating astern propulsionD I am operating ahead propulsion