网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Voltage generated by most AC generators is fed from the machine to the bus by means of().
A

brushes on a commutator

B

brushes on slip rings

C

slip rings on a commutator

D

direct connections from the stator


参考答案

参考解析
解析: 暂无解析
更多 “单选题Voltage generated by most AC generators is fed from the machine to the bus by means of().A brushes on a commutatorB brushes on slip ringsC slip rings on a commutatorD direct connections from the stator” 相关考题
考题 ( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators

考题 The upper piston rings m large, slow-speed, two-stroke/cycle diesel engines are most effectively lubricated by oil ____.A.fed from mechanical lubricatorsB.thrown off from the main bearingsC.supplied from wick fed drip lubricatorsD.flow from a centrifugal or banjo oiler

考题 A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?() A. MultimeterB. OscilloscopeC. Cable testerD. Power supply tester

考题 Equal power factors on paralleled AC generators are maintained by an automatic ________.A.governor control switchB.reverse power relayC.reverse current relayD.voltage regulator

考题 While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are______.A.running at the same speedB.groundedC.of the same polarityD.in phase

考题 The ASBR-summary LSA is:().A、Generated by the ASBR and describes reachability to itselfB、Generated by the ASBR and describes reachabilty to the ABRC、Generated by the ABR and describes reachabilty to the ASBR for routers in a different area from the ASBRD、Generated by the ABR and describes reachabilty to the ASBR for routers in the same area with the ASBR

考题 A military member has just returned to the United States from Europe and reports their personaldesktop computer does not work. Which of the following is the MOST logical solution to thisproblem?()A、The computer is unable to work in the US because of EU licensing arrangementsB、The power supply needs to be replaced with one rated for 110 wattsC、The power supply needs a power inverter to handle the change in cyclesD、The power supply voltage needs to be switched to 110 from 220

考题 A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?()A、MultimeterB、OscilloscopeC、Cable testerD、Power supply tester

考题 单选题()on board ship are used to control and distribute the electrical energy generated by generators.A GovernorsB AlternatorsC BlackboardsD Switchboards

考题 单选题The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ().A droopB dropC dipD regulation

考题 单选题Which is a function of the voltage regulators used with AC generators?()A To cut out generators when they are no longer requiredB To cut in additional generators automatically as requiredC To divide the KW load equally between generators operating in parallelD To divide reactive current between generators operating in parallel

考题 单选题Generators should have an excitation/voltage regulation system which will enable them to share the steady state reactive load () no machine exceeds its proportional share of reactive load by more than 10% of the rated reactive load of the largest generator.A whenB so asC such thatD though

考题 单选题AC voltmeters are generally calibrated to read the ()A instantaneous voltageB average voltageC RMS voltageD peak voltage

考题 单选题While paralleling two AC generators using synchronizing lamps only, both lamps will go dark when the generators are ().A running at the same speedB groundedC of the same polarityD in phase

考题 单选题Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the ()A manual positionB bus neutral positionC raise voltage positionD transfer position

考题 单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().A is smallB may be neglectedC is usefulD is considerable

考题 单选题The most inefficient method of voltage reduction from the stand point of power loss, is a/an ()A capacitor in series with the loadB inductor in series with the loadC capacitor and inductor in series with the loadD resistor in series with the load

考题 单选题A military member has just returned to the United States from Europe and reports their personaldesktop computer does not work. Which of the following is the MOST logical solution to thisproblem?()A The computer is unable to work in the US because of EU licensing arrangementsB The power supply needs to be replaced with one rated for 110 wattsC The power supply needs a power inverter to handle the change in cyclesD The power supply voltage needs to be switched to 110 from 220

考题 单选题When paralleled, AC generators must have the same ()A frequencyB number of phasesC phase rotationD All of the above

考题 单选题When two DC generators operate in parallel, they are protected against motorizing by()A blow out coilsB governor relayC under voltage tripsD reverse current trips

考题 单选题If two AC generators are operated in parallel, the load is distributed evenly by()A a rheostatB a balancing coilC changing field excitationD adjusting the governor settings

考题 单选题The most common source of excitation for synchronous motors is a/an ().A low voltage batteryB motor attenuator setC DC exciter generatorD AC supply

考题 单选题AC and DC generators are similar in that they ()A both generate alternating voltagesB both rectify the voltage before deliveryC are constructed at the same physical size for the same kilowatt ratingD both supply three-phase power

考题 单选题The number of cycles per second occurring in AC voltage is known as the ()A phase angleB frequencyC wave formD half mode

考题 单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()A slightly less than the oncoming generator frequencyB the same as the bus frequencyC slightly greater than the bus frequencyD the same as the bus voltage

考题 单选题The voltage developed by an AC generator is controlled by varying the ()A speed of the prime moverB AC excitation to the fieldC DC excitation to the fieldD DC excitation of the voltage regulator

考题 单选题A constant output voltage from an AC generator is maintained by the ().A prime mover governorB exciter generatorC voltage regulatorD reverse power relay