The load between two steam-driven alternators operating in parallel may be adjusted by varying ()
A

the speed of the alternators

B

the field strength of the machines

C

the power factor of the alternators

D

steam supply to the prime movers


参考答案

参考解析
解析: 暂无解析
更多 “单选题The load between two steam-driven alternators operating in parallel may be adjusted by varying ()A the speed of the alternatorsB the field strength of the machinesC the power factor of the alternatorsD steam supply to the prime movers” 相关考题
考题 The division of kilowatt load between two paralleled alternators is determined by theA.amount of field excitation of the leading machineB.load-speed characteristics of the governorsC.amount of field excitation to the lagging machineD.type of alternator

考题 Diesel engines driving alternators operating in parallel must maintain a set frequency regardless of load changes. The governor characteristic used to accomplish this is known as _______.A.actuationB.sensitivityC.compensationD.promptness

考题 The operation of _______two alternators requires the voltages to be equal and also in phaseA.parallelingB.series-mountingC.runningD.controlling

考题 The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ______.A.load limit settingsB.idle speed settingsC.speed limit settingsD.speed droop settings

考题 In which two locations in an enterprise network can an IPS sensor be placed?()A、bridging VLANs on two switchesB、bridging two VLANs on one switchC、between two Layer 2 devices withtrunkingD、between two Layer 2 devices withouttrunkingE、between a Layer 2 device and a Layer 3 device withtrunking

考题 What are two characteristics of Server Load Balancing router mode?()A、 The design supports multiple server subnets Cisco 642-874: Practice ExamB、 An end-user sees the IP address of the real serverC、 SLB routes between the outside and inside subnetsD、 The source or destination MAC address is rewritten, but the IP addresses left aloneE、 SLB acts as a "bump in the wire" between servers and upstream firewall or Layer 3 devices

考题 SQ L*Loader is a utility that can perform which two tasks?()A、Load data from a disk, tape, or named pipes.B、Load data into an Oracle database using DML statements.C、Extract, reorganize, and insert data within an Oracle database.D、Load data from external files into tables in an Oracle database.E、Load data into an Oracle database using operating system commands.F、Load data directly from a non-Oracle database to an Oracle database.

考题 In which two locations in an enterprise network can an IPS sensor be placed? ()A、 bridging VLANs on two switchesB、 bridging two VLANs on one switchC、 between two Layer 2 devices with trunkingD、 between two Layer 2 devices without trunkingE、 between a Layer 2 device and a Layer 3 device with trunking

考题 Which three statements about anycast RP are true? ()A、MSDP is running between anycast RPsB、Anycast RP provides redundancy and load-sharing capabilitiesC、Multicast BGP is running between anycast RPsD、In anycast RP,two or more RPs are configured with the same multicast IP address on loopback interfacesE、In anycast RP,two or more RPs are configured with the same unicast IP address on loopback interfaces

考题 When load balancing traffic between two web servers, which of the following technologies provides the LOWEST cost solution?()A、 Active/passive clusterB、 Active/active clusterC、 Log shippingD、 DNS round robin

考题 Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()A、MulticastB、Active/passive clusterC、Active/active clusterD、DNS round robin

考题 An enterprise has two nodes: -Node ’A’ runs a large relational database and ha six CPUs and  32GB of memory. -Node ’B’ is an application server with three CPU’s and 16GB of memory. During peak production periods, the CPU load for Node ’A’ is normally between 30% and 40%. For Node ’B’, the CPU load is 10% to 20% during peak production periods.  Which of the following describes the best solution for an HACMP cluster?()  A、 Two cluster with two resource groups in a mutual takeover configuration.B、 One cluster with two cascading resource groups in a mutual takeover configuration.C、 One cluster with two rotating resource groups in a one-sided hot standby configuration.D、 Two clusters with two resource groups in a hot-standby configuration with a newly acquired third node.

考题 单选题The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the ().A voltage regulatorsB field rheostatsC reverse power relaysD prime mover governors

考题 单选题Which is a function of the voltage regulators used with AC generators?()A To cut out generators when they are no longer requiredB To cut in additional generators automatically as requiredC To divide the KW load equally between generators operating in parallelD To divide reactive current between generators operating in parallel

考题 单选题The () engine is used for alternators and some times for main propulsion with a gearbox to provide a propeller of between 90 to 120 rpm.A four-strokeB two-strokeC slow speedD reversible

考题 单选题The () engine is used for alternators and sometimes for main propulsion with a gearbox to provide a propeller of between 90 to 120 rpm.A four-strokeB two-strokeC slow speedD reversible

考题 单选题Diesel engines driving alternators operating in parallel must maintain set frequency regardless of load changesThe governor characteristic used to accomplish this is known as ()A actuationB sensitivityC compensationD thrust shaft

考题 单选题Thirty-five percent of the breaking strength of an anchor cable is generally accepted as the().A safe operating loadB normal operating tensionC emergency working loadD allowable storm load

考题 单选题The load sharing characteristics of two diesel generator operating in parallel are mostly dependent on their governor ().A load limit settingsB idle speed settingsC speed limit settingsD speed droop settings

考题 单选题The operation of paralleling two alternators requires the voltages to be ()and also in phase.A zeroB eliminatedC differentD equal

考题 单选题When load balancing traffic between two web servers, which of the following technologies provides the LOWEST cost solution?()A  Active/passive clusterB  Active/active clusterC  Log shippingD  DNS round robin

考题 多选题What are two functions that the parameter max-session performs? ()(Choose two.)ADefines the session limit for the domain.BDefines the session limit for the tunnel instance.CUsed to control load balancing between multiple domains.DUsed to control load balancing between multiple tunnels for a domain.

考题 单选题You have two EBGP peers connected via two parallel serial lines. What should you do to be able to load-balance between two EBGP speakers over the parallel serial lines in both directions? ()A nothing,BGP automatically load-balances the traffic between different autonomous systems on all available linksB peer between the eBGP speaker’s loopbacks, configuring eBGP multihop as required, and use an IGP to load-share between the two equal-cost paths between the loopback addressesC configure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the EBGP peer loopback address;it is also necessary to use the next-hop-self commandD use the ebgp-load-balance command on the neighbor statement on both sidesE configure a loopback as update source for both EBGP peers and have on each AS an IGP to introduce two equal-cost paths to reach the peer loopback address;it is also necessary to use the ebgp-multihop and next-hop-self commands

考题 单选题Which of the following technologies can provide geographically based load balancing with high availability between two web servers with static content?()A  MulticastB  Active/passive clusterC  Active/active clusterD  DNS round robin

考题 单选题Which is the winter load waterline on the load waterline mark?().A The line over the summer load waterlineB The line above the tropical load waterlineC The line below the tropical load waterlineD The line between the summer and the winter north Atlantic load waterline

考题 单选题To equalize the power factor of two alternators operating in parallel, the ()A field excitation of both units is adjustedB governors of both units are adjustedC phase sequence is alteredD kilowatt load is evenly divided

考题 单选题The division of kilowatt load between two paralleled alternators is determined by the ()A amount of field excitation of the leading machineB load-speed characteristics of the governorsC amount of field excitation to the lagging machineD type of alternator