网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()
A

check the output of the vmstat command on LINUX

B

check the performance reports via Tivoli Storage Productivity Center for Data

C

check the performance reports via Tivoli Storage Productivity Center for Disk

D

check the output of the iostat command on AIX


参考答案

参考解析
解析: 暂无解析
更多 “单选题The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A check the output of the vmstat command on LINUXB check the performance reports via Tivoli Storage Productivity Center for DataC check the performance reports via Tivoli Storage Productivity Center for DiskD check the output of the iostat command on AIX” 相关考题
考题 The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A、check the output of the vmstat command on AIXB、check the performance reports via TotalStorage Productivity Center for DataC、check the performance reports via TotalStorage Productivity Center for DiskD、check the improvement through the TotalStorage Expert report

考题 A customer has an IBM System Storage DS8700 and wants to reach the highest possible throughput in the back-end for a storage-pool-striped volume out of an extent pool with 8 ranks.  Over how many device adapter pairs should a technical specialist spread the workload()A、2B、4C、6D、8

考题 A healthcare provider has two applications that they need to redundantly protect in a SAN environment. Their patient record application runs on Oracle 11i and consists of many small, randomly accessed files. The database is kept on three clustered Sun servers and currently uses 30 TB of data space. Their imaging application that retains and manages x-rays, consists of Filenet, CommonStore, and TSM running on an IBM Power750 server, and is currently using 65 TB of data space.  Which of the following disk solutions meets the customer’s requirement()A、IBM System Storage DS8700 2 wayB、IBM System Storage DCS9900C、IBM System Storage DS8700 4 wayD、IBM XIV Storage System

考题 The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A、check the output of the "vmstat" command on LINUXB、check the performance reports via Tivoli Storage Productivity Center for DataC、check the performance reports via Tivoli Storage Productivity Center for DiskD、check the output of the "iostat" command on AIX

考题 An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

考题 A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A、Tivoli Storage ManagerB、Tivoli Storage Productivity Center for DiskC、Tivoli Storage Productivity Center Basic EditionD、Tivoli Storage Productivity Center Standard Edition

考题 A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()A、perform a Disk Magic study B、review eConfig with a technical specialist C、confirm that the customer has enough ports available in the SAN infrastructure D、submit configuration to IBM System Storage Interoperability Center for validation

考题 Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A、AIXB、IBM iC、LinuxD、VIO Server

考题 A Business Partner storage specialist is proposing an IBM System Storage DS5000 solution to aninstalled EMC customer. Which IBM resource should the Business Partner engage to assist withcompetitive sales strategies against EMC?()A、Competeline B、Executive Briefing Center C、Competitive Benchmark Center D、Field Technical Support Specialist (FTSS)

考题 A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A、the IBM System Storage DS8000 Interoperability MatrixB、the IBM System Storage DS8000 Introduction and Planning GuideC、the IBM System Storage DS8000 Host System Attachment GuideD、the IBM System Storage DS8000 User’s Guide

考题 Select the IBM resource designed for small-to-medium business segments that helps identify System x server and storage for customers’ specific needs:()A、IBM System Advisor ToolB、IBM System x and BladeCenter Business Partner GuidebookC、Standalone Solutions Configuration Tool (SSCT)D、Configuration  Options Guide (COG)

考题 An IBM Business Partner sells an IBM System Storage DS8700 to a customer.  Who is responsible for the installation and set up of the storage server()A、purchasing customerB、IBM Installation Readiness TeamC、IBM Customer EngineerD、IBM Business Partner

考题 A customer using an IBM System Storage DS8700 is facing performance problems. After the analysis by the technical specialist, the diagnosis indicates that the cache hits may be improved by a cache upgrade.  How can the system be monitored in order to check the benefits of the cache upgrade()A、using the "vmstat" command on the AIX servers connected via SAN to the DS8700 systemB、look at the IOPS using the DS8700C、reading the performance reports via Tivoli Storage Productivity Center for DiskD、generating reports using theTotalStorage Expert

考题 A customer with both IBM servers and storage asked their storage specialist to present updatedinformation on the IBM storage portfolio. The specialist suspects a competitor is actively selling inthis account. Which of the following questions, if asked by the customer, would most likely indicatecompetitive activity?()A、Does the DS8700 offer virtualized arrays? B、How can the IBM SAN Volume Controller work in our environment? C、What is the raw disk capacity of the IBM System Storage DS5300? D、What are the support options available on the IBM System Storage DS5020?

考题 A UNIX customer has a Symmetrix DMX that has crashed three times in the past six months, causing data loss. The customer is shopping for an enterprise storage solution to provide point-in- time copy functionality without a fixed relationship to its primaries.  Which IBM solution best meets this customer’s requirements()A、IBM System Storage DS8700 andVolumeCopyB、IBM System Storage DS8700 andFlashCopyC、IBM System Storage DS8700 andFlashCopy with the NoCopy optionD、IBM System Storage DS8700 andFlashCopy with the Persistent option

考题 A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()A、an IBM System Storage DS8700 with LTO tape driveB、an IBM System Storage DS8700 with FlashCopy ManagerC、an IBM XIV Storage SystemD、an IBM XIV Storage System with SAN Volume Controller

考题 The pSeries technical specialist of a Premier Tier 1 Business Partner has been working on a design for a four LPAR p5-570 Express solution.  The specialist has received conflicting information regarding sharing the IDE DVD-RAM drive between different LPARs.  Who should the technical specialist contact to gain a definitive answer?()A、IBM BPSOB、IBM PartnerlineC、IBM DistributorD、IBM Supportline

考题 单选题A customer has an IBM System Storage DS8700 and wants to reach the highest possible throughput in the back-end for a storage-pool-striped volume out of an extent pool with 8 ranks.  Over how many device adapter pairs should a technical specialist spread the workload()A 2B 4C 6D 8

考题 单选题The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A check the output of the vmstat command on AIXB check the performance reports via TotalStorage Productivity Center for DataC check the performance reports via TotalStorage Productivity Center for DiskD check the improvement through the TotalStorage Expert report

考题 单选题A Business Partner storage specialist is proposing an IBM System Storage DS5000 solution to aninstalled EMC customer. Which IBM resource should the Business Partner engage to assist withcompetitive sales strategies against EMC?()A Competeline B Executive Briefing Center C Competitive Benchmark Center D Field Technical Support Specialist (FTSS)

考题 单选题The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A check the output of the vmstat command on LINUXB check the performance reports via Tivoli Storage Productivity Center for DataC check the performance reports via Tivoli Storage Productivity Center for DiskD check the output of the iostat command on AIX

考题 单选题An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A IBM System Storage DS8000: Host Systems Attachment GuideB DS8000 Interoperability MatrixC IBM System Storage DS8000: Introduction and Planning GuideD IBM System Storage Solution Handbook

考题 单选题A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A the IBM System Storage DS8000 Interoperability MatrixB the IBM System Storage DS8000 Introduction and Planning GuideC the IBM System Storage DS8000 Host System Attachment GuideD the IBM System Storage DS8000 User’s Guide

考题 单选题An IBM Business Partner sells an IBM System Storage DS8700 to a customer.  Who is responsible for the installation and set up of the storage server()A purchasing customerB IBM Installation Readiness TeamC IBM Customer EngineerD IBM Business Partner

考题 单选题A customer with both IBM servers and storage asked their storage specialist to present updatedinformation on the IBM storage portfolio. The specialist suspects a competitor is actively selling inthis account. Which of the following questions, if asked by the customer, would most likely indicatecompetitive activity?()A Does the DS8700 offer virtualized arrays? B How can the IBM SAN Volume Controller work in our environment? C What is the raw disk capacity of the IBM System Storage DS5300? D What are the support options available on the IBM System Storage DS5020?

考题 单选题A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()A perform a Disk Magic study B review eConfig with a technical specialist C confirm that the customer has enough ports available in the SAN infrastructure D submit configuration to IBM System Storage Interoperability Center for validation

考题 单选题A customer recently installed new a SAN with an IBM System Storage DS8700 and several open systems servers to address a need for storage consolidation and still provide good response time. They have asked the Business Partner technical representative for the most complete IBM product that would allow them to do performance reporting of the new SAN environment.  What is the best solution()A Tivoli Storage ManagerB Tivoli Storage Productivity Center for DiskC Tivoli Storage Productivity Center Basic EditionD Tivoli Storage Productivity Center Standard Edition

考题 单选题A customer using an IBM System Storage DS8700 is facing performance problems. After the analysis by the technical specialist, the diagnosis indicates that the cache hits may be improved by a cache upgrade.  How can the system be monitored in order to check the benefits of the cache upgrade()A using the vmstat command on the AIX servers connected via SAN to the DS8700 systemB look at the IOPS using the DS8700C reading the performance reports via Tivoli Storage Productivity Center for DiskD generating reports using theTotalStorage Expert