单选题
While you are working in a space,the fixed CO2 system is accidentally activated.You should().
A
Secure the applicators to preserve the charge in the cylinders
B
Continue with your work as there is nothing you can do to stop the flow of CO2
C
Retreat to fresh air and ventilate the compartment before returning
D
Make sure all doors and vents are secured
参考答案
参考解析
解析:
暂无解析
更多 “单选题While you are working in a space,the fixed CO2 system is accidentally activated.You should().A Secure the applicators to preserve the charge in the cylindersB Continue with your work as there is nothing you can do to stop the flow of CO2C Retreat to fresh air and ventilate the compartment before returningD Make sure all doors and vents are secured” 相关考题
考题
I’ll get your RMB for you while you’re ()these forms.
A、taking outB、working outC、filling out
考题
You shouldn’t ______ to others while working.A、stop talkingB、stop to talkC、stop talkD、stop over talk
考题
While on watch in the engine room, you hear a continuous sounding of the general alarm. Which of the following actions should you take?A.Make an entry in the official logbookB.Open the master control valves on the fixed CO2 systemC.Start the fire pump and check discharge pressureD.Secure auxiliary condenser overboard discharge
考题
A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by ______.A.one controlB.two controlsC.three controlsD.none of the above
考题
In the event of fire in a machinery space,______.A.the fixed carbon dioxide system should be used only when all other means of extinguishment have failedB.the fixed carbon dioxide system should be used immediately,as it is the most efficient means of extinguishmentC.water in any form should not be used as it will spread the fireD.the space should be opened 5 minutes after flooding CO2 to prevent injury to personnel
考题
Before using a fixed CO2 system to fight an engine room fire, you must ______.A.secure the engine room ventilationB.secure the machinery in the engine roomC.evacuate all engine room personnelD.All of the above
考题
You have a print server named Server1 that runs Windows Server 2012 R2. You discover that when there are many pending print jobs, the system drive occasionally runs out of free space. You add a new hard disk to Server1. You create a new NTFS volume. You need to prevent the print jobs from consuming disk space on the system volume. What should you modify?()A、the properties of the Print Spooler serviceB、the Print Server PropertiesC、the properties of each shared printerD、the properties on the new volume
考题
()is more accurate and easier than Fixed Interval System ( FIS ) in the order method.A、Fixed Quantity SystemB、Fixed Timing SystemC、Fixed Channel SystemD、Double-note system
考题
You discover an out-of-space condition in the database. You decide to suspend a session for five minutes. You issue the following command to suspend the session: ALTER SESSION ENABLE RESUMABLE; Which command could you issue to enable the resumable space allocation feature at the session level?() A、 ALTER SESSION ENABLE RESUMABLE_TIMEOUT = 5;B、 ALTER SYSTEM ENABLE RESUMABLE_TIMEOUT = 5;C、 ALTER SESSION ENABLE RESUMABLE_TIMEOUT = 300;D、 ALTER SYSTEM ENABLE RESUMABLE TIMEOUT = 300;
考题
单选题Before using a fixed CO2 system to fight an engine room fire,you must().A
secure the engine room ventilationB
secure the machinery in the engine roomC
evacuate all engine room personnelD
All of the above
考题
单选题What’s the _____ of having a public open space where you can’t eat, drink or even simply hang out for a while?A
senseB
matterC
caseD
opinion
考题
单选题If there were a fire in the bunker tanks, you would()A
close the ventB
pump out the tankC
activate the fixed CO2 systemD
cut off the heating coils
考题
单选题Operation of the valve control release on a fixed CO2 system must immediately().A
release CO2 to the protected spaceB
secure all mechanical ventilation in the protected spaceC
sound the rig's general alarm signal for a fireD
sound an alarm in the ballast control room
考题
单选题While on watch in the engine room, you hear a continuous sounding of the general alarmWhich of the following actions should you take?()A
Make an entry in the official logbookB
Open the master control valves on the fixed CO2 systemC
Start the fire pump and check discharge pressureD
Secure auxiliary condenser overboard discharge
考题
单选题In order to release CO2 to the machinery spaces from a fixed fire extinguishing system, you must().A
actuate an alarm and open the engine room control valveB
actuate an alarm and open the engine room CO2 releasing valveC
open the engine room control valve and shut off engine room ventilation fansD
open the engine room control valve and then the CO2 releasing valve
考题
单选题You have a print server named Server1 that runs Windows Server 2012 R2. You discover that when there are many pending print jobs, the system drive occasionally runs out of free space. You add a new hard disk to Server1. You create a new NTFS volume. You need to prevent the print jobs from consuming disk space on the system volume. What should you modify?()A
the properties of the Print Spooler serviceB
the Print Server PropertiesC
the properties of each shared printerD
the properties on the new volume
考题
单选题Actuating the CO2 fixed system causes the shutdown of the().A
fuel supplyB
exhaust ventilationC
supply and exhaust ventilationD
mechanical and natural ventilation
考题
单选题Controls for a fixed carbon dioxide system shall be mounted().A
directly outside the space protected by the systemB
as near the gas cylinders as possibleC
in the pilothouseD
on the main deck near the bow
考题
单选题A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by().A
one controlB
two controlsC
three controlsD
none of the above
考题
单选题On a ship,a cabinet or space containing the controls or valves for the fixed firefighting system must be().A
posted with instructions on the operation of the systemB
ventilated and equipped with explosion-proof switchesC
painted with red and black diagonal stripesD
equipped with a battery powered source of emergency lighting
考题
单选题You have a portable computer that runs Windows XP Professional. When the computer is disconnected from the network, you receive a message in the notification area that says you are working offline. The message reappears every hour. You need to prevent the message from appearing while you are working offline. What should you modify?()A
Disk Quota settingsB
My Documents propertiesC
Offline Files propertiesD
Synchronization settings
考题
多选题On what conditions may an exemption certificate,exempting from the requirement to install a fixed fire extinguishing system in a cargo space,be issued?()AThe ship is constructed and solely intended for carriage of ore, coal, grain, unseasoned timber, non-combustible cargoes or cargoes which according to the Administration constitute a low fire riskBSteel hatch covers and effective means of closing all ventilators and other openings to the cargo space are fittedCA fixed deck foam system is be fitted in lieu of the cargo space extinguishing systemDThe vessel is less than 10 000 gross tonnage
考题
单选题A cabinet or space containing the controls or valves for the fixed firefighting system must be().A
posted with instructions on the operation of the systemB
ventilated and equipped with explosion-proof switchesC
painted with red and black diagonal stripesD
equipped with a battery powered source of emergency lighting
考题
单选题After extinguishing a paint locker fire using the fixed CO2 system,the next action is to have the space().A
opened and burned material removedB
left closed with vents off until all boundaries are coolC
checked for oxygen contentD
doused with water to prevent reflash
考题
单选题Your vessel is equipped with a fixed CO2 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?()A
Use the CO2 system and evacuate the engine roomB
Use the fire main system and evacuate the engine roomC
Evacuate the engine room and use the CO2 systemD
Evacuate the engine room and use the fire main system
考题
单选题You discover an out-of-space condition in the database. You decide to suspend a session for five minutes. You issue the following command to suspend the session: ALTER SESSION ENABLE RESUMABLE; Which command could you issue to enable the resumable space allocation feature at the session level?()A
ALTER SESSION ENABLE RESUMABLE_TIMEOUT = 5;B
ALTER SYSTEM ENABLE RESUMABLE_TIMEOUT = 5;C
ALTER SESSION ENABLE RESUMABLE_TIMEOUT = 300;D
ALTER SYSTEM ENABLE RESUMABLE TIMEOUT = 300;
考题
单选题While on watch in the engine room, you hear a continuous sounding of the general alarmWhich of the following actions should you take FIRST?()A
Secure the burners then proceed to your assigned boat stationB
Start the fire pump and establish flow to the fire mainC
Open the guardian valve and standby to maneuverD
Open the master control valves on the fixed CO2 system