网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

A p5 570 12 way was purchased with the plan to install six LPARs running AIX 5.2. The machine has 12 disks spread evenly over the internal server drawers. The customer would now like to add a seventh LPAR. Which of the following should be added for the seventh LPAR boot device?()

  • A、An additional 7311-D10 drawer
  • B、An adapter to boot off a SAN device
  • C、An additional disk to the media bay
  • D、Two disks to the internal configuration

参考答案

更多 “ A p5 570 12 way was purchased with the plan to install six LPARs running AIX 5.2. The machine has 12 disks spread evenly over the internal server drawers. The customer would now like to add a seventh LPAR. Which of the following should be added for the seventh LPAR boot device?()A、An additional 7311-D10 drawerB、An adapter to boot off a SAN deviceC、An additional disk to the media bayD、Two disks to the internal configuration” 相关考题
考题 Astateagencyhasrecentlydeployedanewapplicationonan8-wayp5-570thatiscriticaltotheagency’soperation.Thereisnomanualmethodtoperformthebusinessprocess.Thestategovernmenthasjustmandatedthatallstateagencieshavedisasterrecoveryplansthatallowtheagenciestorecovercriticalapplicationsinacceptableperiodsoftimewithnolossofperformance.Basedonthisnewbusinessrequirement,whatisthisagencymostlikelytoneed?()A.HACMPandfourprocessorsforthep5-570B.HACMPandeightprocessorsforthep5-570C.HACMP-XDanda4-wayp5-570inasecondlocationD.HACMP-XDanda8-wayp5-570inasecondlocation

考题 Acustomerrequiresan8-way16GBAIXsystem.Theyareevaluatingthefollowingthreesystems:?p5-570?p5-570Express?p650ThepSeriestechnicalspecialisthasbeenaskedtoexplaintheprosandconsofthethreesolutions.Whatinformationwillhelpthecustomerdecideonthebestsolutionfortheirenvironment?()A.Thep5-570ExpresscansupportDDR2memory.B.Thep650andp5-570Expressprovidefasterprocessors.C.Thep5-570Expressislimitedtoeight1.5GHzprocessors.D.Neitherthep5-570northep5-570ExpresssupportsCapacityonDemand.

考题 AcustomerneedsanOracleDatabaseServer.Basedonthecustomer’ssizingdata,theIBMOracleCompetencyCenterhasdeterminedthattheserverrequirementscanbemetwitha4-wayp5-550ora4-wayp5-570.IfthepSeriestechnicalspecialistproposesap5-570versusap5-550system,whatkeydifferencesshouldbepointedouttothecustomer?()A.Thep5-570israckmountedbutthep5-550isnot.B.Thep5-570willprovidemoregrowth,butatahighercost.C.Thep5-570is200-240voltonlyandthep5-550is110voltonly.D.Thep5-570needsaspecialfeaturetobecomeadesksidemachine.

考题 Acustomerneedsthree2-wayapplicationserversandisevaluatingthepurchaseofthreep5-520sversusonepartitioned6-wayp5-570.Theylikethebenefitsprovidedwithdynamicprocessorsparing.WhatinformationshouldthepSeriestechnicalspecialistemphasizetothecustomer?()A.Thep5-570offersCoDprocessors.B.Thep5-570requiresmorerackspacethanthethreep5-520s.C.Redundantpowerisstandardonthep5-570andisoptionalonthep5-520.D.Operatingsystemchargeswillbelessexpensivewiththep5-520solution.

考题 滚动轴承代号为62305/P5;各部分的含义是:“6”表示();“23”表示(); “05”表示();P5表示()。

考题 Companycom has a requirement to consolidate six web application servers. There is unused capacity of 2 CPUs on their new p5 570. Which operating systems and or features are required?()A、APV, AIX5.2ML4B、AIX5.3 or i5/OSC、APV, i5/OS, AIX5.3D、APV, AIX5.3 or SuSE9

考题 Companycom is buying an application solution that bases its software licensing on the number of CPUs per machine. They will be running two instances of this application and will require 8 CPUs each. A second application is priced based on CPUs per LPAR as well as the class of machine. That application will require 8 CPUs. What is the best hardware to propose to keep the software cost low?()A、A 24 way p5 595 with 3 LPARsB、A 24 way p5 595 with 2 LPARsC、One p5 570s 16 way and one p5 570 8 wayD、One p5 595 12 way active and 12 way inactive, and one p5 570 8 way

考题 Companycom recently ordered a p5 570 and an HMC. Prior to delivery, two additional p5 570 servers were added to the order. Upon installation, the system administrator noticed that they do not have a method to connect the p5 570 servers to the HMC. Which of the following will allow them to connect all servers to the HMC?()A、An 8-port adapter to the HMCB、A hub for the private networkC、An additional Ethernet card to the HMCD、An additional Ethernet card for each partition

考题 A p5 570 customer is currently running AIX 5.3. The customer now wants to add Virtual Ethernet to two of the LPARs. This will enable the application tier can communicate to the database tier without using an external Ethernet card. What is the best way to accomplish this task?()A、Create a VIO serverB、Modify the LPAR profiles to add a Virtual Ethernet adapterC、Buy the Advanced Power Virtualization feature and enter a authorization code at the HMCD、Buy the Advanced Power Virtualization feature and enter a authorization code at the service processor menu

考题 Companycom is considering a partitioned solution which will require cumulative rPerf total of 150. The original sizing came back recommending a 32-way p5 590. However, they have a requirement for future scalability and availability is important. Which of the following would be the best reason to recommend a p5 595?()A、The p5 595 would allow for CODB、The p5 595 includes the Advanced Power Virtualization hardware and softwareC、The p5 595 is priced the same as the p5 590 given the same number/type of CPUsD、The p5 595 performance would be equivalent to the p5 590 given the same number/type of CPUs

考题 Companycom has several CR3 HMCs managing their p690 servers. They have purchased a new p5 570 and would like to manage the new system with an existing HMC. What is required to support this environment?()A、Free up one HMC and update the software for use with the p5 570B、Connect the new p5 570 server to an existing HMC and manage the p690s and p5 570 from that HMCC、Order a new HMC to support the new p5 570 server since the CR3 HMC is not supported for a p5 570D、Backup the HMC to DVD-RAM and select HMC migrate to move all the profile data to the new HMC software

考题 A customer needs detailed information on the internal architecture of the new p5-570.  Which of the following is the most appropriate place to get this documentation?()A、IBM sales manualB、IBM Redbooks WebsiteC、IBM eServer p5 and pSeries Qs and AsD、IBM eServer p5 and pSeries Facts and Features

考题 A client has an existing Logical Partition (LPAR) on a p650 running AIX 5.2 and will be porting this LPAR to a p5 590. A mksysb has been run to tape, and a compatible tape drive is available and allocated to the target LPAR on the p5 590. What additional resource needs to be available on the p5 590?()A、A CD or DVD with installation mediaB、An internal SCSI adapter in the target LPARC、An Ethernet adapter for access to an FTP serverD、Advanced Power Virtualization feature of the p5 590

考题 Companycom has a Linux LPAR on a p5 570 server. The 3rd party storage subsystem devices are not supported by Linux. How would access be provided to the storage subsystem devices for this Linux LPAR?()A、Daisy chain the unsupported 3rd party storage subsystem devices with the local SCSI disk drive B、Assuming the 3rd party storage subsystem has AIX support, enable access through a Virtual IO Server C、Assuming the 3rd party storage subsystem has AIX support, implement the Linux partition within an AIX partition D、3rd party storage is not an option for p5 570 servers and therefore only IBM disk subsystems can be considered as a solution

考题 Companycom purchased a p5 570 with no plans to partition. The customer plans to use the ASMI interface to power on and off the machine. How can ASMI be accessed without a HMC?()A、By typing diags and then going to the ASMI menusB、Through SSH from a TCP/IP connection on the serverC、Through WebSM which is connected to a system Ethernet portD、By connecting through a web browser to an HMC Ethernet port

考题 A client has an existing p5 570 that is directly connected to a HMC. The customer will be purchasing another p5 570. Which of the following solutions would be appropriate to provide HMC connectivity to the second p5 570?()A、Implement a proxy server to provide multiple sources to one destination B、Purchase an additional Ethernet adapter for each p5 570 to provide connectivity between the two C、Purchase a network hub or switch so both p5 570s can connect to the single HMC D、Purchase an additional HMC since multiple HMC are required when more than one POWER5 Enterprise class server is used Purchase an additional HMC since multiple HMC? are required when more than one POWER5 Enterprise class server is used

考题 A hosting company recently purchased an IBM p5-570 to use in their data center. The company intends to use the server to run several different client workloads. Which of the following features of the IBM p5 servers addresses the need for the isolation of workloads?()A、Workload ManagerB、Support for AIX 5.3C、Logical partitioningD、64-bit or 32-bit kernel support

考题 Companycom wants to buy a new p5 570 running AIX 5.3. The applications require 4 processors and 8GB of memory. There is a requirement to have a Virtual IO Server. What is the smallest p5 570 that should be sold to this customer?()A、4 processors 8GB of memoryB、5 processors 8GB of memoryC、4 processors 10GB of memoryD、5 processors 10GB of memory

考题 Which server houses the database partitions in the AIX BCU V2.1? ()A、 IBM System p5 570  B、 IBM System p5 575  C、 IBM System p5 590  D、 IBM System p5 595

考题 机组氧气瓶压力在()可看到压力指示。A、DUSB、P5后顶板C、P5前顶板D、CDU

考题 单选题Companycom wants to buy a new p5 570 running AIX 5.3. The applications require 4 processors and 8GB of memory. There is a requirement to have a Virtual IO Server. What is the smallest p5 570 that should be sold to this customer?()A 4 processors 8GB of memoryB 5 processors 8GB of memoryC 4 processors 10GB of memoryD 5 processors 10GB of memory

考题 单选题When doing the Solution Assurance for a p5 570 with several LPARs, it is discovered that the customer plans to back the system up using mksysb. The customer would like to do unattended automated system backups and incorporate them into their off-site data recovery system. Which mksysb solution should be implemented?()A A local DVD-ROM driveB A NFS mount on a NIM MasterC A SSA disk array and mirror the dataD A local tape drive and use DLPAR to move the tape to each LPAR

考题 单选题Which server houses the database partitions in the AIX BCU V2.1? ()A  IBM System p5 570  B  IBM System p5 575  C  IBM System p5 590  D  IBM System p5 595

考题 单选题One of the key decision making factors in a very competitive opportunity will be cost. Companycom needs an aggregate rPerf rating of 120. What is the best solution?()A Two p5 570 16 way 1.9 MHz machinesB One p5 590 32 way 1.65 MHz machinesC One p5 595 32 way 1.65 MHz machinesD Two p5 570 16 way 1.65 MHz machines

考题 单选题Companycom recently ordered a p5 570 and an HMC. Prior to delivery, two additional p5 570 servers were added to the order. Upon installation, the system administrator noticed that they do not have a method to connect the p5 570 servers to the HMC. Which of the following will allow them to connect all servers to the HMC?()A An 8-port adapter to the HMCB A hub for the private networkC An additional Ethernet card to the HMCD An additional Ethernet card for each partition

考题 单选题A customer plans to purchase a p5-570 that will run in SMP mode to host a large financial database on AIX 5.2.  The application is sized for an 8-way 1.65-GHz machine.  They do not currently have an existing HMC that supports p5 machines. This organization experiences unpredictable short-term spikes in processor utilization.  To mitigate the risk to their business, they are interested in IBM’s CoD offering.  In addition to the 8-way system, what else should the pSeries technical specialist recommend to the customer?()A Another p5-570 building blockB Capacity Backup p5-570 building blockC Another p5-570 building block and at least one HMCD Capacity Backup p5-570 building block and at least one HMC

考题 单选题Companycom purchased a new p5 570 without a HMC. The customer does not know how to power the full frame/system off since there does not appear to be an on/off button. What can be done to accomplish this task?()A Telnet into the machine and do a shutdown -FrB Log into ASMI as Administrator and use ASMI menusC Log into the service processor using WebSM and use ASMI menusD Use the off button which is located to the left below the LEDs