网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()
A

 It has a GUI interface for upgrading system firmware. 

B

 It creates and manages AIX/Linux and VIOS type LPARs. 

C

 It can be managed by the Hardware Management Console (HMC). 

D

 It supports Live Partition Mobility on POWER6 systems and above.


参考答案

参考解析
解析: 暂无解析
更多 “单选题Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A  It has a GUI interface for upgrading system firmware. B  It creates and manages AIX/Linux and VIOS type LPARs. C  It can be managed by the Hardware Management Console (HMC). D  It supports Live Partition Mobility on POWER6 systems and above.” 相关考题
考题 On which product media can the IVM install code be located?() A.Base AIX Install media.B.Base VIOS Install media.C.AIX Expansion Pack media.D.VIOS Expansion Pack media.

考题 On which product media can the IVM install code be located?()A、Base AIX Install media.B、Base VIOS Install media.C、AIX Expansion Pack media.D、VIOS Expansion Pack media.

考题 A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A、 The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B、 The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C、 Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D、 Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).

考题 Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A、AIXB、IBM iC、LinuxD、VIO Server

考题 Which of the following functions can be performed using the Integrated Virtualization Manager?()A、Concurrent firmware updatesB、Management of virtual storageC、Hot add/remove of I/O drawersD、Management of Capacity on Demand

考题 Company.com is running a p5-550 system with inactive processors. The system is managed using the Integrated Virtualization Manager. How would the system administrator activate two additional processors?()A、Use the Advanced Systems Management Interface to enter the Capacity on Demand Enablement code.B、Use the Web-based System Manager Interface to enter the Capacity on Demand enablement code.C、Use smitty or smit interface to enter the Capacity on Demand enablement code.D、Use oem_setup_env on the Virtual I/O Server to enter the Capacity on Demand enablement code.

考题 A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications.   The pSeries technical specialist should recommend purchasing which of the following?()A、p5 hardware, AIX 5.2, Virtual I/O ServerB、POWER4 hardware, AIX 5.3, Virtual I/O Server,C、p5 hardware, AIX 5.3, Advanced POWER Virtualization featureD、POWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature

考题 A system administrator has just finished upgrading a system to AIX 5.2. If there are future problems, the system administrator would like to add an entry to the AIX errorlog to record this event. Which of the following commands can be issued for this purpose?()A、/usr/bin/errmsg "System upgraded to AIX 5.2"B、/usr/bin/errlog "System upgraded to AIX 5.2"C、/usr/bin/errupdate "System upgraded to AIX 5.2"D、/usr/bin/errlogger "System upgraded to AIX 5.2"

考题 Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()A、Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. B、The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. C、If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. D、The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot. 

考题 A Power 720 has AIX 6.1 and Linux partitions.During normal workloads there is more than enough memory available to the LPARs.  During month-end processing one partition becomes memory constrained.      What can help overcome this situation?()A、Active Memory Sharing (AMS)B、Active Memory Expansion (AME)C、Integrated Virtual Memory (IVM)D、Memory Capacity on Demand (CoD)

考题 Which of the following interfaces is required to implement Workload Partition Mobility? ()A、 Workload Partitions Manager for AIXB、 Hardware Management Console (HMC) GUIC、 Integrated Virtualization Manager (IVM)D、 Advanced System Management Interface (ASMI)

考题 Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A、AIXB、IBMiC、LinuxD、VIO Server

考题 A data center includes a Power 750 server running AIX and Linux, and PS700 Blades running AIX. What can the customer use to update AIX and Linux, create and deploy LPARs, and set energy caps for both servers from a single console?()A、PowerVM Standard EditionB、VMControl Standard EditionC、Hardware Management ConsoleD、IBM Systems Director Standard Edition

考题 Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A、 It has a GUI interface for upgrading system firmware. B、 It creates and manages AIX/Linux and VIOS type LPARs. C、 It can be managed by the Hardware Management Console (HMC). D、 It supports Live Partition Mobility on POWER6 systems and above.

考题 单选题Company.com is running a p5-550 system with inactive processors. The system is managed using the Integrated Virtualization Manager. How would the system administrator activate two additional processors?()A Use the Advanced Systems Management Interface to enter the Capacity on Demand Enablement code.B Use the Web-based System Manager Interface to enter the Capacity on Demand enablement code.C Use smitty or smit interface to enter the Capacity on Demand enablement code.D Use oem_setup_env on the Virtual I/O Server to enter the Capacity on Demand enablement code.

考题 单选题Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A  The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B  The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C  Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D  Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).

考题 单选题Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()A Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. B The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. C If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. D The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot. 

考题 单选题A system administrator has just finished upgrading a system to AIX 5.2. If there are future problems, the system administrator would like to add an entry to the AIX errorlog to record this event. Which of the following commands can be issued for this purpose?()A /usr/bin/errmsg System upgraded to AIX 5.2B /usr/bin/errlog System upgraded to AIX 5.2C /usr/bin/errupdate System upgraded to AIX 5.2D /usr/bin/errlogger System upgraded to AIX 5.2

考题 单选题Which of the following functions can be performed using the Integrated Virtualization Manager?()A Concurrent firmware updatesB Management of virtual storageC Hot add/remove of I/O drawersD Management of Capacity on Demand

考题 单选题Which of the following interfaces is required to implement Workload Partition Mobility? ()A  Workload Partitions Manager for AIXB  Hardware Management Console (HMC) GUIC  Integrated Virtualization Manager (IVM)D  Advanced System Management Interface (ASMI)

考题 单选题Which of the following is a management strategy of iDataPlex?()A IBM Systems Director manages all components as single imageB Rack Management Appliance manages the homogeneous imageC HMC manages dissimilar componentsD Tivoli Provisioning Manager (TPC) manages all components as single image

考题 单选题Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A AIXB IBMiC LinuxD VIO Server

考题 单选题A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications.   The pSeries technical specialist should recommend purchasing which of the following?()A p5 hardware, AIX 5.2, Virtual I/O ServerB POWER4 hardware, AIX 5.3, Virtual I/O Server,C p5 hardware, AIX 5.3, Advanced POWER Virtualization featureD POWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature

考题 单选题Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A AIXB IBM iC LinuxD VIO Server

考题 单选题Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A  It has a GUI interface for upgrading system firmware. B  It creates and manages AIX/Linux and VIOS type LPARs. C  It can be managed by the Hardware Management Console (HMC). D  It supports Live Partition Mobility on POWER6 systems and above.

考题 单选题The Virtualization Manager manages physical and virtual machines through a single console.  Which vendor offers this product to its customer at no additional charge?()A HPB UnisysC DELLD IBM

考题 单选题A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A  Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B  Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C  Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D  Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.