If the coolant temperature of a closed cooling water system for a diesel engine gradually increases, the trouble usually is ()
A

a broken shaft on the freshwater pump

B

an excessive accumulation of scale exchanger

C

an incorrect thermostatic element operating range

D

lube oil in the cooling water


参考答案

参考解析
解析: 暂无解析
更多 “单选题If the coolant temperature of a closed cooling water system for a diesel engine gradually increases, the trouble usually is ()A a broken shaft on the freshwater pumpB an excessive accumulation of scale exchangerC an incorrect thermostatic element operating rangeD lube oil in the cooling water” 相关考题
考题 What is head tank in the closed cooling water system used for?A.for the release of air from the cooling waterB.providing expansion room for heated cooling waterC.a place for implementing water and water treatment agentD.all of the above

考题 If the coolant temperature of a closed cooling water system for a diesel enginegradually increases, the trouble usually is( ).A.a broken shaft on the freshwater pumpB.an excessive accumulation of scale in the heat exchangerC.an incorrect thermostatic element operating rangeD.lube oil in the cooling water

考题 In a diesel engine closed freshwater cooling system, the amount of coolant flowing through the heat exchanger is controlled by the __.A.suction pressure regulatorB.thermostatic bypass valveC.sea water temperatureD.water level in the expansion tank

考题 The most serious effect of air trapped in a diesel engine jacket water cooling system is that it ______.A.Causes colloid suspension in the cooling waterB.Reduces the capability of the lubrication systemC.Can form pockets which block the flow of coolant through the systemD.Leads to the scuffing of cylinder walls

考题 单选题The pH value of water in a diesel engine closed cooling water system should be maintained between ().A 60 to75B 80 to 95C 100 to 115D 120 to 135

考题 单选题What is head tank in the closed cooling water system used for?()A for the release of air from the cooling waterB providing expansion room for heated cooling waterC a place for implementing water and water treatment agentD all of the above

考题 单选题In a closed cooling water system, which of the problems can cause the water pressure to fluctuate?()A An open vent in the cooling systemB A fouled sea chestC A restricted water passage in the engineD Air entrained in the cooling water

考题 单选题In the closed cooling system, the water ().A is made to circulate out of the systemB is made to circulate within the systemC is made circulate within the systemD is made circulate out of the system

考题 单选题The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the ().A fresh water expansion tankB sea water expansion tankC thermostatic expansion valveD jacket water cooler accumulator

考题 单选题If the operating element of a thermostatic valve installed in a diesel engine cooling system malfunctions, it may result in ()A a low level in the engine expansion tankB excessively high coolant pressureC improper temperaturesD malfunctioning of the jacket water heater

考题 单选题If the jacket water temperature in an auxiliary diesel engine cooling system is lower than normal, the probable cause is ()A air binding of the engine cooling systemB a cracked water cooled exhaust manifoldC blockage in the heat exchangerD faulty operation of the thermostat

考题 单选题The most serious effect of air trapped in a diesel engine jacket water cooling system is that it().A causes colloid suspension in the cooling waterB reduces the capability of the lubrication systemC can form pockets which block the flow of coolant through the systemD leads to the scuffing of cylinder walls

考题 单选题In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()A improper venting of the cooling systemB carrying the expansion tank water level too highC a totally clogged impeller in the cooling water pumpD an incorrectly set cooling system temperature control

考题 单选题The expansion tank for a diesel engine closed cooling system is designed to maintain a constant head on the system and ().A reduce water temperatureB reduce water turbulenceC provide an air cushionD allow for an increase in water volume as the engine warms up

考题 单选题The outlet from an expansion tank of a closed freshwater cooling system should be piped to the ().A cylinder head water outlet headerB cylinder jacket inlet mainC heat exchanger inlet connectionD jacket water pump suction line

考题 单选题The highest pressure in any closed diesel engine freshwater cooling system is at the ().A jacket water outletB expansion tank inletC heat exchanger inletD cooling water pump outlet

考题 单选题In a diesel engine cooling system, the high temperature alarm contact maker will be activated on excessively high water discharge temperature from the ()A raw water pump dischargeB expansion tank outletC cooling water heat exchangerD outlet engine jacket water outlet

考题 单选题If the water level dropped rapidly in the expansion tank of a closed diesel engine cooling water system, you should suspect a ().A loss of suction in the circulating pumpB leak in the primary cooling systemC broken raw water pump shaftD burned or cracked piston in one cylinder

考题 单选题Which of the following methods is normally used to control the temperature of air distributed from individual cooling coils in an air conditioning system using a chilled water circulation system?()A A room thermostat activates an electric heater at each individual chilled air outlet when necessaryB Varying the number of passes the air makes across the coilsC Varying the temperature of the water through the coilsD Varying the quantity of water flowing through the coils

考题 单选题Which of the following problems can cause fluctuating pressures in the closed cooling system of a main propulsion diesel engine?()A Defective temperature controls in the systemB Cavitation in the cooling water pumpC Opened vent in the cooling systemD Restricted water passages in the engine

考题 单选题In a closed diesel engine freshwater cooling system, the amount of coolant flowing through the heat exchanger is controlled by the ().A suction pressure regulatorB thermostatic bypass valveC sea water temperatureD water level in the expansion tank

考题 单选题Temperature control valves installed in the jacket cooling water system of a diesel engine modulates the rate of water flow through the ().A cooling water pumpB nozzle cooling passagesC cylinder jacketsD heat exchanger

考题 单选题In a refrigeration system, if the cooling water to the condenser fails, the().A box temperature solenoid valve will closeB expansion valve will closeC compressor will shutdownD king valve will open

考题 单选题Operating a diesel engine for prolonged periods, with a closed freshwater cooling system, at temperatures lower than the normal design temperature can cause ().A the formation of sulfuric acidB a decrease in lube oil viscosityC a decrease in cooling water pHD a thermostat failure

考题 单选题In any diesel engine closed freshwater cooling system, the lowest pressure exists at the ().A jacket water outletB cooling water pump outletC heat exchanger outletD expansion tank atmospheric vent

考题 单选题If the compressor-discharge temperature is higher than the receiver temperature()A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some of the refrigerant from the system

考题 单选题The jacket water temperature in a diesel engine closed freshwater cooling system is normally controlled by ()A regulating the level of corrosion inhibitor in the primary cooling systemB the level of the freshwater expansion tankC varying the engine load to meet temperature requirementsD the operation of the thermostatic valve