网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A dazzling white burner flame in the boiler furnace indicates ().
A

proper combustion

B

water in the fuel

C

excess air

D

cold fuel oil


参考答案

参考解析
解析: 暂无解析
更多 “单选题A dazzling white burner flame in the boiler furnace indicates ().A proper combustionB water in the fuelC excess airD cold fuel oil” 相关考题
考题 In a()boiler the hot gases from the furnace pass gases from the furnace pass water is on the outside. A.water-tubeB.fire-tubeC.exhaust gasD.composite

考题 In a ______boiler the hot gases from the furnace pass through the tubes while the water is on the outside.A.water-tubeB.fire-tubeC.exhaust gasD.Composite

考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 One of the main advantages of a graphite-furnace atomizer is that()A、It requires only very small quantities of a sampleB、It requires metal.ions in aqueous solutionC、It does not produce background emission like a flameD、It does not get hot like a flame

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题Proper combustion in a boiler would be indicated by ().A yellowish flameB golden yellow flameC white flameD brilliant white flame

考题 单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().A yellowish flameB golden yellow flameC white flameD brilliant white flame

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()A fuel oil supply temperature is normalB burner electrode is incorrectly positionedC fuel/air ratio is incorrectD ignition current is too low

考题 单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A fuel pump failureB fan motor failureC increased feedwater consumptionD decreased boiler efficiency

考题 单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A water in the fuel oilB broken high tension leadsC incorrect electrode settingD full fuel pressure at the nozzle

考题 单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A firing for extended periods in the low fire modeB overheating, due to waterside depositsC varying the water level above the crown sheetD carrying excessive alkalinity in the boiler water

考题 单选题Diesel engine waste heat boiler construction is usually of the fire-tube or()A cyclone furnace boiler typeB dry back boiler typeC water-tube typeD critical circulation boiler type

考题 单选题In a () boiler the hot gases from the furnace pass through the tubes while the water is on the outside.A water-tubeB fire-tubeC exhaust gasD None of the above is true

考题 单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()A cool the furnace to prevent pre-ignitionB remove explosive vapors from the furnaceC evaporate accumulated unburned fuel oilD provide sufficient air in the furnace to allow ignition of the fuel

考题 单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished

考题 单选题The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ().A waterB voltageC fuel pressureD steam pressure

考题 单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A air supply is shut offB fuel supply is shut offC water supply is shut offD safety valve lifts

考题 单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A carbon deposits on the flame scannerB high fuel oil temperatureC low fuel oil viscosityD high steam pressure

考题 单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A defective solenoid valveB dirty fuel nozzleC grounded high tension leadD faulty ignition cable connector

考题 单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy

考题 单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A water in the fuel oilB excessive cyclingC high fuel oil pressureD improper burner maintenance

考题 单选题One of the main purposes of refractories in a boiler furnace is to()A help preheat the air for the furnacesB help preheat the feedwaterC protect economizer from excessive heatD prevent excessive furnace heat losses

考题 单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A incorrect electrode settingB incorrect nozzle positionC clogged fuel nozzleD broken high tension lead

考题 单选题As for a oil-fired boiler too much air would indicated by ().A yellowish flameB golden yellow flameC milky flameD brilliant white flame

考题 单选题The furnace of an oil fired boiler should be () before the operating burner is lit.A filled with waterB purgedC cleared of airD None of the above is true

考题 单选题A dazzling white burner flame in the boiler furnace indicates ().A no combustionB deposits in the fuelC excessive air in the fuelD cold fuel oil