A customer purchased a new IBM xSeries x445.  They already have a non-IBM industry standard rack with 14U of open space that is being considered to house the new server.  The rack houses an existing UPS unit for the entire rack.  Which of the following questions is most important to ensure that the power in the datacenter environment is ready for the initial install?()

  • A、Have optional Fibre Channel and Ethernet switches been installed in the server?
  • B、What is the available kVA value of the UPS?
  • C、Are there sufficient empty socket outlets in the UPS?
  • D、What is the impact on the power consumption of the data center cooling system?

参考答案

更多 “A customer purchased a new IBM xSeries x445.  They already have a non-IBM industry standard rack with 14U of open space that is being considered to house the new server.  The rack houses an existing UPS unit for the entire rack.  Which of the following questions is most important to ensure that the power in the datacenter environment is ready for the initial install?()A、Have optional Fibre Channel and Ethernet switches been installed in the server?B、What is the available kVA value of the UPS?C、Are there sufficient empty socket outlets in the UPS?D、What is the impact on the power consumption of the data center cooling system?” 相关考题
考题 Which of the following is the MOST important physical consideration when deploying a new server?() A. Humidity monitors, Biometrics, and fire suppressionB. Cooling, rack space, and power requirementsC. Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD. Biometrics, fire suppression, and power requirements

考题 A medical customer has a rack with four BladeCenter H chassis that have been operating normally for several months. After installing a new rack of servers in the data center, the system administrator notices the blowers in the BladeCenters have increased their speed. Which of the following caused this problem? ()A、The room temperature has reached 23C (73.4F). B、A Blade within the chassis has been shut down. C、The ambient temperature in the data center has increased D、One of the additional System X servers in the BladeCenter rack has failed.

考题 A customer is planning to implement a new x445 in their datacenter.Which TWO of the following should the customer prepare prior to the implementation to ensure a trouble free installation?()A、Install the exhaust fan on top of the IBM NetBAY 42 Enterprise rack for extra coolingB、Ensure a 260V power source for the x445 and BladeCenter is available for fully redundant powerC、Ensure a 220v power source for the x445 is available for fully redundant powerD、Install the new 10GBit Ethernet network to take advantage of the new network switch in the x445.E、Have their Network Operation Staff review and assist connecting the new server to their existing network.

考题 A customer recently purchased a new x3550 M3 server and one of the hard drives has failed. The customer has a standard warranty. They called you asking for a replacement. Which action should the customer take?()A、Contact the IBM FTSS to replace the driveB、Contact the IBM CSR or SSR to replace the driveC、Order a replacement driveD、Contact IBM Service

考题 An administrator has a single 14U rack.  The administrator needs to install fifteen servers; rack-mounted redundant uninterruptible power supplies (UPSs), a network switch, and a KVM.  Which of the following server types would be BEST suited for this scenario?()A、Blade serversB、Rackmount serversC、Tower serversD、Web servers

考题 When installing a server in a rack, which of the following locations describes where in the rack a server should be installed?()A、On the very bottom U of the rack, with the UPS above the serverB、In the middle of the rack to help balance the rackC、Closest to the bottom of the rack, above heavier equipmentD、On the very top U of the rack, with the UPS directly below it

考题 Which of the following is the MOST important physical consideration when deploying a new server?()A、 Humidity monitors, Biometrics, and fire suppressionB、 Cooling, rack space, and power requirements冷C、 Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD、 Biometrics, fire suppression, and power requirements

考题 Which of the following is the MOST important physical consideration when deploying a new server?()A、Humidity monitors, Biometrics, and fire suppressionB、Cooling, rack space, and power requirementsC、Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD、Biometrics, fire suppression, and power requirements

考题 A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack.  Which IBM BladeCenter Chassis should be recommended? ()A、BladeCenter EB、BladeCenter HC、BladeCenter TD、BladeCenter HT

考题 A customer is considering iDataPlex and several competitive solutions. Which favor iDataPlex of the following?()A、Usable densityB、Lowest cost of acquisitionC、Flexible configurations ready for integration and testing at the customer locationD、Standard rack mounting

考题 A customer is ordering a new p650 server to be placed into an existing OEM 42U 19-inch rack containing only two p630 servers.  This is the first p650 in the enterprise.  What is the most important question that the pSeries technical specialist should ask the customer before the order is placed?()A、Have the PDU requirements been met?B、Are there sufficient KVM connections?C、Is there sufficient service clearance?D、Is there sufficient space in the existing rack?

考题 A customer is considering an Intel processor-based blade solution from a competitor. The customer is willing to share only the information that the competitor offers 96 Xeon processors per rack.  Which of the following IBM BladeCenter E benefits should the Sales Specialist emphasize first?()A、Redundant BlowersB、Availability of AMD and Intel ProcessorsC、Processor densityD、Advanced Management Module

考题 A Dell customer decided to use IBM Director and xSeries to manage their servers.  They purchased 10 IBM x336 servers and they already have 75 various Dell servers.  Which TWO steps need to be verified to be able to manage the mixed environment with IBM Director?()A、Verify that the Dell systems have TCP/IP enabledB、Verify that the systems are running the IBM Director AgentC、Verify that the managed systems are SMBIOS 2.1 and WfM 2.0 compliantD、Verify that the Dell systems have at least a 1GB of memory installedE、Install an SNMP agent on the Dell systems as IBM Director cannot manage Industry Standard non-IBM servers

考题 A customer is looking for a new file and print server and is considering a 2-socket Intel server with redundant power and hard disk that must fit in the current server rack. With 2U available in the rack, the customer is looking for the best price performance ratio.  Which IBM server will fit the best for this customer?()A、x3200B、x3455C、x3550D、x3650

考题 A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()A、Redundant power supplies on the serversB、Redundant PDUs in the rackC、edundant power supplies in the servers and redundant PDUs in the rackD、Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)

考题 A customer is searching for a new, small business server. The customer is standardized on AMD and does not want to place the new server in a rack.  Which IBM server will best fit this customers requirement? ()A、x3105B、x3200C、x3400D、x3455

考题 A customer is running a number of non-IBM servers purchased two years ago and has settled on one of the new IBM xSeries servers as a migration path.  From the following options, which is the preferred migration path?()A、Copy the image of the non-IBM servers and copy that image to the IBM servers, then reboot the IBM servers.B、Copy the image from the non-IBM servers with RDM and install them with IBM Director to the new IBM servers. Reboot the IBM servers.C、Install a fresh operating system using ServerGuide, and then install the applications and copy the data from the old servers.D、Install a fresh operating system on the IBM servers and then run ServerGuide on the IBM servers to migrate the applications and data to the IBM servers.

考题 Which IBM storage products allows for 960 TB (raw) in one standard IBM rack of the following?()A、XIV systemB、DS5300C、DS8800D、Storwize V7000

考题 An administrator needs to install a 2U server into a rack. Which of the following shows how much space, in height, needs to be available for the server to fit in the rack?()A、1.75 inches(4.45 cm)B、2.5 inches(6.35 cm)C、3.5 inches(8.89 cm)D、4.25 inches(10.8 cm)

考题 单选题A customer purchased a new IBM xSeries x445.  They already have a non-IBM industry standard rack with 14U of open space that is being considered to house the new server.  The rack houses an existing UPS unit for the entire rack.  Which of the following questions is most important to ensure that the power in the datacenter environment is ready for the initial install?()A Have optional Fibre Channel and Ethernet switches been installed in the server?B What is the available kVA value of the UPS?C Are there sufficient empty socket outlets in the UPS?D What is the impact on the power consumption of the data center cooling system?

考题 单选题When installing a server in a rack, which of the following locations describes where in the rack a server should be installed?()A On the very bottom U of the rack, with the UPS above the serverB In the middle of the rack to help balance the rackC Closest to the bottom of the rack, above heavier equipmentD On the very top U of the rack, with the UPS directly below it

考题 单选题Which of the following is the MOST important physical consideration when deploying a new server?()A  Humidity monitors, Biometrics, and fire suppressionB  Cooling, rack space, and power requirements冷C  Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD  Biometrics, fire suppression, and power requirements

考题 单选题A customer is searching for a new, small business server. The customer is standardized on AMD and does not want to place the new server in a rack.  Which IBM server will best fit this customers requirement? ()A x3105B x3200C x3400D x3455

考题 单选题A customer is ordering a new p650 server to be placed into an existing OEM 42U 19-inch rack containing only two p630 servers.  This is the first p650 in the enterprise.  What is the most important question that the pSeries technical specialist should ask the customer before the order is placed?()A Have the PDU requirements been met?B Are there sufficient KVM connections?C Is there sufficient service clearance?D Is there sufficient space in the existing rack?

考题 单选题A customer is looking for a new file and print server and is considering a 2-socket Intel server with redundant power and hard disk that must fit in the current server rack. With 2U available in the rack, the customer is looking for the best price performance ratio.  Which IBM server will fit the best for this customer?()A x3200B x3455C x3550D x3650

考题 单选题Which IBM storage products allows for 960 TB (raw) in one standard IBM rack of the following?()A XIV systemB DS5300C DS8800D Storwize V7000

考题 多选题A customer is planning to implement a new x445 in their datacenter.Which TWO of the following should the customer prepare prior to the implementation to ensure a trouble free installation?()AInstall the exhaust fan on top of the IBM NetBAY 42 Enterprise rack for extra coolingBEnsure a 260V power source for the x445 and BladeCenter is available for fully redundant powerCEnsure a 220v power source for the x445 is available for fully redundant powerDInstall the new 10GBit Ethernet network to take advantage of the new network switch in the x445.EHave their Network Operation Staff review and assist connecting the new server to their existing network.