网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000.  What is the maximum number of volumes that can be used on the Solaris host()
A

256

B

512

C

1024

D

2048


参考答案

参考解析
解析: 暂无解析
更多 “单选题A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000.  What is the maximum number of volumes that can be used on the Solaris host()A 256B 512C 1024D 2048” 相关考题
考题 The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A、check the output of the vmstat command on AIXB、check the performance reports via TotalStorage Productivity Center for DataC、check the performance reports via TotalStorage Productivity Center for DiskD、check the improvement through the TotalStorage Expert report

考题 When doing capacity planning for the Virtual I/O Server,what is the most important  consideration?()A、The I/O workload needs of the client LPARsB、The processing requirements of the client LPARsC、The memory requirements of the client LPARsD、The virtual Ethernet requirements between client LPARs

考题 A customer has bought an IBM System Storage DS8700 and wants to attach ten SuSE Linux Enterprise Server hosts to the DS8700 with multiple paths.  What is the Multipathing Driver the customer needs()A、PowerPathB、Subsystem Device Driver Device Specific ModuleC、Subsystem Device Driver Path Control ModuleD、DeviceMapper Multipath

考题 An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

考题 A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000.  What is the maximum number of volumes that can be used on the Solaris host()A、256B、512C、1024D、2048

考题 A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000.  Where can the sales representative find this information()A、IBM System Storage DS8000: Introduction and Planning GuideB、IBM DS8000 Interoperability Matrix on the support page on the webC、IBM System Storage DS8000: User’s GuideD、IBM System Storage DS8000: Solution Assurance Guide

考题 A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A、the IBM System Storage DS8000 Interoperability MatrixB、the IBM System Storage DS8000 Introduction and Planning GuideC、the IBM System Storage DS8000 Host System Attachment GuideD、the IBM System Storage DS8000 User’s Guide

考题 A customer wants to purchase an IBM System Storage DS8000. The proposed location is in a data center on the third floor of an office building.  Which document should the storage specialist consult to ensure that the DS8000 can be installed in the proposed location()A、IBM Announcement LettersB、IBM DS8000 Installation GuideC、IBM DS8000 Introduction and Planning GuideD、IBM Systems Storage Solutions Handbook

考题 The storage specialist needs to prepare an IBM System Storage DS8800 proposal including 64 host ports. The offer needs to meet the lowest possible price.  What is the minimum number of I/O Enclosure Pairs PCI-E for this configuration()A、one I/O enclosure pair PCI-EB、two I/O enclosure pairs PCI-EC、four I/O-enclosure pairs PCI-ED、eight I/O-enclosure pairs PCI-E

考题 A customer has the need for performance monitoring of an IBM System Storage DS8000.  Which product does the customer need()A、System Storage Productivity CenterB、Tivoli Storage Productivity Center for DataC、Tivoli Storage Productivity Center for DiskD、Tivoli Storage Productivity Center for Fabric

考题 What is the correct order to create an object in a new IBM System Storage DS8000 to get a LUN provided to a host()A、rank, array, extent pool, volumes, volume group, host connectionsB、rank, array, extent pool, volume group, volumes, host connectionsC、array, rank, extent pool, volume group, volumes, host connectionsD、array, extent pool, volumes, rank, volume group, host connections

考题 A customer with a small IT budget has one data center. Their main application is a database running on an IBM System Storage DS8000. The database has a data change rate of 50% per day. Once a week, they must do a point-in-time backup from the database to tape. The time it takes to run the backup now exceeds the backup window allowed. The customer requests a proposal to reduce database downtime caused by running backups, with nearly no impact to production volumes.    In addition to the tape backup, which DS8000 feature should a technical specialist propose()A、FlashCopyB、FlashCopy SEC、Metro MirrorD、Global Mirror

考题 A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A、2B、4C、6D、8

考题 单选题A technical specialist has installed a Host Bus Adapter (HBA) on a p5-550 server. The system has four AIX 5L V5.3 partitions and a Virtual I/O server. The HBA will be used to connect all four partitions to a DS8000 storage array. What else must be performed to make the storage available to the partitions?()A Allocate the HBA to a client partition.B Restart the Virtual I/O Server to detect the changes.C Install the device driver for the DS8000 in each of the four AIX partitions.D Allocate the HBA to the VIO server partition and install necessary drivers.

考题 单选题The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A check the output of the vmstat command on AIXB check the performance reports via TotalStorage Productivity Center for DataC check the performance reports via TotalStorage Productivity Center for DiskD check the improvement through the TotalStorage Expert report

考题 单选题A client has bought an IBM System Storage DS8000 and needs to attach a Sun Solaris Host with 2 HBAs via one fabric to 4 I/O ports on the DS8000. The client needs redundant paths to the volumes on the DS8000.  What is the maximum number of volumes that can be used on the Solaris host()A 256B 512C 1024D 2048

考题 单选题An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A IBM System Storage DS8000: Host Systems Attachment GuideB DS8000 Interoperability MatrixC IBM System Storage DS8000: Introduction and Planning GuideD IBM System Storage Solution Handbook

考题 单选题A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A the IBM System Storage DS8000 Interoperability MatrixB the IBM System Storage DS8000 Introduction and Planning GuideC the IBM System Storage DS8000 Host System Attachment GuideD the IBM System Storage DS8000 User’s Guide

考题 单选题A customer with a small IT budget has one data center. Their main application is a database running on an IBM System Storage DS8000. The database has a data change rate of 50% per day. Once a week, they must do a point-in-time backup from the database to tape. The time it takes to run the backup now exceeds the backup window allowed. The customer requests a proposal to reduce database downtime caused by running backups, with nearly no impact to production volumes.    In addition to the tape backup, which DS8000 feature should a technical specialist propose()A FlashCopyB FlashCopy SEC Metro MirrorD Global Mirror

考题 单选题The storage specialist needs to prepare an IBM System Storage DS8800 proposal including 64 host ports. The offer needs to meet the lowest possible price.  What is the minimum number of I/O Enclosure Pairs PCI-E for this configuration()A one I/O enclosure pair PCI-EB two I/O enclosure pairs PCI-EC four I/O-enclosure pairs PCI-ED eight I/O-enclosure pairs PCI-E

考题 单选题What is the correct order to create an object in a new IBM System Storage DS8000 to get a LUN provided to a host()A rank, array, extent pool, volumes, volume group, host connectionsB rank, array, extent pool, volume group, volumes, host connectionsC array, rank, extent pool, volume group, volumes, host connectionsD array, extent pool, volumes, rank, volume group, host connections

考题 单选题A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000.  Where can the sales representative find this information()A IBM System Storage DS8000: Introduction and Planning GuideB IBM DS8000 Interoperability Matrix on the support page on the webC IBM System Storage DS8000: User’s GuideD IBM System Storage DS8000: Solution Assurance Guide

考题 单选题A pharmaceutical company has a requirement for 8.5 TB of usable storage for a new data center. The customer has multiple host applications running on Solaris, Windows 2003, HP-U/X, Linux, and IBM System i platforms.  Which IBM System Storage DS8000 volume configuration providesthe best performance and highest availability for this customer()A RAID 3B RAID 5C RAID 6D RAID 10

考题 单选题A customer wants to purchase an IBM System Storage DS8000. The proposed location is in a data center on the third floor of an office building.  Which document should the storage specialist consult to ensure that the DS8000 can be installed in the proposed location()A IBM Announcement LettersB IBM DS8000 Installation GuideC IBM DS8000 Introduction and Planning GuideD IBM Systems Storage Solutions Handbook

考题 单选题A customer has bought an IBM System Storage DS8700 and wants to attach ten SuSE Linux Enterprise Server hosts to the DS8700 with multiple paths.  What is the Multipathing Driver the customer needs()A PowerPathB Subsystem Device Driver Device Specific ModuleC Subsystem Device Driver Path Control ModuleD DeviceMapper Multipath

考题 单选题A customer has the need for performance monitoring of an IBM System Storage DS8000.  Which product does the customer need()A System Storage Productivity CenterB Tivoli Storage Productivity Center for DataC Tivoli Storage Productivity Center for DiskD Tivoli Storage Productivity Center for Fabric

考题 单选题When doing capacity planning for the Virtual I/O Server,what is the most important  consideration?()A The I/O workload needs of the client LPARsB The processing requirements of the client LPARsC The memory requirements of the client LPARsD The virtual Ethernet requirements between client LPARs

考题 单选题A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A 2B 4C 6D 8