网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
After extinguishing a paint locker fire using the fixed CO2 system,the next action is to have the space().
A

opened and burned material removed

B

left closed with vents off until all boundaries are cool

C

checked for oxygen content

D

doused with water to prevent reflash


参考答案

参考解析
解析: 暂无解析
更多 “单选题After extinguishing a paint locker fire using the fixed CO2 system,the next action is to have the space().A opened and burned material removedB left closed with vents off until all boundaries are coolC checked for oxygen contentD doused with water to prevent reflash” 相关考题
考题 Paints and solvents on a vessel should be ______.A.stored safely at the work site until work is completedB.returned to the paint locker after each useC.covered at all times to protect from ignition sourcesD.stored in a suitable gear locker

考题 In the event of fire in a machinery space,______.A.the fixed carbon dioxide system should be used only when all other means of extinguishment have failedB.the fixed carbon dioxide system should be used immediately,as it is the most efficient means of extinguishmentC.water in any form should not be used as it will spread the fireD.the space should be opened 5 minutes after flooding CO2 to prevent injury to personnel

考题 Which of the following statements is FALSE,concerning the regulations pertaining to the cylinder room of a fixed CO2 fire extinguishing system ________.A.The compartment must be properly ventilatedB.The temperature of the room should never exceed 130℉C.The door must be kept unlockedD.The compartment shall be clearly marked and identifiable

考题 A galley grease fire on the stove may be extinguished using______.A.waterB.foamC.the range hood extinguishing systemD.fire dampers

考题 After extinguishing a fire with CO2, it is advisable to ______.A.use all CO2 available to cool the surrounding areaB.stand by with water or other agentsC.thoroughly ventilate the space of CO2D.jettison all burning materials

考题 Before using a fixed CO2 system to fight an engine room fire, you must ______.A.secure the engine room ventilationB.secure the machinery in the engine roomC.evacuate all engine room personnelD.All of the above

考题 Paint is stowed in the paint locker, which is usually situated ().A、under the bridgeB、at the bowC、under the forecastleD、at the stern

考题 Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

考题 单选题Before using a fixed CO2 system to fight an engine room fire,you must().A secure the engine room ventilationB secure the machinery in the engine roomC evacuate all engine room personnelD All of the above

考题 单选题Each hand portable,semi-portable and fixed fire extinguishing unit on a ship must be tested and inspected at least once every().A six weeksB six monthsC twelve monthsD two years

考题 单选题Which firefighting method is an example of an indirect attack on a fire?().A Bouncing a straight stream of water off the overhead to create spray effectB Spraying foam on a bulkhead and letting it flow down and over a pool of burning oilC Flooding a paint locker with CO2 and sealing the compartmentD Cooling adjacent bulkheads with water to prevent the spread of the fire by conduction

考题 单选题The remote control for a fixed fire extinguishing system should be().A painted red and labeledB concealed from the crewC protected by plexiglassD padlocked

考题 单选题A galley grease fire on the stove may be extinguished using().A waterB foamC the range hood extinguishing systemD fire dampers

考题 单选题When should a fire be ventilated?()A When attacking the fire directlyB When using a steam smothering systemC When using the fixed CO2 systemD All of the above

考题 单选题In order to release CO2 to the machinery spaces from a fixed fire extinguishing system, you must().A actuate an alarm and open the engine room control valveB actuate an alarm and open the engine room CO2 releasing valveC open the engine room control valve and shut off engine room ventilation fansD open the engine room control valve and then the CO2 releasing valve

考题 单选题Fixed CO2 systems would not be used on crew’s quarters or().A the paint lockerB spaces open to the atmosphereC cargo holdsD the engine room

考题 多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

考题 单选题A crew member reports that the high-pressure alarm light of a low-pressure CO2 fixed fire extinguishing system is illuminated. The most probable cause of this condition would be that().A an air leak has developed in the tankB the tank cooling system has malfunctionedC the pilot cylinder discharge valve is leakingD an excessive amount of insulation has been installed on the tank and piping

考题 单选题The fire extinguishing action of CO2 comes mostly from ().A breaking the fire chemical chain reactionB smotheringC coolingD isolating the heat from the fuel

考题 单选题Which of the listed extinguishing agents is NOT suitable for fighting a liquid paint fire?()A Dry chemicalB FoamC WaterD Carbon dioxide

考题 单选题If a small fire initially breaks out in the engine room bilges, in which of the following sequences should the fire extinguishing agents or systems be used?()A Fixed CO2,semi-portable CO2, then hand portable CO2B Semi-portable CO2, fixedCO2, then hand portable CO2C Hand portable, semi-portable CO2, then as a last resort the fixed CO2 systemD Hand portable, fixed CO2, then as a last resort the semi-portable CO2

考题 多选题On what conditions may an exemption certificate,exempting from the requirement to install a fixed fire extinguishing system in a cargo space,be issued?()AThe ship is constructed and solely intended for carriage of ore, coal, grain, unseasoned timber, non-combustible cargoes or cargoes which according to the Administration constitute a low fire riskBSteel hatch covers and effective means of closing all ventilators and other openings to the cargo space are fittedCA fixed deck foam system is be fitted in lieu of the cargo space extinguishing systemDThe vessel is less than 10 000 gross tonnage

考题 单选题Paints and solvents on a vessel should be().A stored safely at the work site until work is completedB returned to the paint locker after each useC covered at all times to protect from ignition sourcesD stored in a suitable gear locker

考题 单选题Your vessel is equipped with a fixed CO2 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?()A Use the CO2 system and evacuate the engine roomB Use the fire main system and evacuate the engine roomC Evacuate the engine room and use the CO2 systemD Evacuate the engine room and use the fire main system

考题 单选题You are ordering ships’ stores that are NOT consumer commodities. Which statement is TRUE?()A All flammable liquids must be stowed in the paint locker or specially constructed integral tanksB The label of a hazardous ships' store must include instructions for safe stowageC Replacement CO2 cylinders for the fixed fire fighting system must have been tested within 8 years of receiptD Cartridges for the line throwing appliance must be stored in the portable magazine chest after receipt

考题 单选题After extinguishing a fire with CO2,it is advisable to().A use all CO2 available to cool the surrounding areaB stand by with water or other agentsC thoroughly ventilate the space of CO2D jettison all burning materials

考题 单选题After extinguishing a fire with C02,it is availabe to().A use all CO2 available to cool the surronding areaB stand by with water or other agentsC thoroughly ventilate the space of CO2D jettison all buring materials